Birch BD-408e Manuel utilisateur

NOTICE
This equipment has been tested and found comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interface when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interface to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interface in which case the user will be
required to correct the interface at his own expense.
*
All brand and trademark are belonged to their respective owner.
*
Specifications are subject change without notice.
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
condition: (1) This device may not cause
harmful interface, and (2) This device must
accept any interface received, including
Interface that may cause undesired operation.
1

Operation Manual
2

Index
1Instroduction«««««««««««««««««««««««««««««««««««««««««««««««« 4
Installation«««««««««««««««««««««««««««««««««««4
Recommended Steps«««««««««««««««««««« 4
Configuration Flowchart««««««««««««««««« 5
String Output Flowchart««««««««««««««««««5
Default Setting««««««««««««««««««««««««««««« 6
Manual Label Layout««««««««««««««««««««« 7
Frequent Question«««««««««««««««««««««««« 8
2Interface««««««««««««««««««««««««««««««««««««««««««««««««««««««« 10
Host Interface«««««««««««««««««««««««««««««« 10
Keyboard Wedge«««««««««««««««««««««««««« 11
RS-232C«««««««««««««««««««««««««««««««««««««15
Wand Emulation (Linker or Pen)«««««««18
OCIA««««««««««««««««««««««««««««««««««««««««« 20
3System Control««««««««««««««««««««««««««««««««««««««««««««« 21
4Code Option««««««««««««««««««««««««««««««««««««««««««««««««« 26
UPC-A««««««««««««««««««««««««««««««««««««««««26
UPC-E««««««««««««««««««««««««««««««««««««««««28
EAN-13 (ISBN/ISSN) «««««««««««««««««««« 30
EAN-8«««««««««««««««««««««««««««««««««««««««« 32
CODE-39 (CODE-32) ««««««««««««««««««« 34
Interleaved 2 of 5 (Odd S-code) «««««« 36
Industrial 2 of 5«««««««««««««««««««««««««««««38
Matrix 2 of 5«««««««««««««««««««««««««««««««« 40
China Post 2 of5«««««««««««««««««««««««««« 42
Codabar/NW7«««««««««««««««««««««««««««««« 44
Code-128««««««««««««««««««««««««««««««««««« 46
Code-93««««««««««««««««««««««««««««««««««««« 48
Code-11««««««««««««««««««««««««««««««««««««« 50
MSI/Plessey«««««««««««««««««««««««««««««««« 52
UK/Plessey««««««««««««««««««««««««««««««««« 54
Telepen«««««««««««««««««««««««««««««««««««««« 56
IATA«««««««««««««««««««««««««««««««««««««««««« 58
5String Format««««««««««««««««««««««««««««««««««««««««««««««««60
Preamble/Postamble««««««««««««««««««««« 60
Prefix/Suffix««««««««««««««««««««««««««««««««« 61
Character Insertion««««««««««««««««««««««««62
Other Control««««««««««««««««««««««««««««««« 64
6Cable Type««««««««««««««««««««««««««««««««««««««««««««««««««««66
7Test Chart««««««««««««««««««««««««««««««««««««««««««««««««««««« 68
8ASCII Code/Hexdecimal Table«««««««««««««««««««««««71
3

Installation
1) First of all, you must make sure that the power is disconnected
form your equipment before connecting the scanner. Beside, you
also have to check the cable connector of the scanner match
your equipment interface correctly.
2) Boot up your computer after connecting the scanner with your
equipment, the scanner will make a long music and light the LED,
above scanner to indicate a successful power on. Trigger the
button, the scan line in front of scanner will active. Now you can
start to set programming optimal usage.
*
If any of the above operation is not right, turn off the power
immediately and check any improper connections. Go through all
abovestepsagain.
Recommened Steps
When the required settings have been configured, all settings
are stored in non volatile memory of scanner after reading EXIT
label. There are recommended steps as follows.
1) Set right host interface for your scanner at
/
10.
(The scanner is in factory default as bold label)
2) Set interface to optimize protocol of scanner with your host in
Charter 2.
3) Set system control of scanner, such as specific adjustments
double confirm, power saving, indicator and scanning mode
which you prefer usage in Chapter 3.
4) Set code option of scanner for your usage in Chapter 4. You must
make sure to enable the symbology first, then Min./Max. code
length, code ID checksum and truncate digits are also convered.
5) Set string format of the scanner, such as preamble, postamble,
prefix, suffix, code ID and code name transmission for your
application in Chapter 5.
*
If any of the error step is processing, scanner will generate a 5
wanrrying beeps to indicate an invaild setting. You have to take care
this matter and set correctly again.
*
If still not work properly. Please contact with dealer.
Operation Manual
4

