Adjustment
When the batteries are first installed, the LED indicator light will
flash for 5 seconds (approx. 1s/flash). After this, the dispenser
is now in “setting mode”. If there is no activation of the sensor
window whilst in “setting mode” within 30 seconds, the “setting
mode” will be locked and factory settings will be used.
To get back into “setting mode”, press and hold the setting
button on the bottom of the dispenser for 15 seconds. The LED
indicator light will flash for 5 seconds (approx. 1s/flash). After
this, the dispenser is now in “setting mode ” for 30 seconds.
1. Adjustment of Sensor Distance
Whilst in “setting mode”, press and hold the setting button on
the bottom of the dispenser for 5 seconds. The LED indicator
light will start flashing. Place your hand under the sensor
window at the distance where you require activation to be until
the LED indicator light switches off (please note this distance
should be between 5-15cm from the sensor window). The
sensor adjustment is now complete.
2. Adjustment of Soap Volume per Sensor Activation
Whilst in “setting mode”, press the setting button on the bottom
of the dispenser twice (on the first press the LED indicator light
comes on, after the second press the LED indicator light will
start to flash). Whilst the LED indicator light is flashing put your
hand under the sensor window. The dispenser will give out
liquid in 0.8ml shots (for a maximum of 8 times) until you
remove your hand from the sensor window. Once the hand is
removed the dispenser is set. Depending upon when you
remove your hand from the sensor window you can set the
amount of soap per sensor activation to be between 0.8ml and
~ 6.5ml.
1. Open the upper lid using the supplied key
2. Insert 6 x AA alkaline batteries as per the section of this
manual “battery change”
3. Remove the tank cover and fill the tank with the required
amount of liquid soap. Make sure any spillages are removed from
the outside of the tank
4. Replace the tank cover, ensure the battery box is in its correct
place and close the upper lid, locking it with the supplied key
5. To activate, place your hand under the sensor window. When
the sensor receives the signal the LED indicator light will flash
and the soap will be dispensed automatically.
6. Please note – when first used after a soap refill, you may need
to activate the sensor a few times to pass the soap through the
system from the tank.
Note:
Please remove the protective cover on the sensor window
before using
Remove the tank cover, pour in
the liquid soap, remove any
spilled soap from the outside of
the tank