Colby Instruments PDL-100A Manuel du propriétaire

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Colby Instruments PDL-100A-1.25NS at our website: Click HERE

___________________________________
PDL-100A Programmable Delay Line
Operating and Programming Manual
1715 114th Avenue SE
Woodridge Building –Suite 112
Bellevue, WA 98004
(425) 452-8889 VOICE || (425) 452-8802 FAX
www.colbyinstruments.com
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

© 2010 Colby Instruments. PDL-100A Operating and Programming Manual.
Hardware Version 1.0 REV 1.0. Firmware Version 1.70.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

© 2010 Colby Instruments. PDL-100A Operating and Programming Manual.
Hardware Version 1.0 REV 1.0. Firmware Version 1.70.
Certification and Warranty
CERTIFICATION
Colby Instruments certifies that the PDL-100A Series of Programmable Delay Line
Instruments meets all published specifications at the time the instruments are shipped
from the manufacturer. SPECIFICATIONS ARE SUBJECT TO CHANGE
WITHOUT NOTIFICATION.
WARRANTY
The product is warranted against defects in material and workmanship for a period of one
year from date of shipment. During the warranty period, Colby Instruments will at its
option, either repair or replace the product or item which proves to be defective.
Replacement products may be either new or like-new.
EXCESSIVE WEAR OF CONNECTORS, THE TROMBONE UNIT, THE
COAXIAL RELAYS, AND OTHER RELAYS CARRYING THE SIGNAL, ARE
NOT COVERED BY THE WARRANTY. THE FOREGOING WARRANTY
SHALL NOT APPLY TO DEFECTS RESULTING FROM IMPROPER CARE
OR USE OF THE INSTRUMENT BY THE BUYER. THIS SHALL APPLY TO
ALL COMPONENTS DELIVERED TO THE BUYER.
For warranty service or repair, this product must be returned to Colby Instruments. The
Buyer shall prepay all shipping charges for the shipment of item to Colby Instruments.
Colby Instruments shall pay the shipping charges to return the product to the Buyer.
However, the Buyer shall be responsible for ALL shipping charges, duties and taxes for
product returned to Colby Instruments from outside the United States of America.
BUYER MUST OBTAIN A RETURN MATERIAL AUTHORIZATION NUMBER
(RMA #) FROM COLBY INSTRUMENTS PRIOR TO THE SHIPMENT OF ANY
ITEM TO COLBY INSTRUMENTS. SHIP TO:
Colby Instruments
Attn: RMA # ________
1715 114th Avenue SE
Woodridge Building –Suite 112
Bellevue, Washington 98004
USA
No other warranty is expressed or implied. Colby Instruments specifically disclaims the
implied warranties or merchantability and fitness for a particular purpose. The remedies
provided herein are the Buyer's sole and exclusive remedies. Colby Instruments shall not
be liable for any direct or special, incidental or consequential damages, whether based on
contract, tort, or any other legal theory.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

© 2010 Colby Instruments. PDL-100A Operating and Programming Manual.
Hardware Version 1.0 REV 1.0. Firmware Version 1.70.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

© 2010 Colby Instruments.PDL-100A Operating and Programming Manual Page i
Table of Contents
Chapter 1.0
Description of the PDL-100A Programmable Delay Line Series ....... 1
1.0.1 Introduction...............................................................................................1
1.0.2 Delay Line Structure and Design ..............................................................2
Chapter 2.0
Getting Started .............................................................................. 3
2.0.1 Using the PDL-100A for the First Time .....................................................3
2.0.2 Self-Test After Power Up..........................................................................4
2.0.3 Self-Test without MT-100A Microterminal connected ...............................4
2.0.4 Self-Test with MT-100A Microterminal connected ....................................5
Chapter 3.0
Using the Front Panel Connections ................................................ 7
3.0.1 Overview of the Front Panel Connections ................................................7
3.0.2 About Series Connected or Parallel Connected Mode .............................8
3.0.3 About Delay Extensions ...........................................................................8
Chapter 4.0
Setting Delay Values......................................................................11
4.1.0 Working with the MT-100A Microterminal...............................................11
4.1.1 The MT-100A Microterminal at a glance.................................................12
4.1.2 Working with the MT-100A Microterminal Keypad..................................13
4.2.0 Setting Delay with the MT-100A Microterminal.......................................15
4.3.0 The MT-100A Menu Keys –SETUP........................................................16
4.3.1 The MT-100A Menu Keys –SETUP cont. ...............................................17
4.3.2 About the SETUP Menu options.............................................................17
4.3.3 SETUP Menu –GPIB Address ................................................................17
4.3.4 SETUP Menu –Network Addresses........................................................18
4.3.5 SETUP Menu –RS-232 Terminal Mode or MT-100A Mode ....................18
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

