LGX®-Compatible (LSX) Preterminated
Termination/Splice Panel With Pigtails
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1 DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4 UNPACKING THE PRODUCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1 Installing the Combination Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2 Grounding an Armored Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.3 Breaking Out a Cable for Splicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.4 Installing a Cable Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.5 Feeder Cable Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.5.1 Cable Routing for 7-Inch and 9-Inch High Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.5.2 Cable Routing for 1.75 Inch High Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.5.3 Cable Routing for 3.5 Inch High Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6 PATCH CORD ROUTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.1 Patch Cord Routing Within the LSX Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.2 Routing Patch Cords on the LGX Bay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
(Continued)
Content Page
17521-A
ADCP-93-095 Rev B April 2018

ADCP-93-095 • Rev B • April 2018
Page 2
© 2018, CommScope, Inc.
6.2.1 Cross-Connecting Within a Stand-Alone Bay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.2.2 Cross-Connecting Between Adjacent Bays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.2.3 Cross-Connecting to Non-Adjacent Bays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.2.4 Routing Patch Cords Starting in the Lower Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.2.5 Routing Patch Cords Starting in the Upper Raceway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.3 Mounting 144-Position Modules Adjacent to 72 or 96 Position Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
7 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
7.1 Removing a Cover for Easier Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
7.2 Patching and Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
8 CUSTOMER INFORMATION AND ASSISTANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
INTRODUCTION
This user manual describes the CommScope LGX Compatible (LSX) Preterminated
Termination/Splice Panel With Pigtails, and provides instructions for installation and operation.
Revision History
quad cables and patch cord routing
Trademark Information
LGX and CommScope are trademarks.
Related Publications
(http://www.commscope.com/SupportCenter)
LGX-Compatible (LSX) 288-Position Termination/Splice Panel User Manual 93-103
LGX-Compatible (LSX) Connector Module User Manual 93-089
Armored Plenum Compact Building Cable Ground Clamp Kit
(GND-STPKIT) Installation Instructions 90-382
1 DESCRIPTION
The LSX Preterminated Termination/Splice Panel With Pigtails is an LGX style, rack-mounted
panel that provides a splicing transition between one or more fiber optic cables and a
termination bulkhead for fiber optic patch cords.
Content (continued) Page
ISSUE DATE REASON FOR CHANGE
Issue 1 05/2002 Original.
Rev B April 2018 Changed to CommScoope format.
Title ADCP Number

ADCP-93-095 • Rev B • April 2018
Page 3
© 2018, CommScope, Inc.
In a typical application, the LSX panel serves as a splicing and distribution point to transition
from Outside Plant (OSP) or Intra Facility Cable (IFC) to inbuilding circuits connected to with
patch cords. The panel may be used in either an interconnect or cross-connect configuration,
and in either singlemode or multimode applications.
Figure 1 summarizes the functional components of the LSX termination panel. As shown, an
OSP or IFC cable is routed through the panel to the splice area access door, which serves as a
splice deck. On the splice area rear access door, located on the rear of the panel, the component
fibers are spliced to the internal pigtails. The factory-terminated internal pigtails transition to
the bulkhead, located on the front of the panel. Patch cords installed from the front side of the
panel provide the connection to fiber optic terminal equipment.
Figure 1. Functional Components of LSX Preterminated
Termination/Splice Panel (Cut-Away Top View)
INTERNAL
PIGTAILS
SPLICE AREA
ACCESS DOOR
OSP OR IFC
CABLE
17530-A
MASS FUSION
SPLICE CHIP
BULKHEAD FOR
PATCH CORD
TERMINATION

