Blue connect Manuel utilisateur

USER MANUAL

2
Blue Connect
Blue Fit50 » USER MANUAL
Thanks for choosing Blue Connect.
www.blueconnect.io
Introduction
A. Overview
Blue Connect continuously measures the key parameters of your swimming pool (temperature, pH,
chlorine, conductivity). It also informs you of the external temperature and weather based on your
geolocation. The results of this analysis are then communicated to you via notications on the
“Blue Connect“ app (available on smartphone and tablet, compatible with Android™ and iOS). If the
device detects that one of the parameters is incorrect, an alert informs you of this status and provides
you with the instructions to follow to regulate and stabilize this parameter in order to maintain a
healthy and balanced water.
Blue Connect measures:
» Water temperature (°C, °F): An elevated temperature reduces the efficiency of the chlorine and
promotes the development of microorganisms.
» pH (hydrogen potential): this quantity measures the acidic or basic character of a medium. pH
contributes to the effectiveness of the disinfectant.
» ORP/REDOX (measurement of active chlorine in mV): the oxidation-reduction potential, or redox
potential, measures the oxidizing or reducing power of one substance compared to another. It
provides information on the disinfecting power of water.
» Conductivity1 (μS): Measurement of the concentration of inorganic salts in the water by the ability
of the latter to conduct electricity.
B. Precautions for use
» Do not use Blue Connect for anything other than water analysis.
» Blue Connect is not a toy. Avoid shocks as they may damage it.
» Keep Blue Connect out of reach of children when handling it (e.g. calibration and standby) due to
the use of chemicals. Store calibration products out of reach of children.
» Do not open the top part of the device (except when replacing the battery). Follow carefully the
battery replacement instructions. Damage caused by liquids is not covered by the warranty.
» Do not open the bottom part of the device containing the probe (except when replacing the
probe). Follow carefully the probe replacement instructions. Damage caused by liquids is not
covered by the warranty.
» Make sure not to leave the probe out of the water without the storage cap filled with KCl (saturated
potassium chloride), pH4 or, as a last resort, pool water.
» Do not use demineralized water in the storage cap.
» Make sure the top part of the unit is out of the water to allow the communication system to work.
» Do not leave Blue Connect in water with a temperature below 5°C or above 50°C.
» Keep the Blue Connect serial number and key2.
» Store Blue Connect sheltered from frost.
1For salt pools, salinity (more precisely the total salt content) is measured on the conductivity basis. Salinity (g/L) is used to
evaluate the amount of salts in the water.
2On the back of the quick start guide and on Blue Connect’s storage cap.

3
Blue Connect
Blue Fit50 » USER MANUAL
Description of the equipement
Blue Connect analyser: Delivered secured on the storage cap to
protect the probe during transportation. The probe is immersed in KCI
(saturated potassium chloride), which assures its protection.
The storage cap: Used to transport the probe out of the water or to
keep the sensors immersed during an extended storage (in winter
for example).
The usage cap: Must always be mounted on the device before placing
it in water. It protects the sensors from any damage.
Cord: Allows to x the device to a point of attachment.
Quick start guide: Helps you with the device start-up .

4
Blue Connect
Blue Fit50 » USER MANUAL
App installation
Activate the Internet (Wi-Fi or 4G) and Bluetooth® on your smartphone or tablet.
NB: Stay close to your device throughout the whole Blue Connect activation process.
Download the free “Blue Connect” app on App Store® and Google Play™.
Authorize notifications to benefit from the alerts.
Login to “Blue Connect”:
» via Facebook®.
» via Twitter®.
» via your email address.
Create your swimming-pool: enter your swimming pool’s characteristics.
NB: You can view or modify the characteristics of your swimming pool at any time in
“Settings” » “Pool”.
NB: To add a second swimming pool in the app, press the name of the active swimming pool and
select “Add a pool”.
The application is divided in four main sections3:
Dashboard: Informs you of Blue Connect’s status, the water temperature, the local weather
and the quality of your pool water.
Table of values: Informs you precisely of the values measured by Blue Connect, trends and
ideal values.
Maintenance guide: Advises you on the operations to perform to maintain the quality of the
water in your pool.
Settings: Allows you to configure the settings for your pool and Blue devices, as well as have
access to help and technical support.
3.
5.
1.
2.
4.
3The app is subject to continual improvements and changes.

5
Blue Connect
Blue Fit50 » USER MANUAL
Blue Connect installation
A. How to start up Blue Connect?
In the app, in “Settings” » “Blue Connect”, press “Add” and insert the code (key) and the
three last digits of the serial number (SN), which can both be found on the back of the start
guide or on the storage cap of the device.
To start the device, you must activate it. The top of the device has a wave shape. Place the
trough of the wave towards yourself and shake it sharply. You will hear two beeps, meaning
that the initial activation was successful.
Press “ok” to finalize the activation process. The device is now linked to your account and
permanently linked to Sigfox®4network.
Place Blue Connect upright on the storage cap and unscrew it.
Empty the storage cap, rinse in clear water and store it.
1.
2.
3.
4.
5.
4Sigfox® is a telecommunications network specialised in the Internet of Things. It is a cellular network that does not interfere
with domestic Wi-Fi. You can check if your swimming pool is covered by the Sigfox® network by visiting www.sigfox.com/
coverage. Blue Connect uses Sigfox® to transfer data to your smartphone.

