CENTURION SYSTEMS V Series Manuel utilisateur

page 1 www.CentSys.com
®
®
®
V-Series
Electrical Setup & Commissioning Guide
Centurion Systems (Pty) Ltd www.CentSys.com

After-sales
multi-language
Technical Support
from 07h00 to 18h00
UTC+2
Monday to Friday
Manufacture to
international
quality standard
ISO 9001:2008
100%
testing of
products
In-house
R&D
development
team
Centurion Systems (Pty) Ltd reserves the right to make changes to the products described in this
manual without notice and without obligation of Centurion Systems (Pty) Ltd to notify any persons
of any such revisions or changes. Additionally, Centurion Systems (Pty) Ltd makes no representations
or warranties with respect to this manual. No part of this document may be copied, stored in a retrieval
system or transmitted in any form or by any means electronic, mechanical, optical or photographic,
without the express prior written consent of Centurion Systems (Pty) Ltd.
1986 1990 1995 1999 Today
COMPANY PROFILE
Company Prole
Sales and technical support
to Africa, Europe, Asia,
the Americas, Australia
and the Pacic
page 2

www.CentSys.com
Contents
CONTENTS
SAFETY
FIRST IMPORTANT SAFETY INSTRUCTIONS
1. General Description
1.1. Lightning Protection
2. Icons Used in this Manual
3. Electrical Setup
4. Wiring Diagram Symbols
5. Wiring Diagram - Master Motor (MTR M)
6. Wiring Diagram - Slave Motor (MTR S)
7. Wiring Diagram - Wired Closing Safety Beams
8. Wiring Diagram - Double Wired Closing Safety Beams
9. Wiring Diagram - Wired Opening Safety Beams
10. Wiring Diagram - Wireless Closing Safety Beams
11. Wiring Diagram - Double Wireless Closing Safety Beams
12. Wiring Diagram - Wireless Opening Safety Beams
13. Wiring Diagram - External Radio Receiver & Loop Detector
14. Wiring Diagram - Electric Gate Lock/Maglock
15. Wiring Diagram - Holiday Lockout Keyswitch/Keypad
16. Wiring Diagram - Pedestrian Keyswitch/Keypad
17. Wiring Diagram - G-SPEAK Classic+ Intercom
18. Wiring Diagram - G-SWITCH-22 Monitoring & Control Device
19. Wiring Diagram - Status LED
20. Wiring Diagram - Solar Panel
21. Wiring Diagram - Pillar Light Push button (Normally-Open)
22. Wiring Diagram - Charger & Pillar Light Connections
22.1. Fuse Protection
23. Seting up Additional Features
24. Controller Menu Structure
25. Controler Features
page 5
page 7
page 8
page 9
page 10
page 15
page 16
page 17
page 18
page 19
page 20
page 21
page 22
page 23
page 24
page 25
page 26
page 27
page 28
page 29
page 30
page 31
page 32
page 33
page 34
page 35
page 36
page 40
page 3

page 4 www.CentSys.com
CONTENTS
26. Factory Defaults Schedule
26.1. SouthAfricanStandardProle-ZA
26.2. CEStandardProle
26.3. UL325StandardProle
27. Description of Terminal Functions
28. Diagnostics
28.1. Diagnostic LEDs
28.2. Gate Status LED Indication
28.3. LCD Display
28.4. Buzzer Feedback
29. Installation Handover
page 56
page 56
page 59
page 62
page 65
page 68
page 68
page 69
page 70
page 71
page 72