Configuration Flowchart
String Output Flowchart
Preamble
Prefix
Code Name
Code ID
Code Data
CodeLength
Suffix
Postamble
Enter
Programming
Mode
Finish ASCII
Code or Decimal
Value Setting
Select Function
Label
Interface Default
Exit & Interface Default
Function
PROGRAM
Decimal
(10'sValue)
Hexdecimal
(High Byte)
Decimal
(1'sValue)
Hexdecimal
(Low Byte)
SET
EXIT
ABORT
VERSION DATE
SETTING LIST
DEFAULT
Prefixor
Suffix
Only
Set ASCII Code
Set Decimal Value
Exit With Save
Exit Without Save
Exit & Default
Exit & Version List
Exit & Setting List
5
Introduction
1

Default Setting
Length TruncateCode
Type
Read
Enable
Min.
Max.
Leading
Ending
Code
ID
UPC-A
3
- - 0 0 A
UPC-E
3
- - 0 0 E
EAN-13
3
- - 0 0 F
EAN-8
3
- - 0 0 FF
Code-39
3
0 0 0 0 M
Interleaved 2 of 5 6 0 0 0 I
Industrial 2 of 5 4 0 0 0 H
Matrix 2 of 5 4 0 0 0 G
China Post 2 of 5 11 11 0 0 J
Codabar/NW7
3
4 0 0 0 N
Code-128
3
0 0 0 0 K
Code-93 4 0 0 0 L
Code-11 4 0 0 0 O
MSI/Plessey 4 0 0 0 P
UK/Plessey 4 0 0 0 R
Telepen 4 0 0 0 S
IATA 4 0 0 0 Q
Adjustment Value Result
Beep Loudness 05 Level 5
Beep Tone 24 2.4 KHz
Beep Duration 06 60mSec
Beep Tone1 12 1.2 KHz
Beep Duration1 06 60mSec
Stand-byTime 15 15 Sec
Active Time 20 200mSec
Sleep Time 20 200mSec
Good-read Delay 50 500mSec
Double Confirm Times 01 Once
Inter-char. Delay 01 1mSec
Transmit Delay 00 0mSec
Response Delay 30 3 Sec
Add-on Wait Time 50 500mSec
Margin Delay 10 100mSec
Preamble Data1 0016 <NULL>
Preamble Data2 0016 <NULL>
Postamble Data1 0D16 <CR>
Postamble Data2 0A16 <LF>
Prefix Data(All Datas) 0016 <NULL>
Suffix Data (All Datas) 0016 <NULL>
Add-on Insertion (All Datas) 0016 <NULL>
Insertion1-4 (Position & All Datas) 0016 <NULL>
Concatenation Data 2916 <GS>
Operation Manual
6

Manual Label Layout
The scanner must be set by reading the barcode labels in
manual. The discription of label is as follows.
*
The factory default settings are indicated by bold symbols.
Disable DZA
*DZA*
Enable DZB
*DZB*
Spare Function
Disable DYA
*DYA*
Enable DYB
*DYB*
Truncate
Leading BAO
*BAO*
(Range:0010-1510)
Truncate Ending BAP
*BAP*
(Range:0010-1510)
Code ID AAA
*AAA*
(Range:0016-FF16 ASCIICode)
Specific Adjustments
Truncate Leading Zero
EXIT
UPC-A
*/$%END*
Code Option
4
Truncate Leading / Ending: The
leading or ending digits of barcode
data characters can be truncated
when these values are set to non
zero. It will be read nothing else only
beeps when the truncate value is
more than barcode data digits or the
value of Truncate Leading is overlap
with the Ending. The maximum value
of Truncate digits is 15.
Code ID: A Code ID is a character
27
Section
Title
Exit
Program
Command
For RS-232C
Selection
Label
Default
Setting
Selection
Description
Chapter
Number
Chapter
Title
Page
Number
Function
Title
Adjustment
(ASCII Code or
Decimal Value)
Group
Line
Selection
Label
Range
Description
Function
Description
7
Introduction
1

