Condair MD Series Manuel utilisateur

2603114-B EN 2112
Humidication and Evaporative Cooling
INSTALLATION MANUAL
Condair HumiLife – the efcient ERV solution
Condair MD

Thank you for choosing Condair
Important!
Please enter the system data listed below during commissioning.
Installation date (DD/MM/YYYY):
Commissioning date (DD/MM/YYYY):
Installation site:
Model:
Serial number:
Supply water hardness at the installation site:
Supply water pH value at the installation site:
Proprietary rights
This document and the information disclosed herein are proprietary data of Condair Group AG. This manual (in-
cluding extracts hereof) may not be reproduced or passed on, nor may the contents thereof be used or passed
on to any third party without the written permission of Condair Group AG. Any infringements are punishable and
entail a liability for damages.
Liability
Condair Group AG is not liable for any damages incurred as a result of poorly executed installation, improper
operation or the use of components or equipment not approved by Condair Group AG.
Copyright notice
© Condair Group AG, All rights reserved
Technical modications reserved

3Table of Contents
Table of Contents
1 Introduction 5
1.1 First things rst! 5
1.2 Notes on installation manual 5
2 For your safety 7
3 Product overview 9
3.1 Model overview 9
3.2 Product labelling 9
3.3 System overview Condair MD 10
3.4 Scope of delivery 11
3.5 Options 11
3.6 Accessories 12
4 Checking delivery/storage and transport 13
4.1 Checking delivery 13
4.2 Storage and transport 13
5 Installation overview 14
5.1 Safety instructions for the installation work 14
5.2 Installation overview Condair MD 15
5.3 Requirements for the installation room 16
5.4 Humidier unit mounting 17
5.4.1 Instructions for positioning the humidier unit 17
5.4.2 Insert the base panel and attach the adapters 20
5.4.3 Attach humidier housing to ceiling or wall 21
5.5 Hydraulic unit mounting 25
5.5.1 Instructions for positioning the hydraulic unit 25
5.5.2 Hydraulic unit mounting 25
5.6 Create hose connections between hydraulic unit and humidier unit 27
5.7 Installation of the fresh water supply and water drain 28
5.7.1 Fresh water supply 28
5.7.1.1 Fresh water supply requirements 28
5.7.1.2 When is a Condair RO-HS reverse osmosis system required? 29
5.7.1.3 Installation of fresh water supply 30
5.7.2 Water drain 31
5.8 Installing the heating water 32
5.9 Humidity control 34
5.10 Positioning and installation of the sensors 36
5.10.1 Positioning sensors 36
5.10.1.1 Installation of the humidity and temperature sensor as well as the max. humidistat 37
5.10.1.2 Mounting the airow monitor 37

4Table of Contents
5.11 Electrical installation 38
5.11.1 Notes on electrical installation 38
5.11.2 Condair MD wiring diagram 39
5.11.3 Connection work for external connections 40
5.11.3.1 Connection of the humidity sensor with humidity control via the integrated humidity controller 40
5.11.3.2 Connection of an external controller 0-10 V 41
5.11.3.3 Connection of the optional maximum humidistat in the supply air or extract air duct 41
5.11.3.4 Connection of the optional airow monitor and the optional oor leak sensor 42
5.11.3.5 Connection of the leak sensor of the humidier unit 42
5.11.3.6 Mains connection (mains socket) 43
5.11.4 Cable entry 43
6 Product specications 44
6.1 Technical data of the hydraulic unit 44
6.2 Technical data of humidier unit 45
7 Appendix 46
7.1 Dimensional drawing of humidier unit 46
7.2 Dimensional drawings of adapters 46
7.3 Dimensional drawing of hydraulic unit 47

5Introduction
1 Introduction
1.1 First things rst!
Thank you for choosing the Condair MD.
The Condair MD has been built using state-of-the-art technology and in accordance with the latest safety
regulations. However, improper use of the Condair MD may put users and/or third parties at risk and/or
may also cause damage to material assets.
Please observe and comply with all information and safety instructions in this documentation and in the
instructions to the components built into the humidier system to ensure safe, proper and cost-efcient
operation of the Condair MD.
Should you have any questions after reading these instructions, please contact your local Condair
partner. We will be happy to assist.
1.2 Notes on installation manual
Delimitations
The subject of this installation manual is the Condair MD. Options and accessories are only de-
scribed insofar as is necessary for proper operation. Please see the relevant instructions for additional
information on the options and accessories.
The information in this installation manual is restricted to the installation of the Condair MD and is
aimed at correspondingly trained specialist staff that has been adequately trained for the cor-
responding activity.
This installation manual is supplemented by various separate documentation (operation manual, spare
parts list, etc.), which are also included in the scope of delivery. Where necessary, this installation manual
may refer to these publications.