page 5www.CentSys.com
IMPORTANT SAFETY INSTRUCTIONS SAFETY FIRST
ATTENTION
To ensure the safety of people and possessions, it is important that you
read all the following instructions.
Incorrect installation or incorrect use of the product could cause
serious harm to people and pets.
The installer, being either professional or DIY, is the last person
on the site who can ensure that the operator is safely installed, and that
the whole system can be operated safely.
Warnings for the Installer
CAREFULLY READ AND FOLLOW ALL INSTRUCTIONS before beginning to install
the product.
• All installation, repair, and service work to this product must be done by a suitably
qualiedperson
• Do not activate your gate opener unless you can see it and can determine that its area of
travel is clear of people, pets, or other obstructions
• NO ONE MAY CROSS THE PATH OF A MOVING GATE. Always keep people and objects
away from the gate and its area of travel
• NEVER LET CHILDREN OPERATE OR PLAY WITH THE GATE CONTROLS, and do not
allow children or pets near the gate area
• Securealleasily-accessedgateopenercontrolsinordertopreventunauthoriseduseof
the gate
• Do not in any way modify the components of the automated system
• Donotinstalltheequipmentinanexplosiveatmosphere:thepresenceofammablegas
or fumes is a serious danger to safety
• Beforeattemptinganyworkonthesystem,switchoelectricalpoweranddisconnectthe
batteries
• Themainspowersupplyoftheautomatedsystemmustbettedwithanall-poleswitch
withcontactopeningdistanceof3mmorgreater.Useofa5Ahydraulicbreakerwithall-
pole circuit break is recommended
• Makesurethatanearthleakagecircuitbreakerwithathresholdof30mAistted
upstream of the system
• Nevershort-circuitthebatteryanddonottrytorechargethebatterieswithpowersupply
units other than that supplied with the product, or by Centurion Systems (Pty) Ltd
• Make sure that the earthing system is correctly constructed, and that all metal parts of
the system are suitably earthed
• Safetydevicesmustbettedtotheinstallationtoguardagainstmechanicalmovement
risks such as crushing, dragging and shearing
IMPORTANT
SAFETY INSTRUCTIONS

www.CentSys.compage 6
• Never run the operator directly from the battery! Doing so will cause
damage to the operator. Only run the operator from the V-Series
Controller
• A moving gate can cause serious injury or death!
Keep clear! The gate may move at any time!
Do not allow children to play in the area of travel of the gate or
operate the gate
IMPORTANT SAFETY INSTRUCTIONSSAFETY FIRST
• Itisrecommendedthatatleastonewarningindicatorlightbettedtoeverysystem
• Alwaystthewarningsignsvisiblytotheinsideandoutsideofthegate
• The installer must explain and demonstrate the manual operation of the gate in the case
of an emergency, and must hand the User/Warnings guide over to the user
• The installer must explain these safety instructions to all persons authorised to use this
gate, and be sure that they understand the hazards associated with automated gates
• Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as
such materials are potential sources of danger
• Disposeofallwasteproductssuchaspackingmaterials,worn-outbatteries,etc.,
according to local regulations
• Always check the obstruction detection system and safety devices for correct operation
• Centurion Systems (Pty) Ltd does not accept any liability caused by improper use of the
product, or for use other than that for which the automated system was intended
• This product was designed and built strictly for the use indicated in this documentation.
Any other use, not expressly indicated here, could compromise the service life/operation
of the product and/or be a source of danger
• Everythingnotexpresslyspeciedintheseinstructionsisnotpermitted

page 7www.CentSys.com page 7
GENERAL DESCRIPTION SECTION 1
The VANTAGE, VERT-X and VECTOR2 operators have been designed to safely and
cost-eectivelyautomateawidevarietyofswinggates,fromsinglelight-domesticswing
gates to heavy industrial double swing gates.
Thefail-safeandfully-redundantPositionandCollisionDetectionsystemhasbeen
designed and tested to set the standard in safety of operation and to provide an
unparalleled level of reliability and durability in operation.
ThegateTravelLimitsaremanagedbyasealeddouble-redundantopto-electronicsystem
thathasbeendesignednotonlytoensureultra-reliableoperation,butalsotoensure
precise position and trajectory control. This enables very accurate and reliable collision
detection to ensure safe operation even under trying conditions.
The V-Series electronic Controller has been designed to be easy and intuitive to use,
with helpful instructions on the status of the operation being given both during and after
theinstallation.Italsohasbuilt-indiagnosticproceduresthatcanverifyeveryaspectof
the control card onsite.
SomeoftheadvancedfeaturesoeredbytheV-Series Controller are:
• Fullyautomatedsingle-buttonLimitSetupforsingleanddoubleswinggates
• FullgraphicsLCDdisplayprovidesanintuitiveuserinterfacewithbuilt-indiagnosticsto
speed up and simplify the installation process
• Separate safety inputs for infrared beams or photocells on both the closing and opening
directions of the gate
• Advancedclosed-loopspeedcontroltomaintainsafeandreliableoperationoninclined
gates and under windy conditions
• Fully-congurablegateRunProles
• Selectable and adjustable Autoclose with push button override
• Pedestrian Opening (partial opening) with Autoclose
• Free-exitinput
• Positive Close Mode
• Positive Open Mode
• Support for Inward and Outward opening gates
• Multiple Modes of Operation
• Solenoid lock drive output up to 2A
• Holiday Lockout
• A status LED output to indicate the Gate Status remotely
• Pillar Light Control
• Leaf Delay is selectable for either gate leaf
• Onboardcode-hoppingreceiverwithselectiveaddinganddeletingofremotecontrols
1. General Description

