Code Blue Centry Series Manuel de service

800.205.7186 •www.codeblue.com
Centry® Series
Administrator Guide
Installation | Configuration | Operation | Troubleshooting

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-162-Epage 2 of 56
Centry®
Administrator Guide
WARNING
ONLY QUALIFIED PERSONNEL SHOULD INSTALL THESE UNITS. THE INSTALLATION
SHOULD CONFORM TO ALL LOCAL CODES. IN SOME COUNTRIES, A CERTIFIED ELECTRI-
CIAN MAY BE REQUIRED.
NOTICE TO USERS
Copyright © Code Blue Corporation. All rights reserved. This guide or software described herein, in
whole or part, shall not be reproduced, translated or reduced to any machine-readable form without
prior written approval from Code Blue Corporation.
CODE BLUE CORPORATION PROVIDES NO WARRANTY WITH REGARD TO THIS GUIDE, THE
SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DIS-
CLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICU-
LAR PURPOSE WITH REGARD TO THIS GUIDE, THE SOFTWARE OR SUCH OTHER INFORMA-
TION. IN NO EVENT SHALL CODE BLUE CORPORATION BE LIABLE FOR ANY INCIDENTAL,
CONSEQUENTIAL, OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR
OTHERWISE, ARISING OUT OF OR IN CONNECTIONS WITH THIS GUIDE, THE SOFTWARE
OR OTHER INFORMATION CONTAINED HEREIN OR THE USE THEREOF.
Code Blue Corporation reserves the right to make any modications to this guide or the information
contained herein at any time without notice. The software described herein may also be governed
by the terms of a separate user license agreement.
Code Blue®is a registered trademark of Code Blue Corporation. The names of actual companies
and products mentioned herein may be the trademarks of their respective owners.

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-162-Epage 3 of 56
Centry®
Administrator Guide
Table of Contents
Section Page
2 Introduction................................................................................. 4
3 Getting Started............................................................................ 5
4 Installation Instructions............................................................. 8
5 Wiring Diagram........................................................................... 12
6 Flush Mount Mounting Schematics.......................................... 13
7 Surface Mount Mounting Schematics....................................... 14
8 Curb Mount Installation Instructions........................................ 15
9 Setting Up your Centry®Help Point®..........................................18
10 In-Call Commands...................................................................... 34
11 Compatibility............................................................................... 35
12 Conguring for Cisco Unied Communications Manager 9.. 36
13 Avaya IP Ofce Integration Guide............................................. 40
14 Troubleshooting.......................................................................... 47
15 Software Conguration.............................................................. 48
16 Remote Mount Beacon/Strobe Installation.............................. 49
17 S-1000/S-1050/S-2000 Installation Instructions....................... 50
18 Maintenance Schedule............................................................... 52
19 Locating Unit Serial and Part Numbers.................................... 54
20 Warranty...................................................................................... 55
21 Download Information............................................................... 56

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-162-Epage 4 of 56
Centry®
Administrator Guide
2 Introduction
Thank you for choosing Centry®for your Code Blue application. Centry®is a compact Help Point®
featuring a hands-free speakerphone, IP color camera and station identication light. It has full
duplex capabilities and runs on PoE or 12V DC power. It is mounted with vandal resistant screws for
security.
2 Button Flush Mount 1 Button Surface Mount1 Button Flush Mount 2 Button Surface Mount
Other features include:
• Powered by EmerComm®
• Ring-lit piezoelectric buttons
Call Privacy Laws
Some states require all parties to be aware that they are being recorded. Code Blue phones offer
the ability to play a message stating that the caller is being recorded and giving the caller the option
to continue or end the recorded call.

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-162-Epage 5 of 56
Centry®
Administrator Guide
3 Getting Started
This guide contains information and a general overview for Centry, including applications, installation
and wiring.
Centry Series Features
• 1- and 2-button congurations
• SIP protocol support
• Station Beacon Light for visual identication
• 3 Ethernet ports
• 3 auxiliary N.O. input contact closures
• 3 auxiliary N.O. output contact closures
• NEMA 3S Compliant
• UL 60950-22 Compliant
• Contemporary faceplate design, with multiple ADA compliant lettering choices with Braille
Type 1 Button Flush 2 Button Flush 1 Button Surface 2 Button Surface
Width (in) 4.5 4.5 4.75 4.75
Height (in) 10 10 10.25 4.5
Depth (in) 3.125 3.125 2.875 2.875
Weight (lbs) 4444
Op. Temp. (°F) -40F - +158F
(-40°C - +70°C)
-40F - +158F
(-40°C - +70°C)
-40F - +158F
(-40°C - +70°C)
-40F - +158F
(-40°C - +70°C)
Centry Faceplate Tools
1. T10 pin Torx driver.
Part Part Number
Trim Ring 40002
Speaker N/A
Mic Assembly N/A
Light N/A
Curb Mount 41461
Piezoelectric Button N/A
Indoor 24V AC to 12V DC Adapter Cord 41598
Outdoor 24V AC to 12V DC Adapter Cord (rated for -30 to +70 °C) 40525
Centry Mounting Screws (4pk) 40004

