Chord DAVE Manuel utilisateur

Chord Electronics Limited
DAVE
DIGITAL / ANALOGUE CONVERTER
OPERATING INSTRUCTIONS
- !-1

Chord Dave connection diagram
- !-2

Chord Dave Digital to Analogue Converter Operating Instructions
Mains connection instructions
Please ensure that the IEC mains lead is correctly terminated:
WARNING
DAVE MUST BE EARTHED AT ALL TIMES VIA ITS OWN MAINS LEAD.
FAILURE TO DO THIS MAY BE HAZARDOUS.
Plug the supplied lead into the AC inlet and then switch the unit on.
Cleaning and care instructions
Dave requires no special care other than common sense. Spray window cleaner (clear type) may be
used (if first sprayed onto a soft cloth) to remove surface blemishes such as finger marks from the
metal casing. Never spray directly onto the converter and never use abrasive cleaning, use only a lint
free soft cloth.
There are no user serviceable parts in Dave. It should be serviced only by Chord Electronics Limited or
their expressly approved service agents.
NB: This unit must be ventilated at all times with at least 5cm space around and above the unit.
Switching on Dave
The master power switch can be found at the rear of the device. When switching the unit on there will
be a 20 second delay where the display will show ‘Mute’. This is to allow the unit to program, and for
the system to settle.
WARNING
YOU MUST SWTICH DAVE ON FIRST BEFORE ANY PREAMPLIFIER OR POWER
AMPLIFIER. FAILURE TO DO THIS COULD RESULT IN YOUR EQUIPMENT ENTERING
PROTECTION MODE OR DAMAGE.
- !-3

Audio Outputs
There is a pair of stereo balanced outputs via Neutrik XLR style connectors and one pair of stereo
unbalanced outputs via gold plated RCA phono style connectors. Each of these will drive down to a
50ohm load. This means that Dave will work with all known pre-amplifiers and is able to drive very
long audio cables without difficulty. Both audio outputs work at the same time so this allows Dave to
be connected to two pre-amplifiers if needed.
As Dave features a digital volume control it can also be connected directly to a power amplifier
without the need for a preamplifier.
Digital Inputs
Dave features eight digital input formats. They can all be used at the same time and are individually
selectable using the left/right selector buttons on the top panel or via remote control.
These consist of four separate 75ohm-SP/DIF2 BNC (BNC1,2,3,4) inputs, one AES balanced XLR
input (AES), two Plastic Fibre Optic (Opt1,2) inputs, and a single USB B type connector (USB).
Display
The display is split into 4 zones. The top half of the screen shows the selected input, sample frequency
and volume level.
Depending on the display mode the background colour will change to clearly indicate the sample
frequency and volume level. In the example below the USB input is shown running at 44.1KHz
indicated by the red background.
The sample rate colours are as follows:
- !-4

The middle section of the screen shows the setup options which can be accessed using the menu mode.
You have 4 menu options for PCM/DSD mode, Phase, HF filter, and Display mode.
The bottom part of the screen indicates Digital Preamplifier mode, DAC mode, or Headphone mode.
In display mode 2 you only have black and white theme where the sample rate and volume colours are
not shown.
Display mode 3 appears much like mode 1. The single difference between the two is that display mode
3 features an aesthetically pleasing fading blue background.
Display mode 4 is largely similar to display mode 1. However, after 30 seconds, the screen will enter
‘screensaver mode’ and will shut off until a function button is pressed.
- !-5

Manual Controls
Dave can be operated manually by the controls on the top of the unit, or it can be operated using the
supplied remote control. Using these controls you can select the digital input, adjust the volume level,
and make changes to the setup options.
The top control panel features 4 push buttons and a rotary volume control.
The volume control rotates left or right to decrease or increase the volume level. Pushing it down will
mute or unmute the output.
The left/right buttons select the digital input and this is displayed on the top right of the screen.
The up/down buttons select the setup options at the bottom of the screen. Once an option is highlighted
the left/right buttons will change the setting.
- !-6

Remote Control
Dave is supplied with a full system remote control that will work for all Chord products, televisions,
and DVD players. Full instructions can be found in the System Remote Manual supplied, but for the
purposes of controlling Dave the main functions are listed on the next page.
!
Press the key to begin controlling Dave.
Selecting the digital input
Press the Line- or Line+ keys on the centre control to cycle through the inputs.
- !-7

Adjusting the volume
Press the Vol+ button on the centre control to increase the volume, press the Vol- button on the centre
control to decrease the volume.
Mute
Press the key to mute Dave.
To un-mute
Press the key again.
Standby:
Press the button. You do not have to flick the master switch on the rear of the device.
Please note that when switching the unit on from standby there will be a 20 second delay where
the display will show ‘Mute’. This is to allow the unit to program, and for the system to settle.
Setup Menu
Press the BAL+ / MENU key on the remote to enter the setup menu. The press the VOL+/VOL- to
select the option. Press Line+ / Line – to make changes.
- !-8

