1. Introduction
Please read this guide carefully and retain for future use and maintenance.
The CRXSL Wireless Controller can control all ‘RX’ and ‘SL’ products.
If the CRXSL is controlling ‘SL’ products the following functions are not available:
Reduced heat output
Fan function
The CRXSL can control multiple ‘RX’ and ‘SL’ products at the same time.
An illustration of functions available on CRXSL
2. Getting to know your CRXSL wireless controller

2
I3984093 Iss 01
3. Pairing CRXSL with heaters
This must be done, otherwise the heaters will not work.
Power up the CRXSL (see section ‘Power options’ for details).
There are 2 different sequences used for pairing. The sequence
used will depend on the heater.
To find out which sequence to use, check the heater rating
label and identify the model number.
If the heater is ‘RX’ and the last two digits are lower than 10 use
sequence 1.
If the heater is ‘RX’ and the last two digits are 10 or higher use
sequence 2.
If the heater is ‘SL’ use sequence 2.
If the rating label is not visible, follow the steps below:
Ensure the heater is switched OFF.
Switch the heater ON and observe the LED status light.
If the LED flashes red then goes green use sequence 1.
If the LED is solid green use sequence 2.
Sequence 1
Set heater into pairing mode as follows:
1. Locate the heater LED status light.
2. Turn power to the heater ON. Count 4 seconds, or
count 5 red flashes of the status light on the heater.
Turn power OFF.
3. Turn power back ON. The heater status light should
be flashing green.
(If the light is not flashing green, the 4 second timing
was incorrect. Repeat step 1.)
4. The heater is now ready for pairing with CRXSL.
The next 3 steps must be done within 30 seconds. After 30
seconds the heater will return to normal operating mode. Set
the CRXSL into pairing mode as follows:
1. Touch and hold and icons together for 5
seconds.
2. The display will show CRXSL identification code.
3. Touch the button while the light on the heater is
flashing green.
If the pairing was successful, the light will stop flashing and the
heater is paired with CRXSL. This has to be done within 30
seconds. After 30 seconds, the CRXSL will return to normal
operating mode.
Sequence 2
Set heater into pairing mode as follows:
1. Locate the heater status light.
2. Turn power to the heater ON. The light should be
solid green.
The next step must be done within 20 seconds. After 20
seconds, the heater will return to normal operating mode.
Set the CRXSL into pairing mode as follows:
1. Touch and hold and icons together for 5
seconds.
2. The display will show CRXSL identification code.
3. Touch the button and the CRXSL will beep & flash
3 times.
3. Pairing CRXSL with heaters (cont’d)
If the pairing was successful, the light will show red and
the heat output will switch on and stay on if the CRXSL is
signalling the heat output to be on. If the CRXSL is
signalling the heat output to be off, the heat output will
only switch on for a short period of time to show pairing
was successful.
4. Basic operation
Before you can use CRXSL, it has to be activated by tapping
any control icons. The LCD screen backlight will turn on. To
operate any control icon, touch within 2 seconds of CRXSL
activation.
5. Time and day setting
1. To enter time setting touch and hold for 5 seconds.
2. The minutes will flash.
3. Use or to set minutes.
4. Touch , the hours will flash.
5. Use or to set hours.
6. Touch , the MON will flash.
7. Use or to select day.
8. Once you are happy with the settings, leave the CRXSL
for 20 seconds. The settings will be saved and CRXSL will
return to the main screen.
6. Selecting operating mode
CRXSL has 4 operating modes:
BOOST, MANUAL, SET BACK and PROGRAM.
Each mode can be selected by activating the CRXSL and
tapping to cycle through the options. The cycle sequence
will always start with BOOST mode followed by MANUAL, SET
BACK and PROGRAM.
7. MAN - Manual mode
In manual mode, the heater maintains the set temperature.
1. Touch or to set the temperature.
To amend the set temperature, tap any control button once
to activate, then touch or to change the temperature.
Once the temperature is set, leave the thermostat and the
settings will be saved.
8. BOOST - 15 minutes
The boost feature temporarily increases the room
temperature. It can be used from any mode.
1. Touch or to set the temperature.
To amend the set temperature, touch any control button
once to activate, then touch or to change the
temperature. Once the temperature is set, you can leave the
thermostat and the settings will be saved. After 15 minutes,
the CRXSL will return to previous operating mode.

