1.ECO ModBus map ; Appendix 1. ECO ModBus map
Holding
registers (4x) Unit/Value Description
1Status
2Application state 0=normal (home), 1=away
3Not used
4 Temperature setpoint
211 Date.year Not able to set via modbus
212 Date.month Not able to set via modbus
213 Date.day Not able to set via modbus
214 Clock.hours Not able to set via modbus
215 Clock.minutes Not able to set via modbus
216 Clock.seconds Not able to set via modbus
2000 Week timer master
2001 Week program1
2002 Not used Must be 1
2003 Week program 1
- Comfort start time
NOTE ! Must be dividable by 15
2004 Week program 1
- Comfort end time
NOTE ! Must be dividable by 15
2005 Week program 1
- Comfort temperature
NOTE ! Must be dividable by 5 (0,5°C)
2006 Week program 1 -
Economy temperature
NOTE ! Must be dividable by 5 (0,5°C)
2008 Not used Must be 1
2009 Week program 2 - Com-
fort start time
NOTE ! Must be dividable by 15
2010 Week program 2 - Com-
fort end time
NOTE ! Must be dividable by 15
2011 Week program 2 - Com-
fort temperature
NOTE ! Must be dividable by 5 (0,5°C)
2012 Week program 2 -
Economy temperature
NOTE ! Must be dividable by 5 (0,5°C)
2013