Bogen NYQUIST NQ-GA10P Manuel utilisateur

VoIP Intercom Module
Configuration Guide
NQ-GA10P, NQ-GA10PV
© 2021 Bogen Communications, Inc.
All rights reserved.
740-00068B
211116

i
Contents
Configuring the Nyquist VoIP Intercom Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Using the Dashboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Standalone Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Updating Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Network Settings Tab Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Configuration Settings Tab Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Standalone Operation Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Accessing Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

ii
List of Figures
Figure 1. Nyquist Appliance Login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Figure 2. Intercom Module Dashboard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Figure 3. Firmware Update Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Figure 4. Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Figure 5. Appliance Configuration Settings (Standalone enabled) . . . . . . . . . . . . . . . . .11
Figure 6. Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

iii
List of Tables
Table 1, Appliance Dashboard Fields. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Table 2, Appliance Dashboard Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Table 3, Firmware Update settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 4, Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 5, Configuration Settings (Standalone disabled) . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 6, Configuration Settings (Standalone enabled). . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 7, Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

1
Configuring the Nyquist VoIP Intercom
Module
Bogen’s plenum-rated Nyquist Voice over Internet Protocol (VoIP) intercom modules
transform any low-impedance analog speaker into a full-featured Power-over-Ethernet
(PoE) IP speaker. The modules use the latest technology to deliver superior audio quality,
making them perfect for IP paging and audio distribution. The built-in talkback capability
allows these modules to be used in VoIP intercom applications.
These 10-watt single-channel intercom modules are available with (NQ-GA10PV) or with-
out (NQ-GA10P) an HDMI video output, depending upon the application needs. They
also offer a CAN bus interface to work with the NQ-E7020 Digital Call Switch and a Form-
C relay for controlling third- party devices. Additionally, when paired with Bogen’s
ANS500M microphone module (optional), these intercom modules can be turned into an
ambient noise sensor to help maintain paging and background music intelligibility in
high-noise environments.
If an HDMI video device is attached, this device can display messages and images sent by
a Nyquist server, as well as a digital or analog clock. These messages can be used for
scheduled announcements, emergency instructions, automatically triggered messages,
simple ad-hoc messages, or many other purposes. If a Nyquist server is not present, the
device will display an analog clock and compatibility information about supported reso-
lutions. For further information on displaying and scheduling messages, see the “Manag-
ing GA10PV Display Messages” section of the Nyquist System Administrator Guide.
The Nyquist server or system controller can automatically discover and configure the
VoIP intercom module, but you can also manage the device, and manually configure
some settings, through the VoIP Intercom Module’s web-based user interface (web UI).
A short press of the appliance’s Reset button reboots the device. If you press the Reset
button for 10 seconds, the appliance returns to the factory default configuration settings.
Returning to the default configuration settings does not change the appliance’s firmware.
The following sections describe settings and configurations that can be applied to this device
which are not controlled by the Nyquist server. For information about using Nyquist’s auto-
matic configuration process, refer to the Nyquist System Administrator Guide.
To access the appliance’s UI:
1Access the appliance’s web UI by doing one of the following:
a) On your web browser, enter the IP address for the appliance as the URL.
b) From the Nyquist web UI navigation bar, select Stations, select Stations Status,
navigate to the device that you want to configure, and then select the Link icon.
Note: Do not use third-party Chrome browser extensions with the Nyquist user interface.

2
2At the Nyquist Appliance - Login page, enter username and password, and then select
Login.
The default username is admin; the default password is bogen.
The dashboard for the selected appliance appears.
Figure 1. Nyquist Appliance Login
Figure 2. Intercom Module Dashboard

3
Using the Dashboard
The dashboard displays the following fields:
The following buttons are available at the top of all pages in the application.
Table 1. Appliance Dashboard Fields
Device Type Identifies the model of this device.
Serial Number Identifies the serial number for the device.
MAC Address Specifies the Media Access Control (MAC) address,
which is a unique identifier assigned to network inter-
faces for communications on the physical network seg-
ment.
Firmware Version Provides the firmware version installed on the device.
Standalone Operation Enables or disables Standalone mode.
Table 2. Appliance Dashboard Buttons
Dashboard Displays the dashboard.
Configuration Settings Accesses the Configuration Settings page where you can
view and set various options. If Standalone Operation is
not enabled, you can also receive configuration settings
from a Nyquist server.
Network Settings Accesses the Network Settings page where you can view
and set network settings, such as the static IP address.
Firmware Update Accesses the Firmware Update page where you can view
the current Nyquist version, update firmware to a new
version, restore the configuration to factory defaults,
and reboot the appliance.
Logs Accesses log files, which record either events or mes-
sages that occur when software runs and are used when
troubleshooting the appliance.
Help Accesses the appliance’s online help.
Manual Displays this appliance’s configuration guide.
Logout Logs out of the appliance’s dashboard.

