Compass G1000i Manuel utilisateur

G1000i Inverter Generator
User’s manual
Please read the manual carefully before using the generator.
This guide contains important guidance for safe operation.

G1000i Inverter Generator
2
Preface
Thank you for buying Inverter Generator.
This book includes the operation and maintenance instructions for the G1000i.
All the contents of this book are consistent with the print of the latest product.
The Company retains its right to amend this guide, thus will not notify later or
bear any responsibility.
o duplicator is permitted without written permission.
As one permanent part of the generator, the guide will be kept with the generator
when the machine is transferred.
Please pay special attention to the following words:
Warning
This sign indicates that if you do not operate according to the guide,
serious accidents involving casualties can be caused.
ook Out
This sign indicates that if casualty is caused or the equipment is
damaged by incorrect operation, you can contact your reseller if you have any
questions about the generator.
Note:
Give useful information.
If there is any failure of the generator, or if you have any questions about it,
please consult your reseller.
Warning
As long as you operate according to the guide, the G1000i generator
will be safe and reliable. Please read and understand the guide without fail
before you use it, or else casualties or damage of the equipment will be caused
by incorrect operation.
Different types of generators may have some differences in their guides.

G1000i Inverter Generator
3
Catalogue
1. Safety matters
2. Label position of safety matters
3. Components identifier
4. Check before operation
5. Start the engine (operation at high altitudes)
6. Usage
7. Turn off the engine maintenance
8. Transport/storage
9. Examine and repair the breakdown
10. Technical specification
11. Wiring diagram

G1000i Inverter Generator
4
1. Safety Matters
To ensure safe operation matters
Warning
If you operate the G1000i generator according to the guide, the generator
will run safely. Please read and understand the guide without fail before you use
it, or else casualties or damage of the equipment will be caused by incorrect
operation.
Warning
The exhaust contains toxic CO. Do not run the generator in dead-air
space. Make sure to provide enough air.
Warning
The gasoline is very easy to burn or explode under specific conditions.
Turn off the engine before filling.
When filling the engine, keep away from cigarettes or spark. Please fill in a
draught.
Clean the overflowed gasoline immediately.
Warning
Each time before you start the engine, you must do check it first,
avoiding accidents or damage of the equipment.
The generator must be run at a place at least one meter away from the
buildings or other equipments.
The generator must be run on a horizontal surface. If it leans, the
gasoline would spill out.
You must master the knowledge of how to turn off the generator quickly,
and know all the operations of controlling the components. Do never operate the
engine without correct instructions.
Children and pets must be kept away from the operating area.
When the engine is running, everyone must keep away from the
circumvolving parts.
The generator is a latent danger if it is incorrectly operated, so do not
operate it by hand.
Do not operate the generator in the rain or in the snow, preventing
wetting it.

G1000i Inverter Generator
5
2. abel position of safety matters
These labels warn you of those latent dangers that will possibly cause serious
accidents involving casualties. Please read carefully the words on the labels, the
safety warnings and the notes recounted in the guide. If the labels have fallen off
or are illegible, please contact the G1000i agent and change them.

G1000i Inverter Generator
6
3. Components identifier

G1000i Inverter Generator
7
Controlling panel:
Attention:
Tip: We have a smart display: when the machine is running it the state of voltage,
frequency, and power used by the machine. It can be useful to avoid overloading
when using the machine.
Intelligent gasoline-saving valve:
When the engine is disconnected from the electrical equipment, the velocity of
the generator will slow down automatically. When the equipment is connected,
the electric charge will make the generator return to a proper rotate speed. This
installation is used to reduce the gasoline consumption during the running
process.

G1000i Inverter Generator
8
Warning
When the electrical equipment needs disconnecting from the electric power,
the intelligent gasoline-saving system can not run effectively.
When the generator is connected with a high electric charge, turn off the
intelligent gasoline-saving valve to minimize the change of middle pressure.
When using the DC output, please turn off the intelligent gasoline-saving
valve.
Close:
It means the intelligent gasoline-saving system is closed, and the rotate speed of
the generator is kept on a level higher than the standard rotate speed.

G1000i Inverter Generator
9
4. Check before operation
Warning
Check the generator, keep it on a horizontal surface without fail, and ensure
that the engine is turned off.
1. Check the oil level
Warning
Using oil without cleanser or 2-strokes engine’s oil may shorten the
generator’s service life.
Please use oil containing high quantity of cleanser or use high quality 4-strokes
engine’s oil. The quality level must answer for or exceed the SG/SF level which
is required by the American manufacturer and lay down by American Petroleum
Institute.
Please choose the engine oil with proper ropy degree based on the average
temperature of the area you live in.
Dismantle the machine oil ruler, rub up it with clean duster cloth, and stick it into
the oil-filling mouth to check the oil level. Pay attention not to drop the ruler into
it.
If the machine oil level is below the bottom of the machine oil ruler, fill the
recommended machine oil into the gasoline-filling mouth.
Warning
If the engine runs when oil is in shortage, it can be seriously damaged.
Note:
The oil alarming system will turn off the engine before the oil level descends to

G1000i Inverter Generator
10
the security line. But to avoid the inconvenience caused by unexpected machine
halt, we advise you to check the oil level regularly.
2. Check the gasoline level:
Please use gasoline for cars. (It’s better to use no lead gasoline or having low
content of lead, in order to reduce the accumulation of charcoal in the burning
room.)
If the gasoline level is too low, please add gasoline into the gasoline tank until it
reaches the required level.
Do never use the mixture of machine oil and gasoline or uncleaned gasoline.
Prevent filth, dust, or water entering the gasoline tank.
Screw down the gasoline-filling lid after filling the gasoline.
Warning
The gasoline is very easy to burn or explode under specific conditions.
Please fill the generator in a draught, and turn off the engine before filing. It
is strictly forbidden to smoke close to the gasoline-filling and gasoline-storing
parts of the generator.
The gasoline must not be spilled out of the gasoline tank (the gasoline-filling
mouth should not have any gasoline). Screw down the gasoline-filling lid after
filling the gasoline.
Be careful not to let the gasoline spill out when filling the generator. The
gasoline overflowed or mist may take fire. Once there is some oil spilling out,
make sure that the oil-spilled area is dried before starting the engine.
Avoid exposing your skin to the gasoline in a long time or repeatedly. Do not
let children have contact with it.