CLIMATEMASTER WATER-SOURCE HEAT PUMPS
4ClimateMaster Water-Source Heat Pumps
Genesis GR Series
Revised: 9 August, 2011
General Information
Inspection - Upon receipt of the equipment, carefully
check the shipment against the bill of lading. Make
sure all units have been received. Inspect the
packaging of each unit, and inspect each unit for
damage. Ensure that the carrier makes proper notation
of any shortages or damage on all copies of the freight
bill and completes a common carrier inspection report.
Concealed damage not discovered during unloading
must be reported to the carrier within 15 days of
receipt of shipment. If not filed within 15 days, the
freight company can deny the claim without recourse.
Note: It is the responsibility of the purchaser to file
all necessary claims with the carrier. Notify your
equipment supplier of all damage within fifteen (15)
days of shipment.
Storage - Equipment should be stored in its original
packaging in a clean, dry area. Store units in an upright
position at all times. Stack units a maximum of 3 units
high.
Unit Protection - Cover units on the job site with either
the original packaging or an equivalent protective
covering. Cap the open ends of pipes stored on the
job site. In areas where painting, plastering, and/or
spraying has not been completed, all due precautions
must be taken to avoid physical damage to the units
and contamination by foreign material. Physical
damage and contamination may prevent proper start-
up and may result in costly equipment clean-up.
Examine all pipes, fittings, and valves before installing
any of the system components. Remove any dirt or
debris found in or on these components.
WARNING! To avoid the release of refrigerant into the
atmosphere, the refrigerant circuit of this unit must be
serviced only by technicians who meet local, state, and
federal prociency requirements.
WARNING! All refrigerant discharged from this unit must
be recovered WITHOUT EXCEPTION. Technicians must
follow industry accepted guidelines and all local, state,
and federal statutes for the recovery and disposal of
refrigerants. If a compressor is removed from this unit,
refrigerant circuit oil will remain in the compressor. To
avoid leakage of compressor oil, refrigerant lines of the
compressor must be sealed after it is removed.
CAUTION! To avoid equipment damage, DO NOT use
these units as a source of heating or cooling during the
construction process. The mechanical components and
lters will quickly become clogged with construction dirt
and debris, which may cause system damage.
WARNING!
WARNING!
WARNING!
CAUTION!
Safety
Warnings, cautions, and notices appear throughout this
manual. Read these items carefully before attempting
any installation, service, or troubleshooting of the
equipment.
DANGER: Indicates an immediate hazardous situation,
which if not avoided will result in death or serious
injury. DANGER labels on unit access panels must be
observed.
WARNING: Indicates a potentially hazardous situation,
which if not avoided could result in death or serious
injury.
CAUTION: Indicates a potentially hazardous situation
or an unsafe practice, which if not avoided could result
in minor or moderate injury or product or property
damage.
NOTICE: Notification of installation, operation, or
maintenance information, which is important, but which
is not hazard-related.
WARNING! The EarthPure®Application and Service
Manual should be read and understood before attempting
to service refrigerant circuits with HFC-410A.