Frequent Question
Q: Why scanner block the keyboard operation?
A: Check the cable connection with your equipment, then turn power
on again.
Q: If scanner has a good read beep but nothing transferring
after read a label.
A: Using the SETTING LIST at
/
10 to show what current setting of
scanner is, or reset to Default, (or select right Interface default if
scanner to be change another interface used), then re-program
scanner again.
Q: If scanner dosen't need an Enter character addition after
each barcode label transmission.
A: Refer to postamble transmission at
/
60, then set Disable.
Q: If scanner needs to read single digit code.
A: Refer to Min. code length of code option use "01" in Chapter 4 for
single code readable.
Q: If scanner isn't able to discriminate an unknown label, but
read manual very well.
A: Refer to code name at
/
64 to set Enable, read a barcode label,
then you will know what symbology is read. Beside, it maybe
need to verify checksum. Refer to verify checksum of code option
in Chapter 4, and set Enable.
Q: If scanner transfers character very slow or loses some
characters on screen in keyboard interface after reading a
label.
A: You may set caps lock to be Alt+Keypad at
/
11. Otherwise, it
maybe mis-match of transmission rate, therefore, you can adjust
an appropriate Inter-char. Delay to match your equipment. See
/
11.
Q: If scanner want to read a label as function key for your
apprication.
A: Refer to function key simulation at
/
11 and set Enable, then
scanner can transmit a code as function key. It is used for
keyboard interface only. Beside, you must make sure that a label
is encoded as function key, and its ASCII code is from 0016 to
1F16 You can refer to ASCII code table at
/
71.
Operation Manual
8

Q:Could I change scanner into different type interface directly?
A: You can change factory interface default for other type interface.
By plug different cable, program scanner and set right interface to
exit, then the scanner will be change to another interface.
However, you must make sure what cable you need. Refer Cable
Type to /66, 67.
Q: How to configure scanner via RS-232C?
A: Next to the selection description, you will find a frame command,
such as AAB. These commands can be sent to scanner with
RS-232C interface. You must make sure that scanner is the same
protocal as your equipment of RS-232C, and light source of
scanner has been actived by pressing button.
Example Beep Loudness Level "10", Good-read Beep "Enable"
To configure the reguired commands proceed as follows:
Send as: <ESC>(1B16) ïCommand(s)ï<CR>(0D16)
Send <ESC>ïBACï%01ï%00ï%OKïCEBï<CR>
︸︸︸︸︸
Beep 1 0 SET Good-read
Londness Level Beep Enable
*
Call to the dealer if scanner dose not work properly.
9
Introduction
1

You can change factory
interface default for other type
interface. By plug different
cable, program scanner and
set right interface to exit, then
the scanner will be change to
another interface. However,
you must make sure what
cable you need. Refer Cable
Type to
/
66, 67.
DEFAULT: All settings are
reset as bold label, but
exclude interface setting.
VERSION DATE: You can get
the software date of decoder
on screen. It is important for
maintanace.
SETTING LIST: First it is
recommended that you need
to excute a text editor
program (such as PE2 and
Word) for keyboard interface,
or excute a terminal program
(such as Hyper Terminal) for RS-232. Then scanner will transmit
current settings on screen.
ABORT: If you have a mis-setting or want to skip this current
configuration during you are programming, using this function, all
front settings are aborted before you set EXIT to finish
programming.
*
Programming will be finished while each label of miscellany is
read.
Keyboard Wedge
*/$%C00*
RS-232C
*/$%C01*
WAND EMULATION
*/$%C02*
OCIA
*/$%C03*
Spare Interface
*/$%C04*
Interface Default
DEFAULT (without Interface)
*/$%DEF*
VERSION DATE
*/$%VER*
SETTING LIST
*/$%LST*
ABORT
*/$%ESC*
Miscellany
PROGRAM
*/$%STR*
Host Interface
Operation Manual
10
Table des matières
Autres manuels Birch Lecteur de codes-barres
Manuels Lecteur de codes-barres populaires d'autres marques

POSMicro
POSMicro Datalogic PowerScan D7100 Manuel utilisateur

Marson
Marson MT780 Guide de configuration rapide

NCR
NCR RealPOS Manuel utilisateur

Motorola
Motorola SE3300 Guide de configuration rapide

Element
Element P130BT Manuel utilisateur

Motorola
Motorola Symbol LS3008 Manuel d'installation et d'exploitation