COLBOR CL220 Manuel utilisateur

Thank you for choosing COLBOR product. Please read this manual
carefully before use and follow all instructions mentioned herein.
Video Light User Manual
CL220

Caring For Your COLBOR Product
Power Connection
You must use the power adapter that comes with the product rather than
other adapters to avoid damaging the lamp. The positive and negative
connections of the power adapter interface( DC OUT) and the lamp power
interface (DCIN) are shown below:
+ -- +
N N
Keep corrosive chemicals, liquids and heat source away from the product to
prevent mechanics damage.
The product is not waterproof.
Do not leave the product unattended while in use. Keep out of reach of
children.
Do not handle with wet hands. Do not touch the hot COB surface.
Please do not block the ventilation and do not look at the light directly when
it is on.
Do not attempt to disassemble or modify the product. Doing so voids
warranty.
Please have the product checked or repaired by authorized technicians if
any malfunctions happened.
Disconnect from the power supply when it is not in use.
Do not cover, inverted COB and radiator for high temperature, do not cover,
inverted, do not touch the lamp holder and radiator vent with your hands
when the product in use.
Do not use any power adapter of other products to avoid the lamp
malfunction.
Malfunction may be caused by dropping, impact of external force.
Failure to follow all the instructions may result in mechanics damage.
Our company reserves the right of nal interpretation of the product.
Product design and specications are subject to change without prior
notice.

Product Instructions
① LED Display Screen
② EFF Mode Button
③ EFF Rate Option Button
④ Color Temperature Option Button
⑤ Setting Button
⑥ Color Temperature Control Knob
⑦ Brightness Control Knob
⑧ DC 48V Power Port
⑨ Power Button
⑩ Bowens Mount
⑪ COB Lamp Beads
⑫ Lamp Angle Adjustment Locking Grip
⑬ Bracket
⑭ Air Outlet
⑮ NATO Slideway
⑯ Air Inlet
⑰ Lamp Grip
⑱ Soft Light Cover Hole
⑲ Soft Light Cover Hole Screws
⑳ Bracket Screw
Light Installation
Hold the COB cover with the Bowens Mount
tenon and rotate it as the direction of the arrow.
Note: Be sure to remove COB protective cover
and COB protective lm before use.
Installation of reector: Align the reector with the groove around the lamp
head and clip it in, turn the reector as the direction of the arrow, and the
reector installation will be completed after the top rod rebounds.
Removal of reector: Under the instructions of “Lamp Cap Protection Cover
Removal".
1. Removal of lamp cap protection cover
2. Installation and removal of reector

Rotate the lamp holder screw until the inner wall not shielded and put the
product on the top of the lamp holder to tighten the bracket screw for xation.
Adjust the lamp body irradiation Angle and tighten the lamp holder Angle grip
xed.
3. Installation and xation of light
Screw out, the inner
wall of the bracket
without any shelter
Halfway the screw out The screw is not out
at all
Screw out, the inner wall of the
soft light cover without shelter
The screw is not out at all
Insert the handle of the soft light umbrella into the umbrella hole. After
adjustment, lock the cover hole screw.
4. Install the soft light cover
(1) Mount the power adapter
Do not suspend the power adapter in the air. Use
wire rings to hang it on the lamp stand.
5. Power Connection
(3) Power cord storage
Please turn off the lamp before unplugging
the power cord. When unplug the power
cable, hold down the safety lock on the
connector before removing it. If unlocked,
do not forcibly remove the power supply.
(2) Power with power adapter
Connect the power adapter, align the pin with the
DC power interface of the lamp body, and then
power through the cable
after stable.

Note:
* For one 14.8V battery powering, the maximum brightness is 50% of full
power.
* When battery runs low, the brightness will adjust accordingly for protecting
the power cord from overheating due to excessive current.
* Dual V-port battery mobile power supply solution is recommended.
(4) Power with V-port battery
Mount the V-port battery to the lamp by complimentary the NATO expansion
bar with VM3 (optional), and then connect the D-tap to XLR power cable to
start the lamp.

None grouping status. The product defaults to the factory
status, and will not be aected by other groups.
If the icon ashes, it means that the internal temperature of the
product is too high, and cooling measures need to be taken. If
the icon disappears, it means that the operation is normal.
③ Group Status Icon
④ Product Overheated Alarm Icon
A stands for Group A. There are fteen groups (A~O). T
stands for Tx.
A stands for Group A. There are fteen groups (A~O). R
stands for Rx.
A stands for Group A. There are fteen groups (A~O). TR
stands for TxRx.
Operation Instructions
1. Please remove the COB protective cover before using the light.
2. Turn on the lamp: After conrming that the power connection is normal,
press the switch to "-", and the screen will display the brand and product
module, and then enter the operation interface. (Default mode: CCT)
3. Turn o the lamp: press the switch to "o" to turn o the power switch.
1. Status Icon Description
After selecting wireless connection in Settings menu, the
icon will be displayed dynamically.
The icon is always on to indicate successful pairing with
mobile APP.
The icon disappears to indicate mobile APP pairing failure, or
the product is unpaired.
Smart Mode. The product will adjust the fan speed according
to the internal detected temperature to ensure that it is in
optimal working condition.
Quiet Mode. The fan keeps running at low speed for minimum
noise, and overheating protection will be activated if the
product temperature is higher than the alarm value.
Performance Mode. Fan runs at the highest speed to ensure
heat dissipation.
① APP Connection Status Icon
② Fan Status Icon