4
Standalone Operation
This device can run in Standalone Operation mode, where it will not interact with a
Nyquist server (e.g., E7000 or C4000). This means the device will not:
• Fetch device configuration from Nyquist server
• Register with Nyquist server (via SIP)
• Store backup information to Nyquist server
• Allow access to Nyquist server-based NTP
Standalone Operation mode is ideal for scenarios that do not require the full functionality
provided by an integrated system, such as the Bogen C4000 or E7000 Series, but has the
ability to provide paging, multi-channel audio processing, and a SIP endpoint for a PBX/
VoIP phone system. It can be used to play music, audio, paging, and related functions.
Updating Firmware
When you select Firmware Update from the appliance’s web UI, the Firmware Update
page appears. From this page you can determine which Nyquist firmware version the
appliance is using and if an update is available. You can also load a firmware release,
install the loaded firmware, restore the configuration to factory defaults, and reboot the
appliance.
Note: A Nyquist appliance connected to the Nyquist network receives a configuration
file from the Nyquist server that includes the latest firmware available from the server.
If the firmware is different from the one installed on the appliance, an automatic firm-
ware update occurs unless the Firmware parameter for the station is left blank. Refer to
the Nyquist System Administrator Guide for more information.

5
To use the Firmware Update page:
1On the appliance web UI’s main page, select Firmware Update to view or update the
firmware version.
2If the device is in Standalone mode, selecting the Check for Updates button checks
the Bogen website for the latest firmware version available. If a version newer than
the one currently installed is found, it is downloaded to the appliance.
3If you already have a firmware file you would like to install to the appliance, select
Upload Firmware to upload the firmware file from your computer to the appliance. A
popup screen appears that allows you to select the file that you want to upload. You
can navigate to the file’s location. After you select the file, select Upload.
4The page displays the uploaded firmware version (“New Nyquist Version”) and an
Update Firmware button appears. Select this button if you want to update the appli-
ance’s firmware to the uploaded version.
5If you want to return your appliance to its original factory configuration, select
Restore Factory Settings.
6Select Reboot Appliance to restart your appliance.
Figure 3. Firmware Update Page

6
Network Settings Tab Parameters
Network settings can be configured dynamically by the Nyquist server or manually by
using the appliance’s web UI.
To manually configure network settings:
1On the appliance web UI’s main page, select Network Settings.
Table 3. Firmware Update settings
Current Nyquist Version Shows the version of the appliance’s currently
installed firmware.
New Nyquist Version Shows the version of the firmware that has been
loaded, though not installed, onto the appliance.
Update Firmware Available only when a new firmware version has
been loaded onto the appliance (as specified in
New Nyquist Version).
Installs the loaded firmware. A reboot may be
required after installation.
Upload Firmware Prompts the user to specify a firmware file, which
will then be loaded (though not installed) onto the
appliance.
Note: To obtain the firmware file for a specific ver-
sion, please contact Bogen Customer Service.
Check for Updates Available only when the appliance is configured
for Standalone mode.
Checks the Bogen website for the latest firmware
version available and, if it finds a version newer
than what is currently installed, downloads it to
the appliance.
Restore Factory Settings Returns the appliance to its original factory con-
figuration.
Note: This does not install the original appliance
firmware. The firmware will not be changed.
Reboot Appliance Restarts the appliance.
Autres manuels pour NYQUIST NQ-GA10P
2
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Bogen Système d'interphone

Bogen
Bogen ADP1 Manuel utilisateur

Bogen
Bogen Multi-Graphic SI35A Manuel utilisateur

Bogen
Bogen IE-4A Manuel utilisateur

Bogen
Bogen NQ-EDP01 Manuel utilisateur

Bogen
Bogen PI35A Manuel utilisateur

Bogen
Bogen PI35A Mode d'emploi

Bogen
Bogen CM-206M Manuel utilisateur

Bogen
Bogen TQ6-A Manuel utilisateur

Bogen
Bogen PI35A Manuel utilisateur

Bogen
Bogen ADP1 Mode d’emploi