Setup Options
To make setup changes you first need to enter menu mode. Either press the up or down button on the
top panel, or press the menu button on the remote, and then press the vol+ or vol – button. As you press
the buttons each item on the setup menu will be highlighted. When you reach the desired setting just
press the left or right (line + or line – on remote) buttons to alter the setting.
You have 4 setup options:
HF Filter On or Off – This turns on a special high frequency filter to reduce noise
Phase Pos or Neg – You can optimise the absolute signal phase on the analogue outputs to positive or
negative.
DSD+ or PCM+ Mode – Toggle between the two modes.
Dual Data Mode - Dave supports dual data mode on its BNC inputs. This is where a 176kHz data rate
is supported by sending a left 88kHz signal and a right 88kHz signal via separate BNCs. For example
this function is supported with our Blu CD Transport.
To operate DAVE in dual data mode you should connect the left BNC to ‘input 1 BNC’ and the right
BNC to ‘input 2 BNC’. Following this you should select BNC1 on the menu and, upon successful
pairing, a letter ‘D’ will appear with the sample rate. To operate a second dual data input please connect
the left channel BNC to input 3 and the right channel BNC to BNC input 4.
Display – There are 4 display background colour options. You can toggle between black and gold (1),
black and white (2), blue/green (3) and black and gold message mode (4). This final option 4 will
switch off the display after a few seconds unless the sample rate, input or volume changes.
- !-9

DAC Mode
Dave can be used with the inbuilt volume control to drive an amplifier directly but should you wish to
use it with a preamplifier or AV amplifier it can be switched to DAC Mode.
Simultaneously pressing both left and right buttons on the top panel will activate DAC mode and this
will be indicated on the bottom right of the display. DAC mode fixes the output level to 3dB (3V
unbalanced, 6V balanced line level output) and deactivates the volume control along with some remote
control functions. This mode is remembered even when the power is turned off.
To turn off DAC mode simply press both left and right buttons at the same time until you see ‘Digital
Pre’ on the bottom right of the display.
Please note that inserting headphones into the front jack socket will automatically deactivate DAC
mode. This is so that you can adjust the volume level for safe headphone listening.
Please note: Never use DAC mode when connected directly to a power amplifier as you could risk
permanent damage to your loudspeakers due to the high volume level.
DSD+ or PCM+ Mode
Dave has two menu options specifically tailored for PCM or DSD playback. You can play both PCM
and DSD music using either mode, but each one is specifically optimised for a particular format. In
order to cycle between each mode please highlight the segment and press both left and right navigation
buttons simultaneously for one second.
PCM+ - Use this for PCM playback up to 768KHz. DSD playback up to DSD256 is also supported but
it is decimated and not optimised in this mode.
DSD+ - Use this for DSD64, 128, and 256 (single, dual and quad speed) playback. There is no
decimation. PCM can still be played and this mode is ideal for streaming video with audio as it has a
lower delay.
Before changing modes please stop music playback and mute your amplifier to allow the clocks
to resynchronise and avoid incorrect playback. Please note that when switching between PCM+
or DSD+ modes there will be a 20 second delay where the display will show ‘Mute’. This is to
allow the unit to program, and for the system to settle.
Headphone Mode
Dave features a very high quality headphone output which is able to drive both in ear monitors and also
on ear headphones from 8 to 800 ohms. Simply plug in to the front socket using a ¼” (6.35mm) jack
plug. Dave will automatically switch to headphone mode and mute the main outputs.
Headphone mode stores a separate volume level for your headphones and does not effect the main
volume on the analogue outputs.
In headphone mode you can select from 4 crossfeed settings to suit your listening experience and
headphones. Use the up/down buttons or remote control to select the crossfeed option then use the left/
right button to change the setting from crossfeed 1 to 4.
- !-10
Autres manuels pour DAVE
3
Table des matières
Autres manuels Chord Convertisseur de média

Chord
Chord 2go Fiche technique

Chord
Chord 2 Qute Manuel utilisateur

Chord
Chord MOJO 2 Manuel utilisateur

Chord
Chord DAVE Manuel d'instructions

Chord
Chord Hugo Manuel d'instructions

Chord
Chord Hugo TT 2 Manuel d'instructions

Chord
Chord Hugo TT 2 Manuel utilisateur

Chord
Chord Hugo M Scaler Manuel utilisateur

Chord
Chord Hugo M Scaler Manuel utilisateur

Chord
Chord Hugo M Scaler Manuel d'instructions