BIRD 4043 Manuel utilisateur

Directional Power Sensor
Model 4043
Operation Manual
©Copyright 2019 by Bird Technologies, Inc.
Instruction Book Part Number 920-4043 Rev. E
The Bluetooth® word mark and logos are
registered trademarks owned by Bluetooth SIG, Inc.

i
Safety Precautions
The following are general safety precautions that are not necessarily related to
any specific part or procedure, and do not necessarily appear elsewhere in this
publication. These precautions must be thoroughly understood and apply to all
phases of operation and maintenance.
WARNING
Keep Away From Live Circuits
Operating Personnel must at all times observe general safety precautions. Do
not replace components or make adjustments to the inside of the test
equipment with the high voltage supply turned on. To avoid casualties,
always remove power.
WARNING
Shock Hazard
Do not attempt to remove the RF transmission line while RF power is present.
WARNING
Do Not Service Or Adjust Alone
Under no circumstances should any person reach into an enclosure for the
purpose of service or adjustment of equipment except in the presence of
someone who is capable of rendering aid.
WARNING
Safety Earth Ground
An uninterruptible earth safety ground must be supplied from the main
power source to test instruments. Grounding one conductor of a two
conductor power cable is not sufficient protection. Serious injury or death
can occur if this grounding is not properly supplied.
WARNING
Resuscitation
Personnel working with or near high voltages should be familiar with modern
methods of resuscitation.
WARNING
Remove Power
Observe general safety precautions. Do not open the instrument with the
power applied.

Safety Precautions
ii
Safety Symbols
Note: Calls attention to supplemental information.
Warning Statements
The following safety warnings appear in the text where there is danger to
operating and maintenance personnel, and are repeated here for emphasis.
Refer to pages 3 and 7.
WARNING
Warning notes call attention to a procedure, which if not correctly
performed, could result in personal injury.
CAUTION
Caution notes call attention to a procedure, which if not correctly performed,
could result in damage to the instrument.
WARNING
Leaking RF energy is a potential health hazard. Never attempt to connect or
disconnect equipment from the transmission line while RF power is being
applied. Severe burns, electrical shock, or death can occur.

Directional Power Sensor 4043
iii
Safety Statements
USAGE
ANY USE OF THIS INSTRUMENT IN A MANNER NOT SPECIFIED BY
THE MANUFACTURER MAY IMPAIR THE INSTRUMENT’S SAFETY
PROTECTION.
USO
EL USO DE ESTE INSTRUMENTO DE MANERA NO ESPECIFICADA
POR EL FABRICANTE, PUEDE ANULAR LA PROTECCIÓN DE
SEGURIDAD DEL INSTRUMENTO.
BENUTZUNG
WIRD DAS GERÄT AUF ANDERE WEISE VERWENDET ALS VOM
HERSTELLER BESCHRIEBEN, KANN DIE GERÄTESICHERHEIT
BEEINTRÄCHTIGT WERDEN.
UTILISATION
TOUTE UTILISATION DE CET INSTRUMENT QUI N’EST PAS
EXPLICITEMENT PRÉVUE PAR LE FABRICANT PEUT
ENDOMMAGER LE DISPOSITIF DE PROTECTION DE
L’INSTRUMENT.
IMPIEGO
QUALORA QUESTO STRUMENTO VENISSE UTILIZZATO IN MODO
DIVERSO DA COME SPECIFICATO DAL PRODUTTORE LA
PROZIONE DI SICUREZZA POTREBBE VENIRNE COMPROMESSA.

Safety Precautions
iv
SERVICE
SERVICING INSTRUCTIONS ARE FOR USE BY SERVICE - TRAINED
PERSONNEL ONLY. TO AVOID DANGEROUS ELECTRIC SHOCK, DO
NOT PERFORM ANY SERVICING UNLESS QUALIFIED TO DO SO.
SERVICIO
LAS INSTRUCCIONES DE SERVICIO SON PARA USO EXCLUSIVO
DEL PERSONAL DE SERVICIO CAPACITADO. PARA EVITAR EL
PELIGRO DE DESCARGAS ELÉCTRICAS, NO REALICE NINGÚN
SERVICIO A MENOS QUE ESTÉ CAPACITADO PARA HACERIO.
WARTUNG
ANWEISUNGEN FÜR DIE WARTUNG DES GERÄTES GELTEN NUR
FÜR GESCHULTES FACHPERSONAL. ZUR VERMEIDUNG
GEFÄHRLICHE, ELEKTRISCHE SCHOCKS, SIND
WARTUNGSARBEITEN AUSSCHLIEßLICH VON QUALIFIZIERTEM
SERVICEPERSONAL DURCHZUFÜHREN.
ENTRENTIEN
L’EMPLOI DES INSTRUCTIONS D’ENTRETIEN DOIT ÊTRE RÉSERVÉ
AU PERSONNEL FORMÉ AUX OPÉRATIONS D’ENTRETIEN. POUR
PRÉVENIR UN CHOC ÉLECTRIQUE DANGEREUX, NE PAS
EFFECTUER D’ENTRETIEN SI L’ON N’A PAS ÉTÉ QUALIFIÉ POUR
CE FAIRE.
ASSISTENZA TECNICA
LE ISTRUZIONI RELATIVE ALL’ASSISTENZA SONO PREVISTE
ESCLUSIVAMENTE PER IL PERSONALE OPPORTUNAMENTE
ADDESTRATO. PER EVITARE PERICOLOSE SCOSSE ELETTRICHE
NON EFFETTUARRE ALCUNA RIPARAZIONE A MENO CHE
QUALIFICATI A FARLA.

