4
3. Description of the Fog-MaxTM
The Fog-MaxTM w/DMX is CITC’s latest fogging system. No other comparable
machine delivers a thicker, whiter output of 30,000 cfm (850m3/minute) of digitally
controlled fog. New and improved, the Fog-MaxTM can produce longer on high than
the stiffest competition. Accurate temp control makes shut down history. It now has a
quieter pump with a 1500 watt heating head, a 1-channel DMX on board, remote
control cycle-timer and hanging bracket. Best bet for professional fog. Uses water-
based CITC fogging fluid, regular, long-lasting or low-ground. The extra dry fog leaves
no mess, no residue and can be fully controlled with DMX.
The following sequence produces fog:
1. The fog generator is preheated for 7 – 8 minutes.
2. The pump is controlled from 0 – 100% output by the Remote Cycle-Timer
Controller or by DMX.
3. At 100% output. (3 o’clock on Volume Control) the unit will produce heavy fog
continuously without delay
4. At highest output or Blast, the unit will produce a heavy fog for up to 30 minutes
without delays. After 10 minutes fog generator is again warmed up and again
ready to produce fog.
4. Safety instructions
WARNING: Read and understand all labels and operating
instructions before attempting installation.
oNever open the machine without disconnecting power lead first!
Risk of electrical shock- This device is supplied with a grounding conductor. To
reduce risk of electrical shock, connect only to properly grounded, grounding type
receptacles. Never remove the third prong from the plug.
oThis machine requires a 110VAC/20A circuit for operation (or a 230VAC/10A circuit for
the 230VAC machine). The Fog-MaxTM draws approximately 15 amps at 110 VAC (8
amps at 230VAC). During Fog-MaxTM operation this circuit should be dedicated to the
Fog-MaxTM. If you have any doubts about the capacity or grounding of your existing
circuits, consult a qualified electrician.
oBe sure area around fogger is dry before applying electrical power.
oMake sure that your unit is pointed in a direction that leaves a 10ft (3m) open area out
in front. Place the front of the machine away from direct contact with electrical
instruments and people. Close output is very hot and wet..
oNever operate the pump without fluid passing through the tube. This could cause the
pump to overheat and damage the piston. Operating the pump without fluid is not
covered under warranty.
oFluid is very slippery when spilled. Care in keeping any drips or spills cleaned up is
necessary.
oDo not store Fog-MaxTM in freezing conditions.