6
Blue Connect
Blue Fit50 » USER MANUAL
Rinse the probe in clear water and place the usage cap in the external part of the device to
protect the probes.
Place Blue Connect in the swimming pool:
In the pool: Leave it floating in the pool. If needed, you can secure by fixing it to a point of
attachment with the cord and the rubber ring.
In the technical room with Blue Fit50*: For further information, please check our website
www.blueconnect.io or contact your reseller.
NB: Make sure the device is in vertical position and the top part out of the water to allow a
correct communication.
B. Notes
» Do not leave the sensor exposed to air.
» The Sigfox® network connects automatically and sends measurements at regular intervals.
» The sensor may take a few hours to stabilise its parameters after its first immersion in the swimming
pool.
» In case of non-existent Sigfox® coverage, there are two options:
» Blue Connect operates in Bluetooth®. In such case, you must take daily Bluetooth®
measurement(s) for the device to perform its analyser work.
» Blue Extender** allows Blue Connect to connect to your Wi-Fi network. For further information,
visit our website or contact your reseller.
Feel free to watch our Blue Connect start-up video available on www.blueconnect.io (help).
6.
7.
*Blue Fit50 is a Blue Connect accessory. It is available in the Blue Plus pack, or sold separately.
** Sold separately.

7
Blue Connect
Blue Fit50 » USER MANUAL
Blue Connect maintenance
A. Calibration
NB: Calibration is not needed when receiving the device.
Take out the device from the water, pull out the usage cap and rinse the probe in clear water.
Rinse the storage cap with clear water and wipe it.
Activate the Internet (Wi-Fi or 4G) and Bluetooth® on your smartphone.
NB: Stay close to your device throughout the whole calibration process.
In the app, in “Settings“ » “Blue Connect“, press “Calibrate“. A message at the top of the
screen indicates that the device is detected.
Place a pH4 solution in the storage cap and screw it to the device. Then, press “Validate”.
At the top of the screen, you will see the progression of the measurement. Once the pH4
measurement is complete, unscrew the storage cap and rinse the probe. Empty, rinse5and
wipe the cap.
1.
2.
3.
4.
5.
5Always clean the probe and storage cap with clear water after using a calibration product to avoid mixtures.

8
Blue Connect
Blue Fit50 » USER MANUAL
Place a pH7 solution in the storage cap and screw it to the device. Then, press “Validate”.
At the top of the screen, you will see the progression of the measurement. Once the pH7
measurement is complete, unscrew the storage cap and rinse the probe. Empty, rinse and
wipe the cap.
Validate calibration.
Place the usage cap and place back Blue Connect in the swimming-pool.
NB: Calibration products are for single use only. Never use them twice. Please contact your reseller to
get new ones.
B. Battery replacement
The battery needs to be replaced approximately every two years. Please contact your reseller to get a
new one.
NB: To ensure an optimized battery life, put Blue Connect into standby mode when the pool is in
winterization.
The box includes:
6.
7.
8.

9
Blue Connect
Blue Fit50 » USER MANUAL
Installation:
In “Settings“ » “Blue Connect“, press “Battery replacement“.
Take out the device from the water, remove the rubber ring and the usage cap and place
Blue Connect on the storage cap.
Wipe it and start the procedure in a dry and clean place.
Remove the adhesive tape and unscrew the upper part of the device. This is a left-hand
thread. Unscrew it in a clockwise direction. Remove the seal and discard it.
Unplug the white connector by pulling the red and black cable. The battery is at the other
end of the cable. Press the plastic rod to release the battery, and remove it by pulling the
cable.
1.
2.
4.
3.
5.

10
Blue Connect
Blue Fit50 » USER MANUAL
Place the battery at the bottom of the cavity until it is secure. Then, plug in the connector.
Place the new seal supplied with the battery on the screw thread of the upper part of the
device. Close the upper part. This is a left-hand thread. Screw it counter-clockwise.
Paste the new adhesive tape supplied with the battery and replace the ring. Then, place the
usage cap and place Blue Connect back in the water.
6.
7.
8.
Autres manuels pour connect
2
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Système de filtration d'eau populaires d'autres marques

Wisy
Wisy LineAir 100 Manuel utilisateur

Schaffner
Schaffner Ecosine FN3446 Series Manuel d'utilisation

Pentair
Pentair FLECK 4600 SXT Guide de l'utilisateur

H2O International
H2O International H20-500 Manuel utilisateur

Renkforce
Renkforce 2306241 Manuel utilisateur

Neo-Pure
Neo-Pure TL3-A502 Manuel utilisateur