© 2010 Colby Instruments.PDL-100A Operating and Programming Manual Page ii
4.4.0 The MT-100A Menu Keys –DIAG ...........................................................19
4.4.1 About the DIAG Menu options ................................................................19
4.4.1.1 DIAG MENU –Relays.......................................................................20
4.4.1.2 DIAG MENU –Device Calibration.....................................................20
4.4.1.3 DIAG MENU –Resetting the PDL-100A ...........................................20
4.5.0 Working Remotely Through the GPIB Interface......................................21
4.5.1 Connecting remotely over GPIB (IEEE488.2).........................................21
4.5.2 Setting the GPIB (IEEE488.2) Address ..................................................21
4.5.3 Setting the delay using GPIB (IEEE488.2) Commands ..........................23
4.5.4 Using National Instruments Measurement and Automation Explorer .....23
4.6.0 Communicating with the PDL-100A over Ethernet TCP/IP.....................25
4.6.1 Default Network Addresses.................................................................25
4.6.1.1 Programming over the Ehternet TCP/IP...........................................25
4.6.2 Using HyperTerminal and Ethernet (TCP/IP) ......................................26
4.7.0 Setting the delay over RS-232 Serial Port and PC .................................28
4.7.1 Attaching the MT-100A Microterminal to the RS-232 port...................28
4.7.2 Attaching the PC to the RS-232 port...................................................28
4.7.2.1 Programming over the RS-232 connection ......................................29
4.7.2.2 Error Checking.................................................................................29
4.7.3 Using HyperTerminal and RS-232 connection....................................30
Chapter 5.0
Common Commands ....................................................................33
5.1.0 Summary of Common Commands .........................................33
*CAL Calibration COMMAND ..............................................................34
*CAL? Calibration Query QUERY..........................................................35
*IDN? Identification QUERY .................................................................35
*RST Reset COMMAND ......................................................................36
*OPC Operation Complete COMMAND ...............................................37
*OPC? Operation Complete COMMAND ...............................................37
*TST? Test Operation Query QUERY ...................................................38
*ESE Event Status Enable COMMAND ...............................................39
*ESE? Event Status Enable Mask QUERY............................................40
*ESR? Operation Complete QUERY......................................................40
*CLS Clear Status COMMAND............................................................41
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

© 2010 Colby Instruments.PDL-100A Operating and Programming Manual Page iii
Chapter 6.0
System Commands........................................................................43
6.1.0 Summary of System Commands............................................43
DEC DECREMENT COMMAND ........................................................46
DEL Delay COMMAND ......................................................................45
DEL? Delay QUERY ............................................................................46
DTIME? Delta Time QUERY ....................................................................46
ERR? ERROR QUERY.........................................................................48
EXEC COMMAND ................................................................................50
INC INCREMENT COMMAND ..........................................................49
MODE MODE COMMAND ....................................................................51
MODE? MODE QUERY...........................................................................52
NET NETWORK COMMAND .............................................................51
NET? NETWORK ADDRESS QUERY .................................................52
NETM? NETWORK MAC_ID ADDRESS QUERY...................................53
RATE RATE COMMAND......................................................................56
RATE? RATE? QUERY ..........................................................................56
REL RELAY COMMAND....................................................................55
REL? RELAY QUERY..........................................................................56
RELC RELC COMMAND......................................................................51
STEP STEP COMMAND ......................................................................51
STEP? STEP QUERY ............................................................................58
STORE STORE COMMAND ..................................................................60
STORE? STORE? QUERY........................................................................61
STOREQ?STOREQ? QUERY ....................................................................62
XDD XDD COMMAND .......................................................................63
XDD? XDD? QUERY ...........................................................................64
Chapter 7.0
Instrument Backpanel ...................................................................65
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

© 2010 Colby Instruments.PDL-100A Operating and Programming Manual Page iv
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Chapter 1 Description of the PDL-100A Programmable Delay Line Series
© 2010 Colby Instruments. PDL-100A Operating and Programming Manual Page 1
Description of the PDL-100A
Programmable Delay Line Series_______
1.0.1 Introduction
The PDL-100A Programmable Delay Line (PDL) Instrument Series offers a
range of variable and programmable delay beginning from 0 delay (DC) to a
customer specified maximum delay limit of 100 nanoseconds (depending on
specific model) in a single system unit. With resolution precision to 0.50
picoseconds per step and wideband signal frequency input from DC to 18 GHz,
the PDL-100A is the finest programmable delay line instrument available in the
marketplace.
The base model PDL-100A-625PS offers electrical delay through a patented
electromechanical trombone unit with movement controlled by a high precision
stepper motor. Resolution is to 0.50 picoseconds and repeatability to 0.10
picosecond accuracy. Total delay range of the trombone only model PDL-100A-
000 is from DC to 625 picoseconds.
For models PDL-100A-1.25NS and above, delay range extensions consisting of
microwave relays and low-loss semi-rigid coaxial cable are added to extend the
delay range limit up to a customer specified maximum of 100 nanoseconds.
The Model Number of each specific instrument determines the maximum delay
range available. The last few characters of each model number indicate the total
delay range.
Model Number
Delay Range
PDL-100A-625PS
DC to 0.625 ns
PDL-100A-1.25NS
DC to 1.250 ns
PDL-100A-10.0NS
DC to 10.00 ns
PDL-100A-20.0NS
DC to 20.00 ns
PDL-100A-100.0NS
DC to 100.0 ns
All signal input and output connections are easily accessible at the front panel and
are terminated with Female SMA (50 ohm impedance) connectors.
PDL-100A Series Instruments are programmable and can be locally controlled
through a MT-100A Microterminal (optional accessory available separately) or
remotely through GPIB (IEEE 488.2), TCP/IP Ethernet, or RS-232 Serial Port
interfaces.
1.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Ce manuel convient aux modèles suivants
6
Table des matières
Autres manuels Colby Instruments Générateur d'impulsions
Manuels Générateur d'impulsions populaires d'autres marques

Hagerman Technology
Hagerman Technology FryBaby Manuel utilisateur

BNC
BNC MOD745T Manuel utilisateur

AVTECH ELECTROSYSTEMS LTD.
AVTECH ELECTROSYSTEMS LTD. AVG-4A-B Manuel utilisateur

Avtech
Avtech AVR-G1-B Manuel utilisateur

Avtech
Avtech AVOZ-D2-B Manuel utilisateur

Tektronix
Tektronix 114 Manuel utilisateur












