CHU-EN.UPS-68.MNL.Lithium V2.0.Rev1.00/2022
WARNING : Please Charge Battery of UPS 12 Hours
Battery Need Recharging if has not used for Long Period of Time, Battery
will Start Self - Discharging which may Result in a short Service Life or the
Battery may even Cause Damage Battery Incase Out of Warranty Period
Period Battery & UPS. Be careful Location around UPS in Environment in
High Temperature, Heat, Fire and Dust, That Result in Reduced Service
Life of Battery
-
UPS.
Please followed this Caution Warning Instructions to
Achieve Maximum Service Life.
Line Interactive UPS with Stabilizer
CONNECT EQUIPMENT TO UPS
PLACE LOCATION THE UPS
Inspect items inside box:
User’s Manual & Warranty Card
UPS & Packaging Material
Mains Power Cord
Program & Communication(Option)
Examine the packing carton for damage. Notify your dealer immediately if damage
is observed. Store the packing in a safe place for possible future trans-shipment of
the UPS.
Place location the UPS on a sturdy, dry surface in a wellventilated area away from
direct sources of heat. Leave at least 100mm clearance all around the UPS to provide
adequate ventilation.
CONNECT UPS TO POWER LINE
Connect the Power Cord, to a verified Grounded 3-wire Receptacle. Do not power the
UPS using a Surge Suppressor or Power Strip. The utility power Turn ON.
UPS INDICATORS AND CONTROLS
Product contains Voltages and Battery, which are Potentially
Hazardous.
Qualified Service Personnel should perform all Repairs.
Do not try to Open the cover and to service the
system yourself,
No user serviceable parts inside.
Refer servicing to qualified Service Personnel only and warranty Condition
Product has its own internal energy source
(Battery).
Outlet receptacles may be Risk Electrical even
when the product is
not connected to an AC supply.
In case of Fire Risk, Please change the Fuse & Reset Breaker with
the same Kind and same Rate.
Product is intended for indoor use IP20 only.
Kindly note to avoid excessive Heat, Dust, Humidity
CAUTION AND WARNING
i
Enable the UPS by turning on the Power ON/OFF switch, which is situated on the
front panel.
The UPS is now ready to use. Switch on your equipment and you are ready to function.
BATTERY MAINTENANCE / BATTERY CHARGING
ON / OFF SWITCH
Turn ON this button to supply power
to the
UPS outlets. To switch off power
to the UPS
outlets
Turn OFF the switch. This switch is
situated
on the front panel of the UPS.
BACKUP INDICATOR
(Battery Level Bright & Beep )
The buzzer beeps every 8 seconds.
The battery is powering the UPS outlets.
The expected runtime for a typical personal
computer (PC) is about 10 to 40 minutes.
LOW BATTERY INDICATION
(Battery Level Low Bright & Quick Beep)
The buzzer beeps fast whenever the
battery is near the end of its runtime.
Promptly save your data and exit all
applications and shutdown the operating
system.
AC NORMAL INDICATOR
(3Digit of Volt Out, No Beep)
The UPS is supplying conditioned
utility power to its outlets.
UPS
BATTERY
OVERLOAD
PROTECTION
AUTOMATIC
VOLTAGE
REGULATION
AC SURGE
PROTECTION
Buck / Boost
FEATUREFEATURE
Connect the Power Cord, to a verified grounded 3-wire receptacle. Do not power
the UPS using a surge suppressor or power strip. The utility power Turn ON.
(UPS Plug 3 Outlet, No Backup for Printer 1 Outlet)
i
Pb
CAUTION :
BEFORE INSTALLATION & OPERATION
Do not connect a surge suppressor,
power strip, or extension cord to the
UPS outlet.
100 ÁÁ.
100 ÁÁ. 100 ÁÁ.
IP20
• Avoid direct sunlight.
•
Avoid excessive humidity or liquids.
•Avoid excessive heat.
• Avoid excessive dust.
• IP20 Indoor Use
The UPS is intended for indoor use only. Although your UPS is very rugged, its
internal components are not sealed from the environment. Kindly note the following.
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
Laser Printer
V2.0
CB
4.5A
/
250V
Press to Reset
10A
250V~
INPUT 220V 50Hz
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
CHUPHOTIC
ªÙâ¿·Ô¤
ÂÙ¾ÕàÍÊ
OVERLOAD INDICATION
The Yellow LED flashes, with continuous
beeping. UPS protects itself at this time.
Please move some load.
Connect a Laser Printer or any
non-computer peripherals to UPS
outlets.