page 8 www.CentSys.com
SAFETY FIRSTIMPORTANT SAFETY INSTRUCTIONS
DECLARATION OF CONFORMITY
SECTION 1 GENERAL DESCRIPTION
This guide covers all aspects pertaining to the electrical setup of your new VANTAGE,
VERT-X or VECTOR2swinggateoperators,includingwiringandconguringthevarious
features and functions available on the controller.
1.1. Lightning Protection
The V-Series Controller utilises the same proven surge protection philosophy that
is used in all of our products. While this does not guarantee that the unit will not
be damaged in the event of a lightning strike or power surge, it greatly reduces the
likelihood of such damage occurring. The earth return for the surge protection is provided
via the mains power supply earth. In order to ensure that the surge protection is
eective,itisessentialthattheunitisproperlyearthed.

page 9www.CentSys.com
SAFETY FIRSTIMPORTANT SAFETY INSTRUCTIONS
DECLARATION OF CONFORMITY
ICONS USED IN THIS MANUAL SECTION 2
2. Icons Used in this Manual
This icon indicates tips and other information that could be useful during the
installation.
This icon denotes variations and other aspects that should be considered during
installation.
This icon indicates warning, caution or attention! Please take special
note of critical aspects that MUST be adhered to in order to prevent
injury.

page 10 www.CentSys.com
3. Electrical Setup
1. Always check that the circuit breaker in the electrical panel is in the OFF position,
andthatallhigh-voltagecircuits(morethan42.4V)arecompletelyisolatedfromthe
mains supply before doing any work.
2. Ensurethatalllow-voltagesystems(lessthan42.4V)aresuitablyprotected
from damage, by disconnecting all sources of power such as chargers and
batteries before doing any work.
3. All electrical work must be carried out according to the requirements of all applicable
local electrical codes.
3.1. Secure V-Series
Wall Box to Wall
SecuretheV-SeriesWallBox
to the wall using the most
appropriate means.
Be sure to position the Wall Box
so as not to cause any hazards
during and after the installation.
Preferably mount the Wall Box:
FIGURE 1
Mount the V-Series Wall Box preferably at
a comfortable working height
3.2. Connect all Wiring
Connect all the required cables to
the Controller; see pages 16 to 33.
• Out of direct sunlight
• At a comfortable
working height
• Away from garden
sprinklers, etc.
• To allow easy access
even when the gate is
open
FIGURE 2
SECTION 3 ELECTRICAL SETUP
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels CENTURION SYSTEMS ouvre-porte

CENTURION SYSTEMS
CENTURION SYSTEMS VANTAGE 400 SMART Manuel utilisateur

CENTURION SYSTEMS
CENTURION SYSTEMS V400 Manuel utilisateur

CENTURION SYSTEMS
CENTURION SYSTEMS D 10 Manuel utilisateur

CENTURION SYSTEMS
CENTURION SYSTEMS VERT-X Manuel utilisateur

CENTURION SYSTEMS
CENTURION SYSTEMS R6 Manuel utilisateur