Blue Seal Evolution G512 Manuel utilisateur

232423-5
GAS COOKTOP
Series
G512
G514
G516
G518
INSTALLATION AND OPERATION MANUAL

The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless qualified previously in
writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and
design without prior notice.
© Copyright Moffat Ltd. October 2009.
MANUFACTURED BY
Moffat Limited
PO Box 10001
Christchurch
New Zealand
Ph: (03) 389 1007
Fax: (03) 389 1276
WORLD-WIDE BRANCHES
UNITED KINGDOM
Blue Seal
Unit 67, Gravelly Business Park
Gravelly Park
Birmingham
West Midlands
B24 8TQ
Ph: (121) 327 5575
Fax: (121) 327 9711
UNITED STATES
Moffat Inc
3765 Champion Blvd
Winston-Salem
North Carolina 27115
Ph: (336) 661 0257
Fax: (336) 661 9546
CANADA
Serve Canada
22 Ashwarren Road
Downview
Ontario M3J1Z5
Toll Free:800 263 1455
Ph: (416) 631 0601
Fax: (416) 631 0315
www.servecanada.com
www.moffat.com
NEW ZEALAND
Christchurch Auckland
Moffat Limited Moffat Limited
PO Box 10-001 4 Waipuna Road
16 Osborne Street Mt Wellington
Christchurch Auckland
Ph: (03) 389 1007 Ph: (09) 574 3150
Fax: (03) 389 1276 Fax: (09) 574 3159
AUSTRALIA
Victoria New South Wales
Moffat Pty Limited Moffat Pty Limited
740 Springvale Road 3/142 James Ruse Drive, Rose Hill
Mulgrave, Melbourne PO Box 913, Smithfield
Victoria 3171 Sydney, N.S.W. 2142
Ph: (03) 9518 3888 Ph: (02) 8833 4111
Fax: (03) 9518 3838 Fax: (02) 8833 4133
Western Australia Queensland
Moffat Pty Limited Moffat Pty Limited
67 Howe Street 30 Prosperity Place
Osbourne Park Geebung, Brisbane
WA 6017 Queensland 4034
Ph: (08) 9202 6820 Ph: (07) 3630 8600
Fax: (08) 9202 6836 Fax (07) 3630 8623

1
Blue Seal Gas Cooktops
G512 Gas Cooktop 300mm wide.
G514 Gas Cooktop 600mm wide.
G516 Gas Cooktop 900mm wide.
G518 Gas Cooktop 1200mm wide.
Introduction .............................................................................................. 2
Specifications ............................................................................................ 3
Model Numbers Covered in this Specification
General
Gas Supply Requirements
Gas Connection
Dimensions ................................................................................................ 5
Installation .............................................................................................. 10
Installation Requirements
Unpacking
Location
Clearances
Assembly
Gas Connection
Commissioning
Operation ................................................................................................. 14
Operation Guide
Description of Controls
Open Burners ('F' - Flame Failure Option)
Open Burners ('PF' - Pilot and Flame Failure Option)
Griddle
Cleaning and Maintenance ...................................................................... 17
General
After Each Use
Daily Cleaning
Weekly Cleaning
Periodic Maintenance
Fault Finding............................................................................................ 21
Gas Conversion and Specifications.......................................................... 22
Conversion Procedure
Gas Specifications
Replacement Parts List............................................................................ 29
Contents

2
2
Introduction
We are confident that you will be delighted with your BLUE SEAL COOKTOP, and it will become a most
valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new BLUE SEAL COOKTOP, there are two important
things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well
spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance,
contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your question.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
WARNING:
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN APROMINENT
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
WARNING:
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK
OF FIRE.
• THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
• ITIS RECOMMENDED THAT AREGULAR INSPECTION IS MADE BY ACOMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
• DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.
• DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
C
AUTION
:
This appliance is;
•
For professional use and is to be used by qualified persons only.
•
Only authorised service persons are to carry out installation, servicing and
gas conversion operations.
•
Components having adjustments protected (e.g. paint sealed) by the
manufacturer should not be adjusted by the user / operator.
•
DO NOT operate the appliance without the legs supplied fitted.

