Ceridian Dayforce Touch Clock Manuel utilisateur

Ceridian’s
Dayforce Touch Clock
User Manual [ENG]
July 2018
WARNING: This manual contains information on limitations regarding product use,
function and information on the limitation and liability of the manufacturer. Read the
entire manual carefully.
Read and save these instructions! Follow all warnings and instructions
specified within this document and/or on the equipment. Always
ensure you obtain the latest version of the User Guide. Updated
versions of this User Guide are available by contacting your Ceridian
HCM administrator.

DF Touch
Page 2 of 32
1IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of fire, electric shock and/or injury, observe the
following safety precautions:
•Do not spill any type of liquid on the equipment.
•Do not attempt to service this product yourself. Opening or
removing the cover may expose you to dangerous voltage or
other risk. Refer servicing to qualified service personnel. Never
open the device yourself.
•Do not touch the equipment and its connected cables during an
electrical storm; there may be a risk of electric shock.
2REGULAR MAINTENANCE AND TROUBLESHOOTING
Keep your DF Touch Clock in optimal condition by following all the
instructions that are included within this manual and/or marked on the
product.
3HANDLING PRECAUTIONS
•Do not subject the touchscreen to mechanical shock (e.g.,
dropping or striking). Mechanical shock could damage the glass
display.
•If the touchscreen glass is damaged, the liquid crystal fluid
inside could leak out. Avoid contact with the liquid crystal fluid.
If the liquid crystal fluid comes into contact with your skin or
clothes, promptly wash it off using soap and water.
•Do not apply excessive force to the display surface or adjoining
areas. Excessive force will distort the image on the display.
•Do not use hard or sharp implements to operate the
touchscreen. Operating the touch screen with implements
harder than a finger could scratch the display.

DF Touch
Page 3 of 32
•Do not attempt to disassemble the LCD Module.
4CLEANING
If the display surface is contaminated, moisten a use a soft cloth and
isopropyl alcohol to clean it. Other cleaners such as ketone (e.g.,
acetone), and/or aromatic solvents (e.g., benzene und toluene) may
damage the display. Do not use abrasives, thinners, solvents or aerosol
cleaners (i.e., spray polish). Any aromatic solvents, keytones, etc. that
may enter through holes in the touch panel will cause damage.
Keep the ventilation slots clear of obstructions, dust buildup and liquids.
Do not spray liquids directly into the unit; avoid liquids entering into the
unit.
WARNING: This equipment shall be installed and used within an
environment that provides the pollution degree max 2 and over-
voltages category II non-hazardous locations, indoor only. It is designed
to be installed, serviced and/or repaired by service persons only [service
person is defined as a person having the appropriate technical training
and experience necessary to be aware of the hazards to which a person
may be exposed in performing a task and of measures to minimize the
risks to other persons]. The end user cannot replace any of the parts
within the unit, other than the battery (which is optional and is not part
of the standard offering). These safety instructions should not prevent
you from contacting the installer or Dayforce HCM administrator to
obtain any further clarification and/or answers to your concerns.
5MAINTENANCE
With normal use, the system requires minimal maintenance. We
recommend, however, that the standby batteries be replaced every 3-5
years.

DF Touch
Page 4 of 32
6SPECIFICATIONS
This document describes the technical specifications of the DF Touch
clock terminal.
6.1 Display and Keypad
Capacitive Touch, 7 inch, 1024x600 pixels, hardened glass surface.
6.2 Processor
CPU: 1GHz Dual Core ARM Cortex A9
RAM: Memory 1GByte 528 MHz SoDIMM, Non-volatile FLASH
memory 8GByte
6.3 Environment
Operating temperature: 0° to 40°C (32° to 104°F)
Storage temperature: -30° to 80°C (-22° to 176°F)
Humidity: 10% to 90% relative humidity, non-condensing.
6.4 Power Supply
Input Power Jack:
24 VDC ±5%, 0.75 A, 20 W maximum
2.5mm barrel connector, center positive.
Power over Ethernet (PoE)
IEEE 802.3at Type2, absolute operating input voltage 42.5-57VDC,
nominal draw 10Watts, max 20Watts.
Optional: External power supply
Input voltage 110-250 VAC, 0.5 A, 50/60Hz
Optional: Battery backup with Charger
Discharge life: 1.5 hours at 23°C (73°F)