2. CCT Mode (Short press CCT Mode Button to enter)
Turn the knob clockwise or anti-clockwise to adjust color
temperature (CCT) from 2700K~6500K
Press down the knob to quickly switch the preset color temperature
to 2700K, 3200K, 4000K, 5600K, and 6500K
Turn the knob clockwise or anti-clockwise to adjust brightness (DIM)
from 0%~100%
Press down the knob to quickly switch the preset brightness to 0%,
25%, 50%, 75%, and 100%
Color Temperature Control Knob
Brightness Control Knob
Rolling the knob will enlarge the current setting parameter value, and it will
automatically return to the main screen after 1.5 seconds of no operation
Brightness
Color Temperature
CCT Mode Button

Turn the knob clockwise or anti-clockwise to adjust color
temperature (CCT) from 2700K~6500K
Press down the knob to quickly switch the preset color temperature
to 2700K, 3200K, 4000K, 5600K, and 6500K
Turn the knob clockwise or anti-clockwise to adjust brightness (DIM)
from 0%~100%
Press down the knob to quickly switch the preset brightness to 0%,
25%, 50%, 75%, and 100%
Press to switch light eect: Fire → CCT Chase → Pulsing → TV →
Explosion → Faulty Bulb → Welding → Strobe → Lightning → S.O.S
Color Temperature Control Knob
Brightness Control Knob
Light Eect Mode (EFF) Button
EFF Mode Button
Rate Option Button
Special Eect Brightness
Rate
Color Temperature
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: LOCK
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: LOCK
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: LOCK
DIM: 0%-100%
CCT: 2700K-6500K
Fire
CCT Chase
Pulsing
TV
Explosion
Faulty Bulb
Welding
Strobe
Lightning
S.O.S
EFF
3. EFF Mode (Short press EFF Mode Button to enter)

4. Setting
1. Short press the setting botton to enter settings menu.
2. Turn the brightness control knob clockwise or anti-clockwise to choose
setting.
3. Press the setting botton to adjust corresponding setting (Short press the
setting botton to adjust the wireless connection mode).
Fan Mode
Wireless
Connection
Communication
Settings Options
SMART/ QUIET/ PERFORMANEC
SMART: The product will detect
the current internal temperature to
adjust the fan speed by itself.
QUIET: The fan will run at low
speed. If the product temperature
reaches the alarm value, it will
start the power-o protection
mechanism.
PERFORMANEC: Fan runs at
the highest speed to ensure heat
dissipation.
APP/Remote Control
Long press the setting button for
pairing (One mode for each time)
TX/ RX/ TXRX (TX by default)
Group NULL/ A~O (NULL by default)
Response
Initial brightness
setting
Language
SHARP/ SMOOTH
(SMOOTH by default)
Default、0%、25%、75%、100%
EN/ CN
Curve LINEAR, L.CURVE, E.CURVE,
S.CURVE.
Short press the setting botton to
enter the production information
interface. Press the setting botton
again to go back to settings menu.
① Hardware Version
② Firmware Version
③ Protocol Version
④ MAC Address
Product INFO.

5. APP Connection & Light Control
Scan the QR code,or search “COLBOR STUDIO" in app store to download
the app for light control.
CL220 Pairing:
1. Press the
setting button
and enter the pairing mode. Short press the
setting
button
to choose “APP”, then long press the
setting button
for 3 seconds for
pairing.
Table des matières
Autres manuels COLBOR Équipement d'éclairage

COLBOR
COLBOR BP90 Manuel utilisateur

COLBOR
COLBOR PL8-R Manuel utilisateur

COLBOR
COLBOR BP45 Manuel utilisateur

COLBOR
COLBOR CL220R Manuel utilisateur

COLBOR
COLBOR PL5 Manuel utilisateur

COLBOR
COLBOR CL100 Manuel utilisateur

COLBOR
COLBOR CL330M Manuel utilisateur

COLBOR
COLBOR CL60M Manuel utilisateur

COLBOR
COLBOR CL220M Manuel utilisateur

COLBOR
COLBOR CL330 Manuel utilisateur
Manuels Équipement d'éclairage populaires d'autres marques

Qazqa
Qazqa Suplux SL 3 Black 103062 Manuel utilisateur

Commercial Electric
Commercial Electric 54568141 Manuel utilisateur

CREE LIGHTING
CREE LIGHTING 304 Series Manuel utilisateur

Goobay
Goobay 49867 Manuel utilisateur

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manuel utilisateur

Alkalite
Alkalite Krypton KT-81 Manuel utilisateur