6Introduction
Symbols used in this manual
CAUTION!
The signal word "CAUTION" together with the hazard symbol in a circle indicates information provided
in this documentation which, if ignored, could lead to damage and/or the failure of the device or
other equipment.
WARNING!
The signal word "WARNING", together with the general hazard symbol, indicates safety and hazard
information given in this documentation which, if ignored, could lead to injury to people.
DANGER!
The signal word "DANGER", together with the general hazard symbol, indicates safety and hazard
information given in this documentation which, if ignored, could lead to serious injury or even death
to people.
Storage
Please keep this installation manual in a safe place where they can be accessed at all times. If the
product changes owner, the installation manual must be handed over to the new operator.
If this installation manual are lost, please contact your Condair partner.
Language versions
This installation manual are available in various languages. For more information, please contact your
Condair partner.

7For your safety
2 For your safety
General information
Any persons assigned to installing the Condair MD must have read and understood the installation
manual as well as the operation manual of the Condair MD before starting work on the unit.
An understanding of the content of this installation manual and the operation manual is a basic pre-
requisite for protecting personnel from danger, avoiding improper installation and operating the device
safely and properly.
All pictograms, signs and labelling applied to the Condair MD must be observed and kept in a clearly
legible condition.
Personnel qualications
All actions described in this installation manual may be performed by trained and adequately qualied
specialist personnel authorised by the operator only.
Furthermore, for safety and warranty reasons, interventions may only be undertaken by specialist per-
sonnel authorised by Condair.
It is assumed that all persons entrusted to work on the Condair MD are familiar with and abide by the
regulations on occupational health and safety and accident prevention.
Intended use
The Condair MD is exclusively intended for duct air humidication together with Energy Recover
Ventilation (ERV) within the specied operating conditions. Any other use without the written
permission of Condair is deemed to be improper use and can render the Condair MD hazardous. Any
unintended use shall render guarantee claims void.
Intended use also includes the following: observing all information contained in this documentation
(particularly all safety and hazard warnings).
Danger that may arise from the device:
DANGER!
Risk of electrocution!
The hydraulic unit of the Condair MD operates using mains voltage. If the hydraulic unit is open,
users may come into contact with live parts. Touching live parts may cause severe injury or death.
For this reason: Do not connect the Condair MD hydraulic unit to the power supply until all installation
work has been completed, all installations have been checked for correct operation and the hydraulic
unit has been correctly closed and locked again.

8For your safety
Avoidance of hazardous operating conditions
All persons entrusted to work on the Condair MD are obliged to report to the appropriate ofce or person
representing the operator on any changes to the system that affect safety, and secure the Condair MD
against being switched on accidentally.
Unauthorized modications to the device
No additions or modications must be made to the Condair MD without the written permission of Condair.
When replacing any defective components on the unit, use only genuine accessories and spare parts
provided by your Condair partner.

9Product overview
Condair Group AG, Gwattstrasse 17, 8808 Pfäfkon SZ, Switzerland
Type: Condair MD Serial no.: XXXXXXX 11.19
Voltage: 230V/1~/50-60Hz El. output: 800.0 VA 3.4 A
Humidier output: 2 kg/h
Water pressure: 1.5 to 5 bar, <30°C Code: MD-EL-2HE
Engineered in Switzerland, made in Germany
3 Product overview
3.1 Model overview
The Condair MD consists of a hydraulic unit and a humidier unit for installation in horizontal ventila-
tion ducts and has a maximum humidication output of 2 kg/h. The humidication water is heated via
the integrated heat exchanger, which is connected to the heating water system (35 ° C… 60 ° C) of a
connected to a oor/wall-based heating system with a circulation pump or a convection circuit with a
circulation pump.
Note: The stated humidication output is the maximum value, measured at an air throughput rate of
180 m3/h. The effective humidication output depends on the heating source output, the condition of the
supply air and the adjusted humidity setpoint. The output has been veried by Fraunhofer Institute for
Solar Energy Systems (ISE), Freiburg, Germany.
The functionality of the Condair MD can be enhanced using various options. Different accessories and
consumables are also available.
3.2 Product labelling
The type plate features the product labelling:
Type designation Serial number (7 digits)
Production date,
month/year
Connection voltage
Maximum humidication output
Permissible water connection pressure
Electrical output
Field with test marks
Variant code

10 Product overview
3.3 System overview Condair MD
Fig. 1: System overview Condair MD
1Fresh water supply shut-off valve
2Water treatment (optional)
3Fresh water supply connection
4Drain connection
5 Drain funnel with siphon
6Service uid connection
7 Humidier unit supply
8 Humidier unit return
9 Hydraulic unit
10 Mains connection cable
11 Mains socket (230V/1~/50Hz)
12 Mains connection adapter CH
13 Humidier unit
14 Humidity sensor with humidity limitation
15 Air ow monitor
16 Maximum humidistat supply or extract air duct (optional)
17 Energy recovery ventilation (ERV)
18 Heating water supply connection
19 Heating water return connection
20 On-site heating water installation
17
13
16 14
17
12
10
11
16
20
5
3 4
1
2
9
18 19
6
8
7
15
Abluft
Zuluft
Water treatment (optional)
Reverse osmosis system
Condair RO-HS
Supply and return of
existing oor/wall-
based heating or
convection circuit
Autres manuels pour MD Series
7
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Condair Ventilateur