CDL tecora BRAVO plus Manuel utilisateur

Bravo Pump
Plus / Basic
USER'S MANUAL
MANUAL

USER MANUAL: BRAVO Plus / Basic
REF. MU DSM 46 Version : 2a Pages : 2 of 49 Date : 2019.03.18
Date Written by Date Validated by
2019.03.18
VLC 2019.03.18
VLC
2019.03.18 2a All Modification into CDL
2017.04.24 2 All New presentation + add timer GRASSLIN
2006.04.01 1.3 All
DATE Version PAGE Modifications

This document is the property of Tecora and can not be duplicated without permission
Ref : EN MU DSM 46 V2 Page 3 of 49
INDEX Page
1
Introduction........................................................................................................................................... 5
1.1
Warranty Conditions and Installation................................................................................................ 5
1.2
Installation.......................................................................................................................................... 6
1.2.1 Waste disposal ............................................................................................................................... 6
1.3
Power Supply and Precautions.......................................................................................................... 6
1.4
Models and Main Characteristics ...................................................................................................... 7
2
BRAVO Plus ........................................................................................................................................... 9
2.1
Description......................................................................................................................................... 9
2.1.1
Keyboard and Display.............................................................................................................. 10
2.2 Standard delivery.................................................................................................................................. 11
2.3 Accessories .......................................................................................................................................... 11
3
Quick Sampling Guide ........................................................................................................................ 12
3.1
Program the sampling...................................................................................................................... 12
3.1.1 Flowrate Setting ........................................................................................................................... 12
3.1.2 Timed Sampling, set the sampling Start and Duration................................................................. 13
3.1.3 Volumetric Sampling, set the sampling Start and volume to realize ............................................ 14
3.2
Data displayed during the sampling ................................................................................................ 15
3.3
Pause during the sampling. ............................................................................................................. 16
3.3.1 Timed Sampling ........................................................................................................................... 16
3.3.2 Volumetric sampling ..................................................................................................................... 16
3.4
Sampling Final Report ..................................................................................................................... 17
4 Utility Menu ................................................................................................................................................. 18
4.1 Test EV................................................................................................................................................. 18
4.2 Set datary ............................................................................................................................................. 18
4.3 Set the Baud Rate ................................................................................................................................ 19
4.4 Download the memory using the RS232.............................................................................................. 19
4.4.1 Measure final report ..................................................................................................................... 19
4.5 Delete Memory ..................................................................................................................................... 21
4.6 Measure Test and Calibrations............................................................................................................. 21
4.7 Load Default Calibration....................................................................................................................... 22
5 Sequential and Intermittent Sampling ...................................................................................................... 23
5.1 Programming a sequential sampling. ................................................................................................... 23
5.2 Program an intermittent sampling. ....................................................................................................... 25
6 Alarm messages and anomalies ............................................................................................................... 26

This document is the property of Tecora and can not be duplicated without permission
Ref : EN MU DSM 46 V2 Page 4 of 49
7 Measuring sensors Characteristics.......................................................................................................... 26
8 Remote control functions via SMS ........................................................................................................... 27
8.1 SMS Commands .................................................................................................................................. 27
8.1.1 Start the sampling ........................................................................................................................ 27
8.1.2 Sampler actual status................................................................................................................... 28
8.2 Anomalies in the SMS transmission..................................................................................................... 28
9. BRAVO Basic ............................................................................................................................................. 29
9.1 Instrument Description.......................................................................................................................... 29
9.2 Operation Instructions .......................................................................................................................... 30
9.2.1 Power ........................................................................................................................................... 30
9.2.2 Power On...................................................................................................................................... 30
9.2.3 Flowrate Setting ........................................................................................................................... 30
9.3 Timer Programming.............................................................................................................................. 31
9.3.1 Timer Description ......................................................................................................................... 31
9.3.2 First Program................................................................................................................................ 31
9.3.3 Normal Operation ......................................................................................................................... 32
9.3.5 Programming the device .............................................................................................................. 32

This document is the property of Tecora and can not be duplicated without permission
Ref : EN MU DSM 46 V2 Page 5 of 49
1 Introduction
1.1 Warranty Conditions and Installation
Warning: when you receive the instrument and the accessories from the packaging and verify their
integrity, otherwise contact Tecora or your distributor immediately.
Test
The instruments are tested in our laboratories at Villebon sur Yvette ZI La Prairie, and a test
certificate is released.
Warranty
The warranty cover the instruments for 12 months from the test passed date.
The warranty doesn’t cover the following:
•damages to the instruments occurred during the transport
•damages to the instruments due to negligence or wrong use
•wearable parts (batteries, motors, filters)
The technical service on the instruments is intended in our Service Department.
Email: customer.ser[email protected]

