Bristan DOC M Series Guide d'installation

Please keep this booklet for future
reference.
Installer, when you have read these
instructions please ensure you leave them
with the user.
Installation Overview
DOC M Packs
Models covered:
DOCM-T3 B, DOCM-T3 W

2
Contents
Thank you for choosing Bristan, the UK’s leading taps and showers expert.
We have designed this product with your enjoyment and safety in mind. To ensure that it
works to its full potential, it needs to be fitted correctly. These fitting instructions have
been created to give you all of the information you need and, if you need any further
help, please do not hesitate to contact us using the number at the bottom of this page.
Important Safety Information................................................... 3
General Guidelines................................................................... 4
Installation Plan ....................................................................... 5
Installation ............................................................................... 6-13
WC Pan ............................................................................... 6-9
Basin ................................................................................... 10
Solo T3 Tap.......................................................................... 11-13
Installation ................................................................. 11-12
Operation.................................................................... 12
Grab Rails ........................................................................... 13
General Maintenance ............................................................... 14
Guarantee ................................................................................. 14
Notes......................................................................................... 15
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.

3
Important Safety Information
• Please read these instructions thoroughly and retain for future use.
• All products manufactured and supplied by Bristan are safe provided they are
correctly installed, used and receive regular maintenance in accordance with these
instructions.
• This product needs to be installed in accordance with, and meet the requirements of
the Water Supply (Water Fittings) Regulations 1999 and Scottish Byelaws 2004.
• Remove all packaging and check the fitting for damage before starting installation.
• Warning: Before starting any installation please consider the following: Before
drilling into walls, check that there are no hidden electrical wires, cables or water
supply pipes. This can be checked with the aid of an electronic detector.
• If power tools are used do not forget to: - Wear eye protection
- Unplug equipment after use
• Important: Remember to turn off the mains water supply before connecting to any
existing pipe work. Fitting isolating valves to the inlet feeds is recommended for
ease of maintenance.
• Warning: Before installing the new fittings it is essential that you thoroughly flush
through any new and existing pipework in order to remove any remaining swarf,
solder, etc. Failure to carry out this procedure could cause problems or damage to
the workings of the fitting.
• Take care when handling ‘flexible connecting pipes’ supplied with certain taps. Do
not bend, twist or crush them. Only tighten the pipes by hand.
• This product must not be modified in any way as this will invalidate the guarantee.
• If you are in any doubt about your ability to install this product safely you must
employ the services of a competent person, for example, a qualified plumber with
experience in installing products of this nature.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.

4
General Guidelines
This product has been tested to the Water Regulations Advisory Scheme (WRAS) and
satisfies the requirements of the Water Supply (Water Fittings) Regulations 1999 and
current bylaws. For full Installation Requirements & Notes (IRN) please visit
www.wras.co.uk/directory.
Designed to comply with BS EN 200 for combination taps to be used within systems
designed to BS 6700.
BS 6700 recommends the temperature of stored water should never exceed 65°C.
A stored water temperature of 60°C is considered sufficient to meet all normal
requirements and will minimise the build up of lime scale in hard water areas.
If the fitting is installed at low pressure (tank fed), then the minimum distance from the
highest installed position of the outlet to the underside of the cold tank should be at
least 2 metres to ensure adequate performance.
The tap supplied with this product should be installed in compliance with the Water
Regulations. Where the supplies are unbalanced, i.e. Hot water from cylinder tank / cold
from the mains, approved check valves must be fitted in the supply pipes.
For further details contact your Local Water Authority.
When installing this product, it is expected that the first fix pipework will have been
installed and the general design and accomodation will already be known.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.

5
Installation Plan
Dimensions are nominal and in millimetres.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
850 Min 600
Max 700
250 B
82.5
B
A A
CC
Min 2200
400
500
500
320150
1000
Min 1500
Hinged
Support Rail
Pull Rail Fixed
To Door
Min 140
Max 160
Standard DOC M Pack
Note: Please adhere to all standard height measurements shown in the following diagram.

6
Installation - WC Pan
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
12
3 4
Position the cistern on its back. Assemble
and insert the flush mechansim.
Insert fixing bolts through the holes in the
cistern, using the rubber and large metal
washer.
Place the large rubber gasket into the
flush entrance of the pan.
Lift the cistern onto the pan so the
connecting bolt fit through the holes.

7
Installation - WC Pan
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
56
7
Fit the washers and wing nuts to the
underside of the cistern and tighten the
nuts.
Insert a pan connector into the waste
pipe.
Ensure the cistern is level by placing spirit
level along the back against the wall.
Mark off the fixing holes through the back
of the cistern.
8
Draw a line around the base of the pan to
clearly mark the position and mark the
position of the screw holes.

8
Installation - WC Pan
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
910
11
Drill fixing holes for cisten/pan through
the marks on the wall/floor. Use wall
plugs according to wall/ floor surface.
Fix the cistern to the wall with screws and
washers (not supplied). Ensure the cistern
is not pulled backwards, as the seal with
the pan might broke.
Return the pan to the desired location,
make the plumbing connections and
ensure that they are water tight. Ensure
the pipework is flushed prior to
connecting the cistern.
12
Insert screws at the base of the toilet to
fix the pan to the floor using the washers
provided. Do not overtighten.

9
Installation - WC Pan
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Open/On
position
Close/Off
position
13
Connect the cold water supply. Turn on
water supply at the isolation valve and
check for leaks.
Fit the lever and place the lid onto the
cistern, use cistern blanking plug to cover
unuse hole.
14

10
Installation - Basin
• Consider and plan the design and accomodation of your DOC-M suite around the
layout of your waste system and suitablity of future access.
• Use suitable wall fixings for your wall construction.
• Do not overtighten wall fixings, taps or wastes onto ceramic surfaces.
• Use a non-permanent marker or pencil for marking.
Standard Pedestal Installation
1. Decide on the final position of the basin.
Install suitable bottons onto the wall cavity to
support the weight of the basin if required.
2. Mark the position of the basin and the
centre of the basin.
3. Mark the position of the fixing holes.
4. Drill holes using suitable drill and insert
wall fixings.
5. Use suitable screws to secure basin to the
wall.
6. Fit the basin mixer and use blanking plug
to cover unused holes in a basin.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
450
115
60
190
Ce manuel convient aux modèles suivants
2
Table des matières
Manuels Aide à la salle de bain populaires d'autres marques

Pressalit Care
Pressalit Care R2040 Manuel utilisateur

Invacare
Invacare 9630E Styxo Instructions de montage

Leckey
Leckey firefly splashy BIG Manuel utilisateur

NRS Healthcare
NRS Healthcare H85350 Manuel utilisateur

WENKO
WENKO 23285100 Manuel utilisateur

Dietz SmartCare
Dietz SmartCare TAYO Manuel utilisateur