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-162-Epage 6 of 56
Centry®
Administrator Guide
Flush Mount Drawing
FRONT VIEW
SIDE VIEW
BOTTOM VIEW
BACK VIEW
CENTRY
2 BUTTON
CENTRY
1 BUTTON

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-162-Epage 7 of 56
Centry®
Administrator Guide
Surface Mount Drawing
FRONT VIEW
SIDE VIEW
BOTTOM VIEW
BACK VIEW
CENTRY
2 BUTTON
CENTRY
1 BUTTON

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-162-Epage 8 of 56
Centry®
Administrator Guide
4 Installation Instructions
Legal Considerations
Video and audio surveillance can be regulated by laws that vary
from country to country. Check the laws in your local region before
using this product for surveillance purposes.
Liability
Every care has been taken in the preparation of this document.
Please inform Code Blue Corporation of any inaccuracies or omis-
sions. Code Blue cannot be held responsible for any technical or
typographical errors and reserves the right to make changes to the
product and manuals without prior notice. Code Blue makes no
warranty of any kind with regard to the material contained within
this document, including, but not limited to, the implied warranties of
merchantability and tness for a particular purpose. Code Blue shall
not be liable or responsible for incidental or consequential damages
in connection with the furnishing, performance or use of this mate-
rial. This product is only to be used for its intended purpose.
Intellectual Property Rights
Code Blue Corporation has intellectual property rights relating to
technology embodied in the product described in this document.
This product contains open source code that also contains ad-
ditional open source libraries.
Equipment Modifications
This equipment must be installed and used in strict accordance with
the instructions given in the user documentation. This equipment
contains no user-serviceable components. Unauthorized equipment
changes or modications will invalidate all applicable regulatory
certications and approvals.
Trademark Acknowledgments
Code Blue and Centry products are registered trademarks or trade-
mark applications of Code Blue Corporation in various jurisdictions.
All other company names and products are trademarks or registered
trademarks of their respective companies.
Regulatory Information
Electromagnetic Compatibility (EMC)
This equipment has been designed and tested to fulll applicable
standards for:
• Radio frequency emission when installed according to the
instructions and used in the intended environment.
• Immunity to electrical and electromagnetic phenomenon
when installed according to the instructions and used in its
intended environment.
USA
This equipment has been tested using a shielded network cable
(STP) and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interfer-
ence when the equipment is operated in a commercial environment.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruc-
tion manual, may cause harmful interference to radio communica-
tions. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required
to correct the interference at their own expense. The product shall
be connected using a shielded network cable (STP) that is properly
grounded.
Canada
This digital apparatus complies with CAN ICES-3 (Class A). The
product shall be connected using a shielded network cable (STP)
that is properly grounded. Cet appareil numérique est conforme à la
norme NMB ICES-3 (classe A). Le produit doit être connecté à l’aide
d’un câble réseau blindé (STP) qui est correctement mis à la terre.
Safety
This product complies with 62638-1/UL 60950-1 and 62638-1/UL
60950-22, Safety of Information Technology Equipment. The product
shall be grounded either through a shielded network cable (STP) or
other appropriate method. The power supply used with this product
shall fulll the requirements for Safety Extra Low Voltage (SELV)
and Limited Power Source (LPS) according to IEC/EN/UL 60950-1.
This unit complies with IP54/NEMA 3 and IEC 61969-3 Class 1
specications.
Warranty
Code Blue Corporation provides a limited warranty on this product.
Refer to your sales agreement to establish the terms. In addition,
Code Blue’s standard warranty language, as well as information
regarding support for this product while under warranty, is available
at www.codeblue.com/support/downloads.
In Case of Breakdown
In case of system breakdown, discontinue use and contact Tech
In Case of Abnormal Operation
If the unit emits smoke or an unusual smell, if water or other foreign
material enters the enclosure, or if you drop the unit or damage the
enclosure, power off the unit immediately and contact:
(800) 205-7186, option 2.
Disposal and Recycling
When this product has reached the end of its useful life, dispose
of it according to local laws and regulations. For information about
your nearest designated collection point, contact your local authority
responsible for waste disposal. In accordance with local legislation,
penalties may be applicable for incorrect disposal of this waste.
This guide should contain all the information needed for your
application. If any further information is needed, please contact
Support
Should you require any technical assistance, please contact Code
Blue. Visit codeblue.com to:
• Download user documentation and software.
• Find answers to resolved problems in the FAQ database.
• Report problems to Code Blue Technical Support via email