3
I3984093 Iss 01
9. PROG - Automatic time mode
In this mode, the CRXSL will follow the week’s time /
temperature programme.
You can override the temperature in PROG mode by simply
activating the CRXSL and using the or icon to set the
new temperature. The new set temperature will be then
maintained until the next program step.
Touch to ADVANCE program, touch again to go back.
Setback mode can be used for frost protection, situations
where a minimum room temperature must be maintained, or
to disable the heating completely .
To set the temperature touch or .When the room
temperature drops below the set temperature the heating
will be active.
To disable heating lower the temperature to below 4ºc and
she screen will show ‘- - -’ The heating is now disable.
10. SETB - Setback mode
11. Set 7-day programme
06:00
10
20
08:00
19ºC
4ºC
ºC
12:00
22ºC
14:00 16:00
16ºC
22ºC
10ºC
22:00
PROGRAM 1 PROGRAM 2 PROGRAM 3 PROGRAM 4 PROGRAM 5 PROGRAM 6
An example of one day programme on CRXSL
-SET HOURS FOR PROGRAM
TIME SETTING PROGRAMME SETTING
-SET MINUTES
-SET DAY
-SET HOURS
-SELECT DAY TO SET
-SET MINUTES FOR PROGRAM
-SELECT PROGRAM TO SET
-SET TEMPERATURE FOR PROGRAM
11. Set 7-day programme (cont’d)
Logic diagram for setting programme on CRXSL
11. Set 7-day programme (cont’d)
The CRXSL has a 7-day timer with up to 6 programming steps
available for each day. In the programming you can set a
start time and a temperature for each programme. Each
programme has to be used or set inactive.
1. Touch and hold for 5 seconds to enter the time
setting.
2. The minutes will flash.
3. Touch or to set the minutes.
4. To set hour, touch and the hour will begin to flash.
5. Touch or to set the hour.
6. To set day, touch and the day will begin to flash.
7. Touch or to select the day.
8. Touch to access the 7-day programming mode.
9. Touch or to select the day you want to set.
10. Touch to set programme 1 for selected day.
This is indicated by the flashing number.
11. Touch to select minutes.
12. Touch or to set minutes.
13. Touch to select hour.
14. Touch or to set hour.
15. Touch to select temperature setting.
16. Touch or to set temperature.

4
I3984093 Iss 01
15. Advance mode
Touch from SETB or PROG mode to bring forward next
programme. To clear advance mode, touch .
16. Keys locking
Touch and hold together for 5 seconds. The display will
show symbol. Repeat the step to unlock.
13. Copy day function
The CRXSL allows you to copy a day’s heating programme to
save time re-entering the same time and temperature settings
for a day.
1. To use a copy day function, enter the programming
mode.
2. To skip time setting, touch to cycle through hour and
day.
3. On the next tap, the Programme mode is activated and
the day will flash.
4. Touch to activate the COPY DAY function.
5. Touch to select the day you want to copy the
temperature settings from.
6. Touch or to select the day you want to copy the
temperature settings to.
7. Touch to confirm the selection.
The ‘to’ word will flash to indicate that the day programme
has been copied to the day selected.
8. Touch to go back to the Programme mode.
12. Set programme inactive
To deactivate a programme, enter the programming mode.
Select the programme you want to make inactive and
touch . The time and temperature will now be dashes to
indicate that the programme has been deactivated. In order
to re-activate the temperature setting, touch again.
17. Heat symbol on the display
Every time there is a demand for heat, the display will show
the heat icon.
- Reduced heat output when the room temperature is
close to the set temperature (‘RX’ products only)…..
- Full heat output.
14. Fan function - only available for fan heaters
Touch any control icon to activate the CRXSL touch to
activate or deactivate the fan function.
The CRXSL controller can be powered either by a 5V power
adapter with a micro USB connector, supplied power
adapter via USB port or 4 AAA batteries. There are 2
available USB ports for power. One port is located on the
bottom and one at the back of the controller.
The CRXSL is a wireless thermostat giving high precision room
temperature control. It is also a 7 day programmer with up to
6 temperature settings per day. Each CRXSL can control any
number of heaters in the same room (zone).
The CRXSL controller is compatible with the MRX1 Multizone
controller. Please refer to the instructions of the MRX1 when
connecting the CRXSL controller to the MRX1.
20. Power options
Power options, installation guide and setup menu
19. Choosing a position in a room
The CRXSL should be fixed to the wall or used with the table
top bracket. Avoid areas with draught or direct sun. Do not
position CRXSL above or close to the heaters or other heat
sources. Damp areas or areas where CRXSL can be
mechanically damaged should also be avoided.
18. Status light on the heater
Light colour Heater status
Heater is in stand-by mode/ not
receiving signal from CRXSL.
Reduced heat output (RX only)
Full power heat output
FAULT - Overheating (RX only)
Heater is ready for pairing with
CRXSL see section 3 “Pairing” for
details.
OR
OR
Remove the CRXSL’s battery cover and insert 4 new high
quality alkaline AAA batteries.
Warning: Consort is not responsible for damage due to
corrosion. Battery leakage will cause permanent damage.
Do not use batteries when unit is powered on with mains.
To help avoid battery leak:
Replace the batteries annually, even if there is not a
low battery warning. Remove failing or flat batteries
immediately.
Always fit a pair of new high quality alkaline batteries
from the same pack. Never mix new and old batteries,
or batteries of different brands or types.
Never attempt to revive alkaline batteries by heating,
crushing or recharging.
Note: The clock has to be set after replacing the batteries, or
if the USB power cable has been removed from the CRXSL.
This does not apply if it is being used with the MRX1 Multizone
controller.
21. Batteries

