BPC Airflow DV145 Adroit Manuel utilisateur

Instruction Manual
80000484 - Issue 1 04/16
Valid from 01/05/16
DV145 Adroit
90000580
90000580EPH
90000581
90000581EPH
DV110 Adroit
90000578
90000578EPH
90000579
90000579EPH
DV96 Adroit
90000576
90000576EPH
90000577
90000577EPH


1. INTRODUCTION
• The main parts of the ventilation unit
• System description
• General safety Instructions, guarantee and liability
• Control panel buttons
• Starting up and shutting down the unit
2. DEPLOYMENT WIZARD
• Basic settings (setting the language, time and date)
• Expert settings (setting the password and access rights,
parental controls, fan settings, profile settings)
3. USING THE UNIT
• Ventilation profiles
• Temperatures and Sensors
• Settings (filter, display settings, time and date, week clock, switching the
unit off)
4. MAINTENANCE
• Filters
• Heat recovery cell
• Fans
• Condensing water
• Troubleshooting
5. TECHNICAL SPECIFICATIONS
• Technical data, supply/extract air volumes, fan curves, sound values,
main components, measurement points, dimensions and duct outlets
• Internal electrical connection
• External electrical connection
• Heating/cooling radiator operation chart
6. MOUNTING
• Wall mounting
• Measuring tubes
• Ceiling mounting
• Floor mounting
• Condensing water
7. CERTIFICATE OF CONFORMITY
8. EXPLODED VIEW AND PARTS LIST
9. USER LEVEL DIAGRAMS
CONTENTS
4
10
19
38
44
56
60
61
64
10..COMMISSIONING THE SYSTEM
11..WARRANTY
66
67


5
INTRODUCTION
SYSTEM DESCRIPTION

6
DIFFERENCES BETWEEN THE UNITS
•Power
•Size
•DV96 can be equipped with an optional electric post heater.
DV110 and DV145 can be equipped with either one or two
optional electric post heaters.
•Weight
•In the model DV96, there is a sealing tape at the bottom of the
heat recovery cell. In other models, there is a separate sealing
bar under the heat recovery cell.
•Standard delivery options vary from country to country.
•The available options vary from country to country.
Mounting options:
•Models DV96 and DV110 can be mounted either on the wall,
or on the ceiling by using the optional mounting plate. These
models can also be mounted on the floor via a installer
prepared stand.
•Model DV145 can be mounted either on the wall, or on the
floor by using a floor rack (optional). This model cannot be
mounted on the ceiling.
GENERAL SAFETY INSTRUCTIONS
For safe and proper handling, it is necessary to know the basic
safety regulations and the intended usage of the ventilation
system. Read this manual before operating the ventilation unit.
Keep this manual for later use. In case of loss, you can download
the manual from our website.
This user manual contains all important tips for operating the
system safely. This user manual must be observed by all
persons who operate and maintain the ventilation system.
Furthermore, observe all local accident prevention regulations.
INTENDED USE
All ventilation units are designed to take care of appropriate
and continuous ventilation, in such a way that people and
structures will remain healthy.
GUARANTEE AND LIABILITY
Demands on guarantee and liability are excluded if they
are caused by the following reasons:
•Unintended use of the ventilation system and the control unit
• Improper mounting, initial operation and operation
• Operating the ventilation system with a defective safety
system
• Ignoring advice for transportation, mounting, operation and
maintenance
•Unauthorized structural alteration and changes of the
programming
•Disasters due to extraneous elements and force majeure
INTRODUCTION