ADCP-93-095 • Rev B • April 2018
Page 4
© 2018, CommScope, Inc.
The LSX panel is shipped with pre-terminated, factory-installed ribbon or stranded pigtails. The
panel is available in five chassis heights with different numbers of termination positions, as
follows: 1.75-inch high with 12 or 24 termination positions; 3.5-inch high with 48 termination
positions; 7-inch high with 72 or 96 positions; 9-inch high with 144 positions; and 11-inch high
with 288 positions (documented in a separate manual). Figure 2 shows the main external
features of the 7-inch high panel. The 1.75-inch, 3.5-inch, and 9-inch high panels have
analogous features.
Figure 2. Main External Features of 7-Inch High LSX Termination/Splice Panel (Front View)
The features shown are as follows (see Figure 2):
•LGX-Compatible Chassis—is of solid metal construction and painted white. Nine 7-inch
chassis or seven 9-inch chassis may be installed on an LGX frame.
•Bulkhead—holds the pass-through adapters that provide the physical interface between
the connector ends of internal pigtails and patch cords installed on the bulkhead.
•Adapter Pack—6-, 8-, 12- or 24-pack depending on model; mounts in the bulkhead
providing one column of adapters/connectors for terminating patch cords. Connector types
available include singlemode USC, ASC, and UFC, and multimode SC.
•Patch Cord Guides—provide cable management in routing patch cords.
•Removable Front Cover—provides unimpeded access for installation of patch cords.
•Patch Cord Designation Card—is used to record patch cord usage.
•Removable Radius Limiter—provides bend radius protection for the fibers.
17523-A
CONNECTOR
PACK
BULKHEAD
LGX
COMPATIBLE
CHASSIS
PATCH CORD
GUIDE REMOVABLE
FRONT COVER PATCH CORD
DESIGNATION
CARD
MOUNTING
BRACKET
SPLICE AREA
ACCESS DOOR
REMOVABLE
RADIUS
LIMITERS

ADCP-93-095 • Rev B • April 2018
Page 5
© 2018, CommScope, Inc.
•Mounting Brackets—may be oriented for either 19-inch or 23-inch rack mount.
Every LSX Termination/Splice Panel has a rear splice area such as shown in Figure 3 for the 7-
inch panel. The other height panels have analogous features.
Figure 3. LSX Termination/Splice Panel (Rear View)
The main features in the rear splice area are as follows:
•OSP or IFC Cable Clamp—secures cable to chassis.
•Kurley Locks—route and secure cable fibers and internal pigtails.
•Splice Storage Spools—provides service loop storage for cable fibers and pigtails.
•Mass Fusion Splice Chip—splices 24 fiber/pigtail interfaces.
•Splice Area Access Door—folds down providing a horizontal splice deck.
•Cable Ring—routes and secures cable on entry into splice area.
•Ribbon Fanout Bracket—holds one stack of four ribbon fanout chips (if ribbon rather
than stranded pigtails are present).
•Wing Nut—secures the cover (next item) to hold it in place.
•Cover—protects splices once completed.
Each panel is shipped with a cable clamp.
17531-A
OSP OR IFC
CABLE CLAMP
KURLEY LOCK
(TYPICAL)
MASS FUSION
SPLICE CHIP
WING
NUT
COVER
SPLICE AREA
ACCESS DOOR
CABLE RING
(TYPICAL)
RIBBON
FANOUT
BRACKET
SPLICE
STORAGE
SPOOL

ADCP-93-095 • Rev B • April 2018
Page 6
© 2018, CommScope, Inc.
2 DIMENSIONS
Figure 4 shows dimensions for the most common chassis heights, 7-inch and 9-inch. Figure 5
shows dimensions for 1.75-inch high panel. Figure 6 shows the 3.75-inch high panel.
Figure 4. Dimensions for 7-Inch and 9-Inch High Panel
14.84 IN.
(37.7 CM)
16.84 IN.
(42.8 CM)
18.15 (46.1 CM)
19-IN. RACK MOUNT (48.3 CM)
22.15 (56.3 CM)
23-IN. RACK MOUNT (58.4 CM)
7.53 IN.
(19.1 CM)
15.0 IN.
(38.1 CM)
5.0 IN.
(12.7 CM)
7.0 IN. (17.8 CM) HEIGHT ON 72 OR 96 POSITION MODULES OR
9.0 (22.9 CM) HEIGHT ON 144 POSITION MODULES.
1.0 IN.
(2.5 CM)
1.0 IN.
(2.5 CM)
2.0 IN.
(5.1 CM)
17524-A
1
1
TOP VIEW
FRONT VIEW

ADCP-93-095 • Rev B • April 2018
Page 7
© 2018, CommScope, Inc.
Figure 5. Dimensions for 1.75-inch High Panel
Figure 6. Dimensions for 3.50-inch High Panel
FRONT VIEW
16.84 IN.
(42.8 CM)
19.33 (49.1 CM)
19-IN. RACK MOUNT (48.26 CM)
TOP VIEW
23499-A
5.0 IN.
(12.7 CM)
12.0 IN.
(30.5 CM)
1.73 IN.
(4.4 CM)
FRONT VIEW
16.84 IN.
(42.8 CM)
19.33 (49.1 CM)
19-IN. RACK MOUNT (48.26 CM)
TOP VIEW
23500-A
5.0 IN.
(12.7 CM)
12.0 IN.
(30.5 CM)
5.23 IN.
(13.3 CM)