DF Touch
Page 5 of 32
Charge time: 16Hrs (on first use)
Charging (normal): 0° to 45°C (32° to 113°F)
Storage: -20° to 35°C (-4° to 95°F)
Discharging (battery): -20° to 60°C (-4° to 140°F)
6.5 Operating System
Android 4.0.4 (ICS)
Android 6.0.1 (Marshmallow) –Available Q4 2018
6.6 Application Programs
Dayforce Clock Program
Dayforce Self Service
6.7 Enclosure
Plastic ABS/PVC Composite
6.8 Wall-mount Options
10 Degree metal
40 Degree metal (extra cost –good for camera use)

DF Touch
Page 6 of 32
6.9 Internet Connectivity
IEEE 802.3 10/100BASE-T/1000BASE-T Ethernet using TCP/IP
communication protocol and CAT-5 cable, cable lengths between
the terminal and an Ethernet network hub can be up to 328 wire-
feet.
DHCP (Dynamic Host Configuration Protocol) is implemented to
assign IP addresses for the terminal, host and router. Static IP
addresses may also be assigned manually via the touch screen.
The terminal supports the use of DNS servers to convert host
names to host IP addresses in both DHCP and static IP modes.
Optional Wi-Fi 802.11 b/g/n
•Only 2.4Ghz bandwidth is supported –5Ghz is not
supported
6.10 Camera
Integrated camera with 3 Megapixels resolution and torch flash.
6.11 LED
Three-color LED (red, green, blue) for status display
6.12 External ports
Two USB ports for specific and Ceridian-certified external devices:

DF Touch
Page 7 of 32
Ports for model A7, A8

DF Touch
Page 8 of 32
Ports for model A2-A6
6.13 Optional Readers & Modules (extra cost)
Fingerprint Biometric reader
Barcode slot reader (visible or infra-red light)
Magnetic slot reader
Proximity reader (125Khz or 13.5Mhz –for HID Proxpoint™,
iClass™, Mifare™, NFC)
6.14 Barcode Reader
Symbologies decoded:
•Standard Code 39
•Full ASCII Code 39
•Code 11
•Code 93

DF Touch
Page 9 of 32
•Code 128
•Codabar
•Interleaved 2 of 5
•Industrial 2 of 5
•Matrix 2 of 5
•UPC-A/UPC-E
•EAN-8/EAN-13
•EAN/UCC 128
•China Postal Code
•MSI Plessy Code
•UK Plessy Code
•IATA Code
•Telepen Code
Resolution 6 mils (PCC –90%)
Print contrast ration > 60%
Bars must be centered 11mm from the edge of the card and should
be 10mm high or more. There must be at least 6mm white space on
both sides of the bar code.
6.15 Terminal Block
Optional relay output and digital input.
Two Form C relay outputs; 1A at 30V DC
Two Optically Isolated Inputs; 24V DC, 1.2Kohm
6.16 Certifications
CE Mark, FCC Part 15 Class A

DF Touch
Page 10 of 32
6.17 Time Synchronization
Terminal uses web service to synchronize its time with Dayforce
servers.
6.18 Dimensions (Approximate)
11 in (28cm) wide
5.5 in (14cm) high
2.25 in (6cm) deep without wall-mount
3 in (7.5cm) deep with 10 degree wall-mount
Weight about 4.4 lbs (2Kg) with packaging
7BATTERY PACK (OPTIONAL)
A battery pack is not shipped with the clock, but can optionally be
added if requested.
To use the battery, you must first plug it into the clock; place the battery
socket lightly over the battery plug as pictured in the figure below.
Gently tilt the connector tab slightly towards the battery while pushing
down with your finger. The socket will clear the plastic housing and slide
down.
Table des matières
Autres manuels Ceridian Horloge
Manuels Horloge populaires d'autres marques
Silicon Laboratories
Silicon Laboratories SI5324 Manuel utilisateur

Heathkit
Heathkit GC-1005 Manuel utilisateur

Oregon Scientific
Oregon Scientific PRYSMA RMR221P Manuel utilisateur

Andrew O'Malley
Andrew O'Malley DOTKLOK Manuel utilisateur

ALGE-Timing
ALGE-Timing ASC3 Manuel utilisateur

Bodet
Bodet Profil 960 Manuel utilisateur