Carro PH-805-24 Manuel utilisateur

Ultrasonic Humidifier
USER MANUAL
Model: PH-805-24
Warning Notice: Before using
this product, please read this
manual carefully and keep it for
future reference.
The design and specifications are
subject to change without prior
notice for product improvement.
Consult with your dealer or
the manufacturer for details.
Rated voltage: 120V
Rated power: 24W
Frequency: 60Hz
QUESTIONS? CONTACT US.
Email: humidifier@fscarro.com
Tel: 888-253-2374

Page 2
Read This Manual
Inside you’ll find many helpful hints on how to use and maintain your appliance
properly. Just a little preventive care on your part can save you a great deal
of time and money over the life of your appliance. You’ll find many answers
to common problems in the troubleshooting tips - you should be able to fix
most of them quickly before calling customer service. These instructions may
not cover every possible condition, so attention to safety details is required
when operating and maintaining this product.
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the
instructions shown here must be followed. Incorrect operation due to ignoring
of instructions may cause harm or damage. The different levels of risk is shown
by the following indications.
CAUTION
This symbol indicates a hazardous situation, which, if
not avoided, could result in minor or moderate injury.
This symbol addresses practices not related to physical
injury.
NOTICE
This symbol indicates a hazardous situation which, if
not avoided, could result in death or serious injury.
WARNING
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT INSTRUCTIONS
• In the case of power up, do not plug or unplug the power cord with wet hands
to avoid electric shock;
• Do not force the water tank to work in the case of no water;
• Do not add any additives not produced or supervised by the company to the
water tank;
• Do not put or place anything or pets into the water tank;
• Do not add water to the atomization outlet;
• When the humidifier is working, do not touch the water in the water tank or the
parts sank in the water;
• Do not cover the atomization outlet, and please keep it clear above the outlet;

Page 3
IMPORTANT INSTRUCTIONS
• Do not replace the power cord without authorization, or connect the power
cord halfway or use other appliances in parallel;
• Do not place the appliance near water source;
• Do not disassemble, modify or repair internal parts without authorization;
• Do not climb or sit on the appliance;
• Do not directly flush the humidifier with water;
• Do not store flammable or explosive materials around the humidifier;
• Do not place it near heat source;
• Do not turn off the humidifier by unplugging the power cord directly;
• Do not use volatile oil, alcohol, thinner, etc. to clean the machine, otherwise, the
product may be damaged;
• Do not modify the use and function of the product without permission;
• When the power is turned off in low temperature weather, the water must be
drained.
• Do not place the water container on the live product, the water immersing in the
product will weaken the electrical insulation, resulting in Electric shock, fire, etc;
• Please keep a distance of more than 12 inch between the humidifier and other
products;
• Please use purified water for humidification;
• Please do not use a damaged or worn power cord; Do not replace the power
cord without authorization. If the power cord is damaged, it must be replaced
by the manufacturer, its service department or professional from similar
department to avoid danger.
• The power must be cut off in thunderstorm;
• When an abnormal phenomenon (like a burnt smell) occurs, the operation must
be stopped and the power supply is cut off.
• Please unplug the power cord and clean the water tank, when the appliance is
not used for a long time;
• To avoid bacterial growth, please always change the water in the water tank.
• When the appliance is moved, please unplug the power cord to keep the water
tank stable and to prevent the water from overflowing in the water tank;
• If the appliance is tilted when filled with water, be sure to unplug the power
cord immediately and send it for inspection.
• Suitable temperature for this product: 41°F -104°F; relative humidity: less than
80% RH (please fill purified water with water temperature below 104°F).
Matters that may cause minor injury or property damage.
Please unplug the power plug when filling and cleaning.
The power supply must be within the specified voltage range of the product.
CAUTION

Page 4
This humidifier is pre-assembled in factory.
ASSEMBLY
RULES FOR SAFE OPERATION
SPECIFICATIONS
Model Rated
voltage
Rated
frequency
Rated
power Noise Volume
of tank
PH-805-24 120V ~60Hz 24W 38dB 2.11Gal
WARNING
• Please be sure to unplug the power cord before filling water.
• The level of the water added shall not be higher than the highest water level;
• Please be not to add the water in the atomization outlet when the water is
added;
• Please do not add additives like essential oil, perfume, drug, etc. to the water.
• Please use the purified water below 104°F(Do not use distilled water).
NOTICE
• The following are the design parametersof PH-805-24 themeasured
parameters are subject to the product;
• The humidification amount will vary, depending on the temperature and
humidity in the room.
• Actualhumidification amount isnot less than 90% the standard 390mL/h.

Page 5
PARTS AND FEATURES
Manual × 1
NOTICE
Water Mist
Guiding Tube
Water Tank
Main Unit
Control Panel
Atomization Outlet
• The pictures of the Manualare for referenceonly, and theactual product in
thepacking box shall prevail.
• The product appearance and function vary with themodel; Please be subject
to the realproduct,with optional reading of the respective function
description.

