The PRO-100Q/200Q are quad photoelectric detectors designed to activate an alarm relay upon the detection of
Intruder through 4 pulsed infrared beams.
For stable operation, the PRO-100Q/200Q are equipped with the following features.
■ High power infrared
The active infrared transmission is exceptionally strong with a maximum arrival distance ten times greater than
the specified protection distance.
■ Four frequency selections
4 separate choices of frequency avoids cross-talk in stacked or long linear installations.
■ Beam transmission strength selection
2 levels of beam transmission strength which can be set to suit the protection distance.
■ Auto-gain lock
Optimal sensitivity gain is automatically set at any coverage distance up to the maximum protection distance.
(Audible tone indicates setting is completed)
■ Environmental module
Environmental trouble signal is sent when beam reception level is reduced below an acceptable level.
■ Programmed AGC function
Sensitivity is automatically increased in bad weather to contend with fog, rain, of frost.
■ Alarm memory indicator
Alarm memory LED located on Receiver can be manually reset (at sensor) or remotely controlled via panel.
■ Audible signal for alignment
An alignment tone aids in quick set-up of beams for electrical measurement of alignment
■ Retransmitting function
The advantage is elimination of wiring from a detector or switch, back to the control panel.
■ Other features
Monitor output, Level LED , Response time changeover, Tamper output.
WARNING ! Indicate that incorrect operation causes significant danger of accident resulting in death or serious
Injury to the user.
CAUTION ! Indicate that incorrect operation causes possibility of injury to the user of damage to the unit.
Read the following prior to installing, wiring and regular maintenance.
CAUTION ! DO NOT INSTALL THE UNIT
① where trees, plants, of falling leaves will block the beams.
② where intense source of light, sunlight will be reflected directly into the receiver optics.
A foreign light incoming within ±3° angle of each receiver axis may cause false alarms.
③ on movable surfaces.
④ where subject to foul water or sea spray.
⑤ where over the max range on each model.
⑥ where subject to strong electrical noise or RFI
⑦ where subject to strong vibration.
⑧ where subject to corrosive or explosive gas.
AVOID
① external temperature and humidity.
② magnets or any magnetized material.
③ running power and output wires near voltage power sources.
IMPORTANT
① Face upper/lower optical modules on the transmitter and receiver towards each other.
② Be sure of the beam in alignment optical modules can be adjusted within ±90° horizontally and ±3° vertically.
WARNING !
① Do not perform installation and wiring when it thunders.
② Do not supply power until all wiring is completed.
③ Keep power between 10 V ~ 28 VDC anytime.
④ Do not disassemble or modify the unit.