5
I3984093 Iss 01
22. Power adapter for fixed installation
The CRXSL controller is supplied with a power adapter that
will fit a 35mm or a 25mm metal or dry lining back box. The
power adapter should only be connected to a wiring
protected by a 6A fuse or 6A circuit breaker. Connect line
and neutral conductors to the terminal block. Please note
that the adaptor supplied with the controller must be
installed exactly as the figures show, otherwise the USB
connector will not fit correctly. The centre of the back box
must be kept clear to allow room for the USB connector.
When fitting the wall bracket, ensure that the adaptor is
installed properly and feed the cable through the centre of
the bracket. Screw the bracket to a back box taking care
not to damage the power adaptor or leads with long screws.
Connect the USB cable into the power port at back of the
controller as shown on the photo. Check that the CRXSL is
working. Attach top of the CRXSL to the wall bracket and
slowly tilt it to place observing that the USB connector is
moving in to the opening freely. Once the controller is in
place secure the two screws on the bottom of the controller.
Please note that the controller screen will take up to
one minute to display after powering up for the FIRST
time.
23. Open Window Detection
To ensure you don’t waste energy on heating the outside
world, the heater is equipped with optional open /
closed window detection. The heater recognises sudden
drops in temperature when a window or a door is
opened and turns the heating off to save energy. When
the window is closed, the heater will automatically
detect a temperature rise, and switch itself back on.
Once enabled in the setup menu, the open window
detection is fully automatic and does not require any
human intervention to be activated.
Setting-up Open Window Detection
The system has been factory set to default time and
temperature values. If necessary, all values can be
adjusted. When the heating is on, open window
detection sensor will automatically switch the heater off
when it detects a fall in temperature of 2°C in less than
10 minutes (this temperature can be changed in menu 7
and time in menu 6). If a temperature rise of 2°C in less
than 30 seconds is detected, the heater will switch itself
back on (this temperature can be changed in menu 9
and time in menu 8).
24. Setup menu
1. Touch and hold and icons together for 10
seconds.
2. The CRXSL will enter the setup menu.
3. Use and to change a value.
4. Use to scroll between the settings.
01 –temperature calibration
The temperature reading has been factory calibrated but if
for any reason it needs adjusting (better accuracy required,
to suit different position in the room etc.) The reading can be
recalibrated in 0.5 degrees steps.
Please note that if the unit is powered by the power adapter, the
temperature reading REQUIRES recalibration. Lower the value by 1.5
degrees.
02 –change between degrees Celsius or Fahrenheit
03 –set minimum temperature
(- - - = heating OFF, 4deg = frost protection)
04 –set maximum temperature
05 - information about the software version
06 - 0 or 1 manual mode enable / disable
07 - open window detection 0 = off, 1 = on
08 - 600 - open window detection time 600 seconds
09 - 2 - temperature drop of 2°C in the detection time
10 - 30 - closed window detection time of 30 seconds
11 -2 - temperature rise of 2°C in the detection time
22. Power adapter for fixed installation (cont’d)
locking screws
USB power ports
temperature sensor
wall fixing
wall fixing

6
I3984093 Iss 01
The CRXSL is guaranteed for one year against faulty material or workmanship. This applies only if the appliance has
been used for purposes in accordance with the instructions provided and has not been misused, neglected,
damaged, modified or repaired by any person not authorised by us. This guarantee is offered to you as an extra
benefit and does not affect your legal rights.
Reasonable care has been taken to ensure that this guide is accurate at the time of printing. In the interest of
progress, the Company reserve the right to vary specifications from time to time without notice.
Should you need any advice on the use of you new Consort product please contact our Helpline:
Consort Equipment Products Limited
Thornton Industrial Estate, Milford Haven, Pembrokeshire, SA73 2RT
Tel: 01646 692172 | Fax: 01646 695195
Operation hours: Mon to Thu 8.30am to 4.30pm | Fri 8.30am to 3.30pm
BS EN ISO 9001 Registered Company No FM12671
Customer Helpline
Table des matières
Autres manuels Consort Contrôleurs

Consort
Consort SLVTB Manuel d'utilisation et d'entretien

Consort
Consort CRX2-03 Manuel utilisateur

Consort
Consort SLPIR Manuel d'utilisation et d'entretien

Consort
Consort CRXSL-05 Manuel utilisateur

Consort
Consort MRX1 Manuel utilisateur

Consort
Consort SLPBWIFI Manuel d'utilisation et d'entretien

Consort
Consort SLTI Manuel d'utilisation et d'entretien

Consort
Consort HRXSL Manuel d'utilisation et d'entretien

Consort
Consort CRX2 Manuel utilisateur

Consort
Consort CRX1 Manuel utilisateur