Directional Power Sensor 4043
v
About This Manual
This manual covers the operating and maintenance instructions for the
following models:
Changes to this Manual
We have made every effort to ensure this manual is accurate. If you discover
any errors, or if you have suggestions for improving this manual, please send
your comments to our Solon, Ohio factory. This manual may be periodically
updated. When inquiring about updates to this manual refer to the part number
and revision on the title page.
Chapter Layout
Introduction — Describes the features of the 4043 Directional Power Sensor.
Installation — Describes how to set up and prepare the 4043 Power Sensor
for use.
Maintenance — This section provides the specifications for the 4043 Power
Sensor as well as a model identification table.
4043 Series - Directional Power Sensors

vi
Table of Contents
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
Warning Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
Safety Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Changes to this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Chapter Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Purpose and Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Chapter 2 Serial Communication Model . . . . . . . . . . . . . . . . . . . . . . .2
Serial Communication Power Sensor Installation . . . . . . . . . . . . . . . . . . . . . . 3
Chapter 3 Bluetooth Communication Model. . . . . . . . . . . . . . . . . . . .5
Bluetooth Communication Model Installation . . . . . . . . . . . . . . . . . . . . . . . . 7
Pairing the 4043 Bluetooth Sensor with the Bird RF Meter App . . . . . . . 7
Bluetooth Power Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Internal Battery Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
External Power Supply Cable Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chapter 4 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Chapter 5 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Model Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

1
Chapter 1 Introduction
Purpose and Function
The Bird 4043 Series Directional Power Sensors are digital power sensors. The
4043 Series power sensors are typically used to measure forward and reflected
average power on a 50 ohm RF transmission line with a maximum 500 watt
forward and maximum 50 watt reflected power levels in a frequency band with
an overall range of 144 to 940 MHz. See
"Model Identification" on page 12
for
specific frequency ranges and model features. The 4043 sensor also provides a
VSWR reading.
Figure 1 4043 Power Sensor
The model 4043 power sensor is available with two different types of
communication interface:
RS-485 Serial Communication - designed for use with the Bird Channel
Power Monitor (CPM) in rack mounted communications systems.
See
"Serial Communication Model" on page 2
.
Bluetooth Communication - designed for use with vehicle mounted
communications systems, or as portable test equipment.
See
"Bluetooth Communication Model" on page 5

2
Chapter 2 Serial Communication Model
The 4043 Sensors with an RS-485 serial bus are designed to transfer data to and
from a CPM. The serial bus also serves as the power sensor’s power supply.
Each sensor is equipped with two RJ-25 jacks for serial communications, RF
input and output connectors, and a status indicator. See
Figure 2
.
Figure 2 Bird 4043, RS-485 Serial Communication Power Sensor
Each sensor is equipped with two RJ-25 jacks, either jack may be connected to a
CPM. The second RJ-25 jack may be used to extend the RS-485 bus to another
digital sensor. See
Figure 3 on page 3
. Multiple digital sensors may be serially
connected in this fashion, allowing as many as 16 sensors to be connected to a
CPM.
If multiple 4043 sensors are to be connected serially, each one is assigned a
unique address via the CPM. When each 4043 is connected to the CPM, prior to
connecting any additional 4043 sensors, they must be assigned an address by
the CPM, only then may an additional sensor be connected serially.
A termination plug must be used in the open RJ-25 jack on the rear panel of the
CPM or the open RJ-25 jack of the final digital sensor in the chain.
Features
RF Input N-Type (male) connector (shown), other connector types
available, see
"Model Identification" on page 12
RF Output N-Type (female) connector (shown), other connector types
available, see
"Model Identification" on page 12
Data Connectors
RJ-25 connector provides power and data connection. Only
one connector is required, second connector may be used to
extend RS-485 bus to additional digital sensors.
RJ-25 termination plug must be installed in unused jack or in
the Open port on the CPM.
Status LED Solid green: Power applied.

Directional Power Sensor 4043
3
Serial Communication Power Sensor Installation
The Bird 4043 Series Directional Power Sensors are designed to be used for
continuous power monitoring of Land Mobile Radio (LMR) systems. The 4043
can provide real-time RF forward and reflected power and VSWR
measurements.
This procedure is an example of one possible cable configuration, based on the
connection diagram in
Figure 3
.
1. Disable RF power for transmission lines to be disconnected.
2. Connect combiner's RF output cable to the 4043 RF input.
Figure 3 CPM, RS-485 Serial Connection Diagram
3. Connect 4043's RF output connector to the antenna cable.
4. Repeat step
1
through
3
for any additional 4043 power sensors.
5. Install RJ-25 termination plug in unused digital sensor RJ-25 port on the rear
panel of the CPM (if available), or in the last sensor installed in the digital
sensor chain.
6. Connect a data/power cable from the CPM to 4043 power sensor.
WARNING
Leaking RF energy is a potential health hazard. Never attempt to connect or
disconnect equipment from the transmission line while RF power is being
applied. Severe burns, electrical shock, or death can occur.
Table des matières
Autres manuels BIRD Accessoires

BIRD
BIRD 5012 Manuel utilisateur

BIRD
BIRD 5011 Manuel utilisateur

BIRD
BIRD 5009 Manuel utilisateur

BIRD
BIRD 7022 Manuel utilisateur

BIRD
BIRD Thruline 4028A250K Manuel utilisateur

BIRD
BIRD 4044 Series Manuel utilisateur

BIRD
BIRD 4043E Manuel utilisateur

BIRD
BIRD 5012D Manuel utilisateur

BIRD
BIRD 4042E Manuel utilisateur

