This document is the property of Tecora and can not be duplicated without permission
Ref : EN MU DSM 46 V2 Page 6 of 49
1.2 Installation
The Bravo sampler is a portable instrument suitable for outdoor ambient samplings.
The protection rate isn’t enough to allow outdoor operations with rain presence.
1.2.1 Waste disposal
Packaging: all the packaging materials are to be considered as non-toxic and non-hazardous
special waste and as such must be disposed of in accordance with current legislation.
Equipment
The crossed-out wheeled bin means that in European Union the product is to be
considered AEE (electrical and electronic equipment) and must be taken to separate
collection at the product end-of life.
This applies to your device but also to any enhancements marked with this symbol.
Do not dispose this product as unsorted municipal waste.
1.3 Power Supply and Precautions
For safety reasons and for the optimal operations, a good power supply with the ground and no
disturbs is needed. In case you use an extension cable for the power supply, it’s necessary that
you connect only the ECHO PM to this power supply cable.
On the power supply line of the ECHO PM there is an anti-disturb filter.
The socket type is a two phases plus the ground, with protection fuse on each phase and a bipolar
ON/OFF switch with “ON” LED.
Power Supply:
220 Vac 50 Hz: from 202 to 253 Vac 50 Hz;
115 Vac 50/60 Hz: from 106 to 132 Vac 50/60 Hz;
For the power, absorption and fuses used, please refer to the Chapter Technical Characteristics
Power Losses
The instrument is equipped with an internal battery and electronic circuits that protects the
sampling from power losses, anyway, disturbs caused by bad electrical contacts may create critical
situations and compromise the good operation.
Attention
To maintain the efficiency of the Ni-Cd internal battery, it’s necessary to recharge it periodically
even if the sampler is not used.
It’s recommended to charge the battery every two months if the instrument is not used connecting
it to the power supply for at least 24 hours.

This document is the property of Tecora and can not be duplicated without permission
Ref : EN MU DSM 46 V2 Page 7 of 49
1.4 Models and Main Characteristics
BRAVO M plus BRAVO H plus
Diaphragm Pump
Range : 0.15 – 35 l/min
New Controller for samplings program,
display data and logger
Sequential Interface : Optional
Piston Pump
Range : 1 – 60 l/min
New Controller for samplings program,
display data and logger
Sequential Interface : Optional
BRAVO M Basic BRAVO R Basic BRAVO H Basic
Diaphragm Pump
Range :
0.15 – 35 l/min
weekly based programmer
Digital Thermometer
3 m
3
/h Rotary vane Pump
Range :
0.2 – 35 l/min
weekly based programmer
Digital Thermometer
6 m
3
/h Rotary vane Pump
Range :
1 – 60 l/min
weekly based programmer
Digital Thermometer

This document is the property of Tecora and can not be duplicated without permission
Ref : EN MU DSM 46 V2 Page 8 of 49
BRAVO Curve caratteristiche (Performance curves)
BRAVO M
BRAVO R
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70
Portata (Flow) qV l/min
Vuoto (Vacuum) KPa
BRAVO H
BRAVO M
BRAVO R
Bravo curve
characteristics
(Performance curves)

This document is the property of Tecora and can not be duplicated without permission
Ref : EN MU DSM 46 V2 Page 9 of 49
2 BRAVO Plus
2.1 Description
1. Membrane keypad and back-lighted display
2. Cover with key-lock
3. Inlet quick connector
4. Vacuum meter in line with the sampler gas
5. Dry Gas Meter
6. Flow rate regulators
7. RS 232 Interface
8. Flow Meters
9. Sequential interface connector (Optional)
10.Power supply socket with lighted switch and protection fuse
1
2
7
8
9
5
3
4
10
6

This document is the property of Tecora and can not be duplicated without permission
Ref : EN MU DSM 46 V2 Page 10 of 49
2.1.1 Keyboard and Display
Keyboard
Pause key
Move the cursor
to the left and
move on upside
raw
Move the cursor
to the right and
skip a raw
Skip a raw
Accept the
selection
Numeric
keyboard
Ce manuel convient aux modèles suivants
6
Table des matières
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur