Cardinal 2XX-EIP Manuel utilisateur

8200-M554-O1 x2XX-EIP
Page 1
2XX-EIP
EtherNet/IP Interface Card
For 200 Series Indicators
(205, 210, 215 and 225)
INSTALLATION MANUAL
8200-M554-O1 Rev A
203 E. Daugherty, Webb City, MO 64870 USA
Printed in USA
03/09
Ph: 417-673-4631 yFax: 417-673-2153
www.cardinalscale.com

8200-M554-O1 x2XX-EIP
Page 2

8200-M554-O1 x2XX-EIP
Page 1
INTRODUCTION
Thank you for purchasing the 2XX-EIP EtherNet/IP Interface Card. This option card for the
Cardinal 200 Series (205, 210, 215 and 225) Weight Indicating Instrument was built with
quality and reliability.
The 2XX-EIP has been designed for the industrial environment where interfacing through an
EtherNet IP network is desired. When coupled with a 200 Series indicator, it can provide the
weight reading and control of multiple scale commands. The interface card resides in the main
enclosure of the indicator and has a 16-pin dual in-line connector to provide an easy
connection to the indicator internal hardware. A single RJ-45 connector is provided to connect
to the EtherNet IP network. The 2XX-EIP supports 10/100 Mbit, full or half duplex operation.
The purpose of this manual is to provide you with a guide through setup and installation of the
2XX-EIP EtherNet/IP interface card. Please read it thoroughly before attempting to install it in
your indicator and keep it handy for future reference.
SPECIFICATIONS
Temperature Range: ........
14qto 104qF (-10qto +40qC)
Network Connections: ......
(1) RJ-45 connector
Diagnostics: ......................
On board LED’s CS (Chip Select), LK
(Link) and ML (Maim Line)
FCC COMPLIANCE STATEMENT
This equipment generates uses and can radiate radio frequency and if not installed and used
in accordance with the instruction manual, may cause interference to radio communications. It
has been tested and found to comply with the limits for a Class A computing device pursuant
to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection
against such interference when operated in a commercial environment. Operation of this
equipment in a residential area may cause interference in which case the user will be
responsible to take whatever measures necessary to correct the interference.
You may find the booklet “How to Identify and Resolve Radio TV Interference Problems” prepared by the Federal
Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C.
20402, Stock No. 001-000-00315-4.
All rights reserved. Reproduction or use, without expressed written permission, of editorial or
pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to
the use of the information contained herein.
While every precaution has been taken in the preparation of this manual, the Seller assumes
no responsibility for errors or omissions. Neither is any liability assumed for damages resulting
from use of the information contained herein. All instructions and diagrams have been
checked for accuracy and ease of application; however, success and safety in working with
tools depend to a great extent upon the individual accuracy, skill and caution. For this reason
the Seller is not able to guarantee the result of any procedure contained herein. Nor can they
assume responsibility for any damage to property or injury to persons occasioned from the
procedures. Persons engaging the procedures do so entirely at their own risk.
PRECAUTIONS
Before beginning installation of this option card, read this manual and pay
special attention to all "WARNING" symbols:
IMPORTANT
ELECTRICAL
WARNING
STATIC
SENSITVE

8200-M554-O1 x2XX-EIP
Page 2
INSTALLATION
Mounting the Option Card
NOTE! Should your indicator come with the option card already installed, the following section
describing mounting, does not apply. Proceed to the Node Address Setup section.
ATTENTION! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC
SENSITIVE DEVICES.
1. Make sure the power to the indicator is OFF.
Unplug the AC power cord.
2. Loosen the gland connector(s) where the AC
power cord and any other cables enter the back
panel of the indicator.
3. Remove the acorn nuts securing the back panel
to the main housing.
4. Lift the back panel from the main housing, taking
care not to stretch the cable and wires between
the panel and main housing. Lay the back panel
on the workbench next to the indicator.
5. Referring to Figure No. 1, locate the threaded
stand-off and the OPTION BOARD connector on
the main board.
6. To install the option card, carefully align the P4
connector (pins on trace side of option card) with
OPTION BOARD connector on the indicator
main board and apply even downward pressure
to the end of the option card at P4.
7. Align the hole in the option card with the
threaded stand-off on the main board and using
the lock washer and screw supplied with the
option card, secure the card to the main board.
8. To attach the ground wire, remove a 6-32 nut
and washer from the corner of the main board.
Refer to Figure No. 2.
9. Connect the ground wire from the option card by
placing the ring terminal over the 6-32 threaded
stud.
10.Reinstall the washer and 6-32 nut and tighten.
Figure No 1
Threaded
Stand-off
Attach
Ground Here
Connector for
OPTION BOARD
Figure No 2

