BROMECH ATP ASP Manuel utilisateur

ATP_ASP
Price Computing Scales


ATP_ASP Price Computing Scales Operation Manual Rev:Y2,August,2020
CONTENTS
1.PRECAUTIONS............................................................................................................ - 1 -
2. INTRODUCTION......................................................................................................... - 2 -
3. INSTALLATION.......................................................................................................... - 2 -
3.1Unpacking......................................................................................................... - 2 -
3.2 Installation....................................................................................................... - 3 -
3.3 Leveling............................................................................................................ - 3 -
3.4 Power Connection........................................................................................... - 3 -
3.5 Rechargeable battery operation.....................................................................- 3 -
3.5.1 Charging Battery...................................................................................- 4 -
3.5.2 Battery maintenance............................................................................ - 4 -
4. DISPLAY&KEYS FUNTION.........................................................................................- 5 -
5. OPERATION................................................................................................................- 6 -
1. Power ON/OFF...................................................................................................- 6 -
2. Zero..................................................................................................................... - 6 -
3. Tare..................................................................................................................... - 6 -
4. Weighing Units...................................................................................................- 6 -
5. Unit Price Setting............................................................................................... - 7 -
6. PLU Setting......................................................................................................... - 7 -
7. Automatic Unit Price Clear................................................................................- 8 -
8. Printing Operation.............................................................................................- 8 -
9.Back light Setting................................................................................................ - 9 -
6. CALIBRATION.......................................................................................................... - 10 -


- 1 -
1.PRECAUTIONS
WARNING
DISCONNECT ALL POWER TO THIS UNIT BEFORE
INSTALLING, CLEANING, OR SERVICING. FAILURE
TO DO SO COULD RESULT IN BODILY HARM OR
DAMAGE THE UNIT.
CAUTION
Permit only qualified persons to service the instrument
Before connecting or disconnecting any components, remove the
power.
Failure to observe these precautions bodily harm or damage to or
destruction of the equipment.
The weighing scale is a precision electronic instrument, handle it carefully.
Do not install the scale in direct sunlight.
Verify the local voltage and receptacle type are correct for the scale.
Only use original adaptor, other could cause damage to the scale.
Pluggable equipment must be installed near an easily accessible socket outlet.
Avoid unstable power sources. Do not use near large users of electricity such
as welding equipment or large motors.
Avoid sudden temperature changes, vibration, wind and water.
Avoid heavy RF noise.
Keep the scale clean

Rev:Y2,August,2020 ATP_ASP Price Computing Scales Operation Manual
- 2 -
2. INTRODUCTION
ZTP /ZSP series of economic price computing scales are very compact,
reliable , high accuracy and much stable.
It use15mm LCD display with white LED back light
Weighing unit conversion
20 membrane keyboard
10 indirect PLU and 2 direct PLU ,it can store 12 unit price values
Auto unit price clear operation
Battery provide up to 60 hours of continues use (without backlight)
Capacity 6 kg (12lb) to 30 kg (60lb)
Standard RS-232 interface can be connect to computer , ECR or printer
3. INSTALLATION
3.1Unpacking
Carefully take the scale out of its package, make it sure its not damaged and all
accessories are included.
Remove the scale from the carton.
Remove the protective covering. Store the packaging and to use if you need
to transport the scale later.
Inspect the scale and terminal for damage.
Make sure all components are included
Accessories,
1. Scale
2. Adaptor
3. Pan
4. Product manual

ATP_ASP Price Computing Scales Operation Manual Rev:Y2,August,2020
- 3 -
3.2 Installation
Remove transport lock from bottom of the scale base
Place the scale on a level surface
Install the stainless steel pan to the four hole on top of housing
3.3 Leveling
The scale is equipped with a level indicator located back side of scale
Use the adjustable leveling feet located on the bottom of the scale until the
bubble appears in the center of the scale.
3.4 Power Connection
Connect the adaptor pin in to the adaptor jack.
Adaptor jack is locating below the right side of the scale.
Adaptor connects into your AC power socket. Plugable equipment must be
installed near an easily accessible socket outlet with a protective ground/
earth contact.
3.5 Rechargeable battery operation
Note: Please charge the battery before using the scale for the first time.
The symbol above on BATT appears. scale of the weight display indicates that
the battery is getting low. it’s time to charge the battery with the AC power. If
scale goes on being used without proper charging, <BAT-LOW> words will
flicker on the display.
Level bubble
AC Adapter jack

Rev:Y2,August,2020 ATP_ASP Price Computing Scales Operation Manual
- 4 -
Approximately 30 minutes of instrument usage are left; afterwards it will
shut off automatically.
Please use the supplied battery charger for charging the battery
immediately,or scale cannot be used.
3.5.1 Charging Battery
To charge the battery insert the adaptor pin to jack, jack is locating below the
scale. Adaptor simply plug into the mains power. The scale no needs to be
turned on.
The battery should be charged for 12 hours for full capacity.
Left side of the Total Price display there is an LED to indicate the status of
battery charging. When the scale is plugged into the mains power the
internal battery will be recharged. If the LED is green, the battery has a full
charge.
If it is red, the battery is being charged.
Do not use any other type of power adaptor than the one supplied with the
scale.
Verify that the AC power socket outlet is properly protected.
3.5.2 Battery maintenance
Recharge battery should be changed in every three months when not in use.
If the scale is not used for an extended period of time,remove the battery from
the battery compartment to avoid leakage.
Store the battery in a sealed bag or box in a dry, temperate environment.

ATP_ASP Price Computing Scales Operation Manual Rev:Y2,August,2020
- 5 -
4. DISPLAY&KEYS FUNTION
Indication
Keyboard
Keys
Function
Numeric Keys, enter unit price / PLU;
In setting mode ,press numeric keys to enter
parameters setting
Clear incorrect entries and error conditions
Set unit price in fix mode,press the key to input
double zero;
Set unit price in float mode,press the key to input
decimal point
Returns the display to zero.
In setting mode,to escape from the menu
Subtracts the tare values,
Hold the key to enter parameter settings.
Enter to auto clear mode
Used to store or recall unit price,
In setting mode,used to scroll down the menu
Used to print out the print format
to
Used to store or recall direct PLU information
Used to change unit (kg/lb)
Zero
Zeroing Display
Stable
Stable Display
Net
Net Weight Display
BATT.
Low Battery
kg /lb
Current Weighing units
Charge
Charging Indication
SAVE
Save Indicator

Rev:Y2,August,2020 ATP_ASP Price Computing Scales Operation Manual
- 6 -
5. OPERATION
Initial Start-up
Warm-up time of 15 minutes stabilizes the measured values after switching on.
1. Power ON/OFF
Power switch is located below the right side of the scale.
Turn the scale ON; press the switch forward and hold. The scale will show the
capacity and enter a self-test mode and follow to enter the weighing mode.
Turn the scale OFF, press the switch forward once.
2. Zero
Environmental conditions can lead to the balance exactly zero in spite
of the pan not taking any strain. However, you can set the display of
your balance to zero any time by pressing key and therefore
ensure that the weighing starts at zero.
3. Tare
The weight of any container can be tared by pressing button so that
with subsequent weighing the net weight of the object being weighed is
always displayed.
1 Load weight on the pan.
2 Press key. Zero is displayed, and tare is subtracted.
3 Remove weight from the platform. Tared weight is displayed. It can set only
one tare value. It can display with a minus value.
4Press key. Zero is displayed, tare weight is cleared.
4. Weighing Units
Press key in the weighing mode to change the weighing units kg / lb.