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-162-Epage 9 of 56
Centry®
Administrator Guide
Safety Information
Hazard Levels
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which, if not avoided, could result in damage to property. Other message levels
Important indicates signicant information that is essential for the product to function correctly. Note:
Indicates useful information that helps in getting the most out of the product.
Other Message Levels
Important
Indicates signicant information that is essential for the product to function correctly.
Note
Indicates useful information that helps get the most out of the product.
Safety Instructions
WARNING
• Code Blue products shall be installed by trained professionals.
NOTICE
• Code Blue products shall be used in compliance with local laws and regulations.
• Store the Code Blue product in a dry and ventilated environment.
• Do not install the product on unstable brackets, surfaces or walls.
• Use only applicable tools when installing Code Blue products.
• Do not use chemicals, caustic agents, or aerosol cleaners other than those tested and recom-
mended by Code Blue.
• Use only accessories that comply with technical specications of the product. These can be
provided by Code Blue or a third party.
• Use only spare parts provided by or recommended by Code Blue.
• Do not attempt to repair the product by yourself. Contact Code Blue or your Code Blue re-
seller for service.
Transportation
NOTICE
• When transporting a Code Blue product, use the original packaging or equivalent to prevent
damage to the product.

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-162-Epage 10 of 56
Centry®
Administrator Guide
What’s Included
Quantity Part Description
1 Centry®Help Point®
1 Enclosure (Surface or Flush)
4 Security Screws
2 Knockout Covers
1 Faceplate / Circuit board with Integrated IP Color Camera and Beacon Light
Centry faceplate tools needed for installation:
1. Drill and screws to mount unit to wall.
2. T10 pin Torx driver.
Basic Flush Mount Installation Instructions:
1. The ush mount enclosure will come with no mounting holes. It can be mounted from the
sides, top or bottom. Once your mounting needs have been determined, drill the holes
needed for your specic installation requirements into the ush mount back box.
2. Mark the mounting holes onto the mounting surface. In order to comply with the Ameri-
cans with Disabilities Act (ADA) of 1990, the speakerphone button(s) should be positioned
between 34 and 48 inches from grade level. (Consult an ADA specialist in your area to verify
local and federal guidelines.)
3. Connect earth ground to the provided copper grounding lug using a minimum 14 gauge
conductor.
4. Connect electrical and communications wiring using the wiring diagram below.
5. Follow all federal and local codes that apply.
6. Attach faceplate to enclosure using four security screws.
Basic Surface Mount Installation Instructions:
1. Open shipping box and remove Centry unit.
2. Remove four security screws with T10 Torx driver.
3. Separate Centry from enclosure and set aside carefully.
4. Mark the mounting holes onto the mounting surface. In order to comply with the Ameri-
cans with Disabilities Act (ADA) of 1990, the speakerphone button(s) should be positioned
between 34 and 48 inches from grade level. (Consult an ADA specialist in your area to verify
local and federal guidelines.)
5. Drill all marked holes.
6. Secure the housing to the wall – If you are securing to drywall, utilize drywall screws and
anchors. If you are securing to metal, utilize sheet metal screws. If you are securing to brick,
use Tapcon screws. Fasten all screws securely.
Important: Ensure that conduit is aligned with wiring.
Table des matières
Autres manuels Code Blue Téléphone

Code Blue
Code Blue IP1500 Manuel utilisateur

Code Blue
Code Blue IP2501-s Manuel de service

Code Blue
Code Blue IP5000 Manuel utilisateur

Code Blue
Code Blue CB RT Manuel de service

Code Blue
Code Blue LS2000 Manuel

Code Blue
Code Blue CB 2 Series Manuel de service

Code Blue
Code Blue IA3100 Manuel de service

Code Blue
Code Blue IP5000 2.0 Series Manuel de service

Code Blue
Code Blue IP5000 Guide de démarrage rapide

Code Blue
Code Blue IA4100 Manuel de service