1. GENERAL INFORMATION
Thank you for purchasing Combustible Leak Detector.
Read though the instruction manual before operation
for correct and safe usage. Please store and retain
this instruction manual for future reference.
2. FEATURES
Combustible Leakage Detector is extremely useful as
a general purpose tool in any environment where
gasoline, propane, natural gas or fuel oil is used. This
unit uses a newly developed semi-conductor sensor
which is extremely sensitive to variety of general
used combustible.
Microprocessor Control with advanced digital
signal processing.
Multi color visual display.
High-Low leak sensitivity selector.
Low battery indication.
Semiconductor gas sensor.
Detection of combustible gas.
Carrying case included.
15.5” (40 CM) flexible stainless probe.
Reference Leak source included.
Ambient concentration reset.
Application:
Detect leaks in automobile exhaust and fuel
system.
Detect leaks in liquid or gas fired heating systems.
Safety checks at propane filling stations.

COMBUSTIBLE GAS DETECTOR
3
Search for arson residue (detects accelerants).
Detect fuel in marine bilges.
Check manholes/sewers for safety.
Check for cracked heat exchangers.
Detect solvent residue.
3. SPECIFICATION
Detectable Gases:
Gasoline, propane, natural gas or fuel oil.
Alarm Method:
Buzzer, Tricolor LED bar Indicator.
Sensitivity: Variable, as low as 5ppm(gasoline)
Power Usage:
4 AA size (6V DC) Alkaline Batteries
Snake Tube length: 40cm (15.5”)
Dimension / Weight:
173 x 66 x 56 mm (approximately 400g)
Accessories:
Alkaline batteries (AA) X 4 pcs
User manual, leak check bottle, carry case.
Battery Life:
Approximately 40 hours normal use.
Auto power OFF: 10 minutes
Warm-Up Time: Approximately 90 seconds
Operating Temperature & Humidity:
0 ~40 °C, < 80% RH

COMBUSTIBLE GAS DETECTOR
4
Storage Temperature & Humidity:
-10 ~60 °C, < 70% RH
Altitude: < 2000M (6500’)
4. OPERATION GUIDE
(1) The combustible leak detector unit is not equipped
with anti-explosive designs and measures. Do not use
this unit in the environment with the burnable gases.
(2) There are some environmental conditions that
might cause error reading:
Pollutant places.
Large temperature variation.
Places with high wind velocity.
Organic solvent, adhesive vapor, fuel gas and
vesicant will cause abnormal response from the
sensor. Try to avoid the environment involved with
this substance.
Places fill with too much to combustible Gas.
Note: Although the unit will respond to high levels of
carbon monoxide, it should not be used as a detector
for this gas in normal room or working atmospheres.
It is used to pinpoint a leak as described in the
operating instruction.

COMBUSTIBLE GAS DETECTOR
5
5. PARTS & CONTROL
5-1 Panel Description
○
9
COMBUSTIBLE
GAS DETECTOR

COMBUSTIBLE GAS DETECTOR
6
○
1Sensor
○
2Sensor Protector
○
3LED Leak Indicators
○
4Sensitivity Lo Button
○
5Sensitivity Hi Button
○
6Low Battery Indicator
○
7Power On/Off & Reset Button
○
8Battery Cover
○
9Battery Cover Screw
5-2 LED Leak Indicator Definition:

COMBUSTIBLE GAS DETECTOR
7
6. GETTING STARTED
6-1 Installing Batteries
Loose the screw and remove the battery
compartment door located on the bottom of the
instrument as shown below (Fig.1).
Install 4 “AA” size alkaline batteries.
Reinstall the battery cover by aligning it with the
handle.
When the battery power is running low, the Red LED
Low Battery indicator illuminates. The batteries should
be replaced as quickly as possible.
4 “AA” size
alkaline batteries
Fig.1

COMBUSTIBLE GAS DETECTOR
8
6-2 Automatic Ambient Reset Feature
This combustible leak detector features an Automatic
Ambient Reset function that sets the unit to ignore
ambient concentrations of combustible.
Automatic Ambient Setup - Upon initial power on,
the unit automatically sets itself to ignore the level
of combustible present at the tip. Only a level, or
concentration, greater than this will cause an alarm.
CAUTION!
Be aware that this feature will cause the unit to
ignore any combustible present at turn on. In other
words, with the unit off if you place the tip up to a
known leak and switch the unit on, no leak will be
indicated!
Ambient Reset Feature - Resetting the unit during
operation performs a similar function; it programs
the circuit to ignore the level of combustible
present at the tip. This allows the user to 'home-in'
on the source of the leak (higher concentration).
Similarly, the unit can be moved to fresh air and
reset for maximum sensitivity. Resetting the unit
with no combustible present (fresh air) causes any
level above zero to be detected.

COMBUSTIBLE GAS DETECTOR
9
6-3 Feature Sensitivity Adjustment
The Instrument provides two levels of sensitivity.
When the unit is switched on, it is set to the high
sensitivity level by default.
To change the sensitivity, press the key.
When the key is pressed, the visual display will
momentarily show the two left LED's (green)
indicating Low Sensitivity level is selected.
To switch back to High Sensitivity, press the
key. The two right LED's (red) will light momentarily
indicating high Sensitivity level is selected.
7. OPERATING PROCEDURE
WARNING!
1. Do not use the instrument in an area of
extremely high level of combustible gas.
2. The gas/vapor of organic solvent might
interfere with the function of the unit. During
detection, please eliminate the influence of the
organic solvent.
3. In order to ensure correct operation and
indication, the unit should be switched on and
warm-up in non-contaminated atmosphere.
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Détecteur de gaz populaires d'autres marques

Macurco
Macurco GD-6 Manuel utilisateur

Evikon
Evikon E2632 Manuel utilisateur

Critical Environment Technologies
Critical Environment Technologies CGAS-A Series Manuel utilisateur

MSA
MSA altair 5 Manuel utilisateur

DOD Technologies
DOD Technologies ChemLogic CL96 Manuel utilisateur

DEGA
DEGA NS III LCD Series Manuel utilisateur