Page 6
INSTRUCTION FOR USE
Two methods forwater filing
Method A
Fill the water tank directly through the main unit cover. Please use
purified water. Please do not add the water in the atomization outlet.
Method B
Lift the main unit of the humidifier up and fill purified water directly from top
of the water tank.
Atomization Outlet Main Unit Cover
Purified
Water
Purified Water

Page 7
OPERATION INSTRUCTIONS
Buttons Operation
On/Off
Atomization
adjustment
Timing button
1. Shortly press this button to enter the on/idle state.
2. In the on/idle state, press and hold 3 seconds till hear “be-
ep”, the WIFI signal on the screen will blink and enter the
CARRO HOME APP connection mode.
Under working conditions, the humidity and atomization
amount can be set to three levels (small, medium and large).
Press and hold till hear "beep" to enter sleep mode, the
display light will be turned off, and the atomization amount
level automatically switched to level 1 (small).
1.Shortly press in the working conditions, you can cycle to
set the timer function.The timer setting can be 0h→1h→
2h→4h→8h→0h.
2. In the process of setting, the setting timer time will be
displayed first, and then if you do not operate, the timer
will flash 3 times and then switch to display the humidity
of the current environment.
3.The timer time displays in a countdown way. After setting
the timer, if you press the timer button again, the operation
screen will display the remaining time before shutdown,
and then press the timer button again to re-set the timer.
4. After the timer is turned on, press and hold the timer button
for 3 seconds to exit the timer setting state.
NOTICE
Control Panel
• If the indoor temperature is too low or the humidity is too high, and the mist
cannot be fully diffused, it is recommended to reduce the volume of water
mist.
• When humidity setting lower than current humidity, the atomizing mist will
stop within two minutes. In the working state, if there is no operation for more
than 1 minute, the operation screen will automatically enter the light-off sleep mode
The level of atomization remains unchanged.
Operation Part
Display Part

WiFi indicator
light
Humidity On/Off
Humidity Setting. Press once will display "F", and you can
cycle to set the humidity "40%-45%-50%-55%-...-90%-F-
40%"(5%RH gradient). "F" stands for canceling the preset
humidity.
The indicator light is on when the humidifier is shortage of
water.
When connecting to the network, the indicator light is on.
01 small atomization amount
02 medium atomization amount
03 large atomization amount
0h/01h/2h/4h/8h timer
Display the humidity of the environment, such as 60%.
Page 8
CLEANING AND MAINTENANCE
WARNING
Before cleaning or descaling, be sure to unplug the power cord.
Do not use abrasive, corrosive, or flammable cleaners (such as bleach or
alcohol) to clean any part of the humidifier.
The humidifier must regularly clean the scale and debris in the water tank
and sink. It is recommended to clean it once a week.
•
•
•
Water shortage
indicator light
• IMPORTANT TIP: DO NOT leavethe humidifier plugged in for prolonged
periods (i.e. several days or more) without use.
• This causes premature failure of the circuitry. When the humidifier is not in
use, press the control button until the light goesoff, then UNPLUG it.

Lift the main unit cover.
Fig 1 Fig 2 Fig 4 Fig 5
Atomizing Head
Assembly
Lift the main unit up in
the direction of the arrow.
Placed the main unit on the
platform and stabilize it.
Do not turn the main unit upside down.
Cleaning the outer casing
Wipe and clean the surface of the whole machine with a slightly damp soft
cloth. In case of stubborn stains, add a small drop of detergent to clean it,
and then wipe the detergent away.
Tank cleaning
First take out the main unit cover, then lift the main unit upwards, shake
the main unit slightly, so that the water in the mist guiding tube flows back
to the water tank, put the main unit aside, then pour clean water into the
water tank, and add an appropriate amount of detergent for cleaning.
Use a clean cloth to dry the inside and outside of the water tank.
Warning:Do not use a dripping soft cloth to clean the outer casing, or rinse
it with a shower.
Page 9
Clean the outside part
of the machine.
Lift the main unit up in
the direction of the arrow.
Clean the outside part of the machine.
Do not turn the main unit upside down.
Fig 3

Fig 6
Fig 7 Fig 8
Cleaning the inside & outside of the mist guiding tube,and the
atomizing head
1. Rotate counterclockwise to unscrew connecting hose of the main unit
and the atomizing head as shown in Fig 1.
2. Hold the main unit with one hand, press the spring switch of the mist guidi-
ng tube with the other hand at the same time as shown in Fig 2, and remove
the main unit in Fig 3.
3. Rotate the lower cover of the tube clockwise to remove the cover, and
then take out the atomizing head assembly as shown in Fig 4.
4. Clean the dirt inside the tube with a long-handled soft brush(not included)
as shown in Fig 5, and then wash the tube in the sink.
5.Use a screwdriver(not included) to poke the small hole in the back of
atomizing head assembly, and take out the atomizing head for cleaning as
shown in Fig 6, and wipe the center of it with a damp soft cloth.
6.When cleaning the components of the float, first loosen the set screw,
rotate the upper shell of the float clockwise and take it out, and then take
out the foam of the float as shown in Fig 7.
7.Wipe the upper shell of the float with a clean damp cloth, use a soft brush
(not included) to clean the lower part of the float as shown in Fig 8, and then
put it in sink to clean it.
Page 10
Foam
Table des matières
Autres manuels Carro Humidificateur