3
Specifications
Model Numbers Covered in this Specification
G512D-[1]-[2] 2 Open Burners.
G512C -[2] 300mm Griddle.
G514D-[1]-[2] 4 Open Burners.
G514C-[1]-[2] 2 Open Burners + 300mm Griddle.
G514B -[2] 600mm Griddle.
G516D-[1]-[2] 6 Open Burners.
G516C-[1]-[2] 4 Open Burners + 300mm Griddle.
G516B-[1]-[2] 2 Open Burners + 600mm Griddle.
G516A -[2] 900mm Griddle.
G518D-[1]-[2] 8 Open Burners.
G518C-[1]-[2] 6 Open Burners + 300mm Griddle.
G518B-[1]-[2] 4 Open Burners + 600mm Griddle.
G518A-[1]-[2] 2 Open Burners + 900mm Griddle.
[1] - Open Burner Options;
F - With Flame Failure Protection.
PF - With Pilot and Flame Failure Protection.
[2] - Base Stand Options;
B - Bench Mount.
CB - Cabinet Base (excluding G512 series).
LS - Leg Stand (excluding G512 series).
RB - Refrigerated Base (G516 and G518 series only).
General
A heavy duty, high efficiency Cooktop for modular kitchens. It has a high option Cooktop / Griddle
arrangement and is available either on industrial adjustable feet or on robust rollers. Griddle options
with 4 models of base unit available (except G512 model). Fitted with either 'Individual Flame
Failure' (F) or 'Pilot and Flame Failure' (PF) option for each open burner. Griddles are fitted with
pilot, flame failure and piezo ignition as standard. Easy clean stainless steel external finish.
Gas Supply Requirements
(*) NOTE:
• The burner operating pressure is to be measured at the manifold test point with two
burners operating at the 'High Flame' setting.
• NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
• TOWN GAS Only - The burner operating pressure is to be adjusted using the Town Gas
adjustable gas regulator supplied.
• Refer to the ‘Gas Conversion and Specifications section of this manual for further details.
Natural Gas LP Gas / Butane Town Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
(26,540 Btu/hr)
28 MJ/hr
(26,540 Btu/hr)
28 MJ/hr
(26,540 Btu/hr)
- each 300mm Griddle Section 21 MJ/hr
(19,900 Btu/hr)
21 MJ/hr
(19,900 Btu/hr)
21 MJ/hr
(19,900 Btu/hr)
Supply Pressure 1.13 - 3.40 kPa
(4.5” -13.5” w.c.)
2.75 - 4.50 kPa
(11” -18” w.c.)
0.75 - 1.50 kPa
(3” - 6” w.c.)
Burner Operating Pressure 0.95 kPa (*)
(3.7” w.c.)
2.6 kPa (*)
(10.0” w.c.)
0.63 kPa (*)
(2.5” w.c.)
Gas Connection See ‘Gas Connection’ information overleaf

4
Specifications
Gas Connection
Gas supply connection point is located at the rear of the appliance, approximately 130mm from the
right hand side, 32mm from the rear and 655mm from the floor (55mm for bench top – B models)
and is reached from beneath the appliance. (Refer to the ‘Dimensions’ section). With the exception
of the G512C and G512D models which are 100mm from the right hand side, 32mm from the rear
and 70mm from the floor.
Connection is ½" BSP male thread (for G512C and G512D models).
Connection is ¾" BSP male thread (for all other models).

5
Dimensions
Dimensions for Bench Models
G512-B
G514-B
G516-B
G518-B
Refer to Page 9 for Cooktop options
= Rating Plate Location for
this option.
R
R

6
Dimensions
Dimensions for Cabinet Base Models
G512 models - not available in Cabinet Base option.
G514-CB
G516-CB
G518-CB
Refer to Page 9 for Cooktop options
= Rating Plate Location for
this option.
R
R

7
Dimensions
Dimensions for Leg Stand Models
G512 models - not available in Leg Stand Base option.
G514-LS
G516-LS
G518-LS
Refer to Page 9 for Cooktop options
= Rating Plate Location for
this option.
R
R

8
Dimensions
Dimensions for Refrigerated Base Models
G512 and G514 models - not available in Refrigerated Base option.
G516-RB
G518-RB
Refer to Page 9 for Cooktop options
= Rating Plate Location for
this option.
R
R
Autres manuels pour Evolution G512
1
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Blue Seal plaque de cuisson

Blue Seal
Blue Seal IN512 Manuel utilisateur

Blue Seal
Blue Seal Evolution Series Manuel utilisateur

Blue Seal
Blue Seal Blue Seal Evolution G518C-B Mode d’emploi

Blue Seal
Blue Seal Evolution G512 Manuel utilisateur

Blue Seal
Blue Seal G50-D Manuel

Blue Seal
Blue Seal G57 Manuel utilisateur

Blue Seal
Blue Seal G51 Manuel utilisateur

Blue Seal
Blue Seal G512 Series Manuel utilisateur

Blue Seal
Blue Seal Evolushion E512 Manuel utilisateur

Blue Seal
Blue Seal Blue Seal E512C-B Mode d’emploi