ADCP-93-095 • Rev B • April 2018
Page 8
© 2018, CommScope, Inc.
3 SPECIFICATIONS
Table 1 lists specifications for the LSX panel.
Table 1. LSX Combination Module Specifications
PARAMETER SPECIFICATION REMARKS
General
Color Putty white
Rack mounting 19- or 23-inch EIA or WECO hole spacing
Connector Types Singlemode ASC, USC, UFC
Multimode USC
7-Inch High Panel
Number of Terminations 72 or 96
Dimensions (HxWxD) 7.0 x 17.0 x 12.0 inches
(17.8 x 435 x 281.7 mm)
See Figure 4
Weight 25 lbs. (11.34 kg)
9-Inch High Panel
Number of Terminations 144
Dimensions (HxWxD) 9.0 x 17.0 x 12.0 inches
(22.9 x 435 x 281.7 mm)
See Figure 4
Weight 25 lbs. (11.34 kg)
1.75-Inch High Panel
Number of Terminations 12 or 24
Dimensions (HxWxD) 1.73 x 17.0 x 12.0 inches
(4.4 x 43.1 x 30.5 cm)
See Figure 5
Weight 10 lbs. (4.53 kg)
3.5-Inch High Panel
Number of Terminations 48
Dimensions (HxWxD) 5.22 x 17.0 x 12.0 inches
(13.3 x 43.1 x 30.5 cm)
See Figure 6
Weight 15 lbs. (6.8 kg)

ADCP-93-095 • Rev B • April 2018
Page 9
© 2018, CommScope, Inc.
4 UNPACKING THE PRODUCT
Unpack and inspect the LSX panel as follows:
1. Inspect the exterior of the shipping container for evidence of rough handling that may have
damaged the contents of the container.
2. Unpack the panel and associated components and check for possible damage.
3. If damage is detected or if parts are missing, file a claim with the commercial carrier and
then notify CommScope Customer Service. Save the damaged carton for inspection by the
carrier.
4. Save the shipping container for use in case the equipment requires shipment at a future
date.
5 INSTALLATION
The main steps in installing an LSX panel are:
• Mounting the panel on the frame,
• Breaking out the cable to be spliced within the panel,
• Installing the cable on the outside of the panel, and
• Routing the cable within the panel from the cable clamp to the splice deck.
For instructions, refer to the following subsections.
5.1 Installing the Combination Module
Install the panel from the front side of the rack, using the following procedure. Refer to
Figure 7.
Note: For information on how to contact CommScope Customer Service, if needed, refer
to Section 8 in this manual.
Note: Because of its extra depth due to its rear splice area, the LSX panel should be
installed on an LGX fiber distribution frame with a depth of at least 15 inches (38.1 cm).

ADCP-93-095 • Rev B • April 2018
Page 10
© 2018, CommScope, Inc.
Figure 7. Installing the Connector Module (23-Inch Rack Shown)
1. Determine the mounting location and rack width, and reposition the mounting brackets if
required:
a. If installing the panel on a 19-inch rack, remove the two mounting brackets and re-
install them using the 19-inch orientation (refer to Figure 4).
b. If installing the panel on a 23-inch rack, install the chassis with the mounting brackets
positioned as shipped.
2. Secure the mounting brackets to the rack front flange using six #12-24 mounting screws.
5.2 Grounding an Armored Cable
When installing an armored cable, a procedure is required, before breaking out the cable, to
sever and ground the armor. A CommScope kit is available for grounding the armor (catalog #
GND-STPKIT). For details, refer to the instructions shipped with the kit (ADCP-90-382).
Note: If jumper retainers are present on the rack, remove the jumper retainers and reinstall
them with the chassis as shown in Figure 7. The jumper retainers may be either LGX or
the CommScope equivalent product.
LGX JUMPER
RETAINER
26637-A
MOUNTING
BRACKET
RACK FRONT
FLANGE
12-24X SCREW (6)
LGX JUMPER
RETAINER
Autres manuels pour LSX
1
Table des matières
Autres manuels CommScope Unité de distribution d'énergie