8200-M554-O1 x2XX-EIP
Page 3
INSTALLATION, CONT.
Cable Installation in the Indicator
1. Loosen an unused cable gland connector for the cable.
2. Insert the Ethernet cable (CAT 5 or equivalent) through the gland connector and into the
enclosure.
3. Consult your network administrator for the proper procedure to terminate the cable.
4. After the cable has been terminated, plug the cable into the RJ-45 jack on the 2XX-EIP.
Item #
Description
Item #
Description
1
Status LED’s
4
EtherNet/IP Module
2
Ethernet Connector
5
P2 Expansion Connector
3
P4 Connector (pins on trace
side of board)
6
Ground Wire
2XX-EIP Status LED’S
The 2XX-EIP EtherNet/IP Interface Card contains 3 LED’s to indicate communication status
with the indicator main board.
xCS, Chip Select
xLK, Link
xML, Main Line
If the CS (Chip Select) LED is off, communications may
have been lost between the EtherNet IP module and the
indicator main board. Cycle power (press ON/OFF key
twice) to re-establish communications.
The LK (Link) LED displays the communication status.
It will be on or flashing rapidly when communications
between the 2XX-EIP and the EtherNet IP network is established.
The ML (Main Line) LED will be on to indicate the 2XX-EIP is powered up and running.
IMPORTANT! A load cell connection is required when testing the indicator.
An ERR AL or ERR AH condition will cause the communications from the
main board and the module to be very slow and will inhibit communications
with the EtherNet/IP module.
cc
gg
dd
ee
ff
CS
ML
LK
h

8200-M554-O1 x2XX-EIP
Page 4
RE-INSTALLING THE REAR PANEL
When the installation is complete:
1. Remove the excess cable from the indicator enclosure.
2. Make certain no cables or wires are exposed between the main housing and rear panel
and then place the rear panel onto the main housing.
3. Secure with the acorn nuts removed earlier. Follow a diagonal pattern when tightening
the acorn nuts.
4. Tighten the gland connector nut to seal the cable. Do not over-tighten the connector but
make certain they are snug. DO NOT USE TOOLS! Finger-tighten only! Insure any
unused gland connectors are plugged.
INDICATOR SETUP
No special setup is required on the indicator.
TCP/IP ADDRESS SETUP
On an EtherNet/IP network, each node must be assigned its own unique TCP/IP address. The
2XX-EIP EtherNet IP interface card IP address is set using the Anybus IPconfig Tool utility
provided on the 2XX-EIP Config File CD (8200-M533-O1).

8200-M554-O1 x2XX-EIP
Page 5
CONFIGURE THE PLC USING RSLogix5000
Either create a new project or use an existing, set the program in “Offline” mode. Add the
module to the configuration in the PLC. Start by right click the EtherNet/IP module/bridge in
the I/O configuration, and select “New Module”.
Now a dialogue window will appear. In this dialogue window, select “Generic Ethernet module”
and press OK.

8200-M554-O1 x2XX-EIP
Page 6
CONFIGURE THE PLC USING RSLogix5000, CONT.
In the next dialogue window, RSLogix 5000 will ask for information regarding the
communication to the module. First enter a name for the module. This name will create a tag
in RSLogix5000, which can be used to access the memory location in the PLCs memory
where the data for the module will be stored. With the name entered, press Next.
In the next dialogue box enter a value for the time between each scan of the module, called
Request Packet Interval (RPI). Make sure that “Inhibit Module” isn’t checked. After this, press
Finish.

8200-M554-O1 x2XX-EIP
Page 7
CONFIGURE THE PLC USING RSLogix5000, CONT.
Now the module has been added to the I/O configuration in RSLogix5000. The main screen
will look as follows.
Now go online and download the configuration to the PLC.
1. Select Go Online in the communication menu.
2. A new window will open.
3. Select download.
4. A new window will popup with the question if you actually want to download the
configuration.
5. Select “Download”. The configuration will now be downloaded to the PLC.
Now it’s possible to access the data exchanged by ControlLogix5000 and the module. To do
this, open the “Controller Tags” window and go to monitor tags. Three tags named
“Cardinal_2XX:C”, “Cardinal_2XX:I” and ” Cardinal_2XX:O” should be visible, representing the
three instances configuration, input and output. The configuration instance will be created
even if we selected zero as its size. The Cardinal_2XX:I tag is data coming from the module
and Cardinal_2XX:O tag holds data going to the module.

8200-M554-O1 x2XX-EIP
Page 8
CONFIGURE THE PLC USING RSLogix5000, CONT.
Input:
The weight data begins at Data[0] and uses the next four bytes to produce a floating point
program tag.
Float = (Data[0], Data[1], Data[2], Data[3])
Weight
Weight Status
PWC Status
CMD 0 return
when complete
CMD 1 return
when complete
CMD 0
CMD 1
N/A
Float Byte 0
Float Byte 2
Float Byte 3
Float Byte 1
Table des matières
Autres manuels Cardinal Carte réseau
Manuels Carte réseau populaires d'autres marques

3Com
3Com EtherLink 3C509B Manuel utilisateur

TRENDnet
TRENDnet TEG-PCITX Manuel utilisateur

Cisco
Cisco MC16E Manuel utilisateur

Delta Electronics
Delta Electronics Braking Modules VFDB Series Manuel utilisateur

TwinMOS
TwinMOS Booming Manuel utilisateur

Dialogic
Dialogic Media Board DM/V1200BTEPEQ Manuel utilisateur

Buffalo
Buffalo AirStation WLI-PCM-L11GP Manuel utilisateur

National Instruments
National Instruments NI 9234 Manuel utilisateur

Hama
Hama 49276 Manuel utilisateur

Linksys
Linksys WCF54G - Wireless-G Compact Flash Card Manuel d'utilisation

Compaq
Compaq Wireless LAN 100 Manuel utilisateur

Bose
Bose PowerMatch Dante Manuel utilisateur