7
Change profile button. This button allows you to change
the ventilation profile of the device.
Profile Information button. This button allows you to view
the currently active profile information.
Temperature button. Pressing this button displays
information on temperatures and sensors.
Settings button. Press this button to open the settings.
Back button. Pressing this button takes you backwards in
the menu.
Left arrow button. Pressing this button takes you to the
left in the menu.
Right arrow button. Pressing this button takes you to the
right in the menu.
OK button. Press this button to accept the selected
option.
Select button. Press this button to select an option from
the list.
Edit button. Press this button to edit settings.
Plus button. Press this button to:
•Increase the value of the setting.
•Move to the next menu item.
•Move from a one-day view to a week view in the
temperature, humidity and carbon dioxide graphs.
Minus button. Press this button to:
•Reduce the value of the setting.
•Return to the previous menu item.
•Move from a week view to a one-day view in the
temperature, humidity and carbon dioxide graphs.
Up arrow button. Pressing this button takes you upwards
in the menu.
Down arrow button. Pressing this button takes you
downwards in the menu.
Statistics button. This button opens the temperature,
humidity and carbon dioxide graphs (1 day / week).
These icons indicate the settings hierarchy level.
This icon indicates that the feature is disabled at your user
level. The parental controls lock code is 1001.
BUTTON DESCRIPTION
INSTALLATION
Installation and setup should only be carried out by qualified
experts. Electrical installations and connections must only be
carried out by electricians, and according to the local regulations.
CONTROL PANEL BUTTONS
INTRODUCTION

8
INTRODUCTION
INTRODUCTION
Ventilation has to be constant for the indoor air to stay healthy for
the dwellers and the structures of the dwelling. Even for longer
holidays, it is not advisable to stop the ventilation, because the
indoor air will become stuffy and, during the heating season, the
indoor air humidity may condense in the ventilation ductwork and
structures, causing moisture damage.
You can control and automate the ventilation unit operation in the
following ways:
•By using a control panel installed in the building
•Through the Home local network connection and the Web
interface
• Through the Adroit Cloud Service and the Web interface
• Through a remote monitoring service or building automation
by using voltage signals or Modbus messages
The required ventilation may also be adjusted automatically with
the optional carbon dioxide and humidity sensors. In this case,
ventilation remains optimal even if the dwelling is unoccupied.
By using the week clock, you can create just the right ventilation for
your individual lifestyle.
WARNING
The unit is not intended for use by children (under 8 years) or by
persons with reduced sensory, physical, or mental capabilities, or
lack of knowledge and experience, that limit the safe operation of
the unit.
These people can use the product under the supervision of a
person responsible for their safety, or as directed.
TIP
The Adroit Digital Controller panel automatically switches to
sleep mode when the pre-set sleep time has elapsed. If you want
to wake up the Adroit Digital Controller panel, press any button
on the control panel.

9
The ventilation specialist has made the ventilation system with
basic and expert settings, based on the ventilation plan. The
basic settings are:
If you are satisfied with the basic settings made by the installer,
do not make changes to them.
STARTING THE UNIT
If you are starting the ventilation unit for the first time, or after
any maintenance procedure, when the unit starts up, the
diagnostic display will appear for a few seconds, until the At home
profile main screen is opened.
If the unit is switched off from the control panel, you can start the
ventilation unit by pressing any button on the control panel.
NOTE
The first launch of the unit may take a while, as the control panel
will format its software and verify that it has the latest software
version.
SWITCHING THE UNIT OFF
If you want to switch off the ventilation unit, proceed as follows:
1. Select Settings > Turn unit OFF.
2. Press the OK button.
3. The system asks for confirmation.
4. Press the OK button.
5. The ventilation unit is now switched
off.
INTRODUCTION
•User interface language.
•Time and date.
The expert settings are:
•System administrator password. The installer has given
you the system administrator password.
•Possible parental controls.
•Fan settings.
•User profile settings, such as the temperature.

10
BASIC SETTINGS
DEPLOYMENT WIZARD
1. Start the ventilation device.
2. Press the OK button.
3. The deployment wizard is launched.
SELECTING THE LANGUAGE
Select the user interface language as follows:
1. Use the arrow buttons to select the language you want, for
example, English:
2. Press the OK button.
3. The selected language is now English.
SET THE TIME
When the deployment wizard prompts you to set the date and
time, the Time and date screen is opened first:
1. Use the Plus and Minus buttons to set the hours.
2. Press the Right arrow button.
3. Use the Plus and Minus buttons to set the minutes.
4. The time is now set.
5. Proceed to the next phase by pressing the Right arrow
button.
SET THE 24 OR 12 HOUR CLOCK
By default, the system uses a 24 hour clock.
If you want to use the 24 hour clock, proceed to the next step by
pressing the Arrow right button.
If you want to use the 12 hour clock, proceed as follows:
1. Press the Minus button. The 24-Hour Time setting value is
changed to Off.
2. Proceed to the next phase by pressing the Right arrow
button.