Preface
Welcome to use CGOLDENWALL steam generator and select one
of ST-135 controller to control it. The steam generator, which has the
reasonable design, stable function and beautiful appearance, uses the
international advanced technology. It equips with special room body to
form the complete set of sauna, which can relax people’s muscle,
eliminate fatigue, and excrete the toxin in the body. Sauna can make
people refreshed and has the function of health care.
To install, operate and maintain the machine safely and correctly,
please read the instructions carefully and keep it in case.
Please pay attention to these when use it;
·Old people, pregnant women, the diabetic, the cardiac and the
people for the other unhealthy reasons can not use the equipment
unless under the guidance of doctor.
·Do not smoke, do sports and drink alcoholic drinks when do
sauna.
. Please leave the shower room as soon as possible when feel
uncomfortable, sick or tired.
·Please take good care of children.
·It is necessary to install a ventilated fan to let in the fresh air.If
you have any questions, please contact us directly by email.
We will guide you online to help you solve the problem sooner
and better.
✉Email:sunflowersmile20130401@hotmail.com

3
CONTENTS
Parameters............................................................................................4
Instructions for Installation..................................................................5
Steam Generator Location...................................................................6
Water Inlet pipe....................................................................................8
Steam Outlet pipe.................................................................................9
Drain pipe and Auto drain valve..........................................................9
Steam nozzle.......................................................................................11
Wiring Connection..............................................................................12
Controller Install Guide......................................................................16
Temperature Probe Install..................................................................17
Start the steam generator....................................................................18
Controller Operation Guide................................................................18
Maintenance operation guidance.........................................................20
Troubleshooting Guidance .................................................................22

4
Parameters
1, models, basic parameters and size of appearance in table 1
Table 1
Power(KW)
Volt/phase number
Size(length*width*height)(
in)
3
220/2
11.8×5.1×9.1
4.5
220/2
12.6×5.1×13.2
5
220/2
12.6×5.1×13.2
6
220/2
15.6×5.9×15.6
7
220/2
17.5×6.5×15.6
8
220/2
17.5×6.5×15.6
9
220/2
17.5×6.5×15.6
10.5
220/2
19.7×7.9×20.5
12
380/3
19.7×7.9×20.5
15
380/3
19.7×7.9×20.5
18
380/3
19.7×7.9×20.5
2, the basic parameters of controllers and the size in table 2
Table 2
Model
time
(minute)
Range of
temperature
Size(length*width*height)
(mm)
ST-135
NO
95 - 131℉
100×100×40

5
Instructions for Installation
The steam generator has been carefully assembled and tested, please
fix in accordance with national laws and regulations. And be fixed by the
people who has local or national plumber certificate. Turn off all the
power in fixing, and make sure that if the type applies for the shower
room. Please look at table 3
Table 3 Technical parameters
Power
(KW)
Room size
(ft3)
voltage
(V)
Phase
number
Copper
wire cable
size (mm²)
Copper wire
cable size
(AWG)
Breaker
required
(A)
3
70~105
220V
2
2.5
12
20
4.5
105~140
220V
2
4
12
32
6
175~210
220V
2
6
8
40
9
315~350
220V
2
10
8
60
10.5
315~420
220V
2
10
8
60
12
360~455
380V
3
6
10
25
15
420~560
380V
3
6
9
30
18
560~735
380V
3
6
8
40

6
Steam Generator Location
1, the steam generator should be fixed in the wall or on the floor firmly,
Select a location as near as practical to the shower room. Typical
locations include: closet, vanity cabinet, climate controlled attic or
basement. In the process of fixing, install the machine on a vertical
wall, release the two screws on the cover, move the cover and then fix
the machine using the holes on the top right and left. Signs should be
put in the obvious place and the generator should be put in the flexible
place for maintaining. Please refer to the figure 1 to fix.
2, do not install the machine outside, or the place where is wet, hot or
the place where is easy for being frozen or eroded. Do not install it
near paint, thinner, or gas. Install it in a dry and ventilation place.
3, the generator can only be installed horizontally.Up in the direction
indicated by the arrow. Otherwise, it is strictly forbidden to boot.
4, locate the steam bath generator within 32 feet of the shower room.The
standard length of the cable for connecting the control to the steam
generator is 32 feet. The steam generator and control must be located
accordingly.
5, do not install steam bath generator inside shower room.
6, do not install steam bath generators or pipes in an unheated attic
or any place where water may freeze.
7, do not install the steam bath generator near flammable or
corrosive materials or chemicals (such as gasoline, paint thinner,
etc.). Must avoid installation in areas with high chlorine
concentration (such as swimming pool room).
8, Provide a minimum of 12 inches at both ends and top of the steam
generator or as required for servicing.

7
attic floor(insulated)
suitable for installation
Controller (suitable
be installed outdoors)
closet
(suitable for installation)
basement
(suitable for installation)
steam generator
Controller (suitable
be installed outdoors)
steam jet
under the wash basin
(suitable for installation)

8
Pipe installation
Water source pipe and steam pipe should be installed in accordance
with national laws and regulations. The installation should be done before
sealing walls.
1, Water inlet pipe--the water inlet pipe is connected with the DN15 pipe
(1/2 NPT). And a DN15 metal hose is connected to the water inlet and
water supply valve of the machine.
Connect to cold water .
Provide a shut off valve in the water supply line upstream of the
steam bath generator.
Do not overheat inlet solenoid valve while welding connections.
Overheating will damage parts.
Flush inlet water line thoroughly before connection to unit.
Strainer recommended to install upstream of feed water connection
The best performance water pressure should be 15 to 20 PSIG.
Reduce pressure as required if necessary.
As required by local codes, install an approved backflow preventer.
Do not use PEX , PVC tubing or Aluminum-plastic tube

9
2, Steam outlet pipe---steam pipe should use copper pipe longer than
DN15 (ferrous metal and galvanized pipe was not allowed to use for it
can make the shower room rust and discolor). The length of steam
pipe was no more than 3 meters. It should be used for keeping warm
if it is longer than 3 meters. (Please refer to figure 3)
1. Do not install any valve in steam line. Flow of steam must be
unobstructed.
2. Use 1/2” brass pipe or copper tubing from unit to steam head as
permitted by codes.
3. Insulate steam line using pipe insulation rated 250˚ F or higher.
4. Pitch steam line 1/4” per foot towards steam head or steam
generator to avoid valleys and trapping of condensation.
NOTE: Running the steam line down and then up will create a steam
trap blocking the flow of steam.
NOTE: A 1.5 ”hole in the shower room is required to mount the
steam head
3, Drain pipe and automatic drain valve( 1 ⁄2’’ NPT)
It is necessary to install a DN15 pipe
A drain valve is provided to facilitate servicing. Provide a drain line
connection with the steam bath generator.Unit drains by gravity. The auto

10
drain is automatically turned on after the controller is turned off for about
15 minutes, but it must be ensured that the main power supply is not
turned off.
1. Plumbing to be performed by a qualified plumber and shall be in
accordance with applicable national and local codes. Steam generator
drains by gravity. A drain line should be lower than the Auto Drain
System assembly . The Auto Drain System valve outlet is 1/2”NPT.
Check plumbing code for receptor, trap and vent requirements.
2. Use copper or brass nipple 1/2”NPT x 3 , 1 ⁄2”or longer (not
supplied) to connect Auto Drain valve. An arrow on the bottom of the
Auto Drain indicates the direction of flow
Table des matières