Bigeyes BE-X9 Manuel utilisateur

WiFi+GSM+RFID Smart Alarm System
User Manual
When designing, this system be added many amazing & practical
new features, to make sure a better smart life.

1. Pure WiFi version, WiFi+GSM version optional.
2. Android & iOS APP operation. User can do all settings via APP.
3. Support working with WiFi camera. The App integrated the IP camera's to realize the video record, send pic to user Email when
system alarm.
4. Support 10 remote controls, 24 wireless + 4 hardwired sensors.
5. Zone 1 to 16 can be customized the SMS text message content.
6. A powerful 20 slaves wireless smart home control lighting, appliances etc.
7. App detection system per 4 hours: AC power OK or not; system ARM OR DISARM. Accessories power lower or not; connect to panel or not.; Zone
has accessories or not... Check the all system clearly, get system status in time.
8. Support ADEMCO Contact ID Protocol. It can work with CMS (Central Monitor System).
9. Delay Alarm/External & Internal siren On/Off for any zone.
10. Low-voltage sensor/sensor-lost be monitored.
11. RFID tag to Arm/Disarm (optional)
Key Features
1. Power supply: input AC=100~240V, output DC=12V
2. Static current: <50mA (when not in charging, excluding wired detectors)
3. Alarm current: <120mA (excluding wired siren)
4. GSM transmission power: 2W
5. WiFi frequency: 2.4G, built-in wireless internet protocol IEEE802.11b/g and TCP/IP protocol stack
6. WiFi receiving sensitivity: -86dbm; Emitting power: 18dbm
7. GSM frequency: 850/900/1800/1900MHz
8. Back-up battery: 3.7V/800mA; Standby time: 8 hours; Full charge time: 12 hours
9. Wireless receiving distance: >100 meters (open space)
10. Wireless transmission distance: >100 meters (open space)
11. Working condition: Temperature -10°C~70 °C, RH 5%~95%
Technical Information
1

Zones’Type: 1 Defend Line, 2 Defend Line, 24-Hour defend Line
Defence Line 1: Which must pass Door window, balcony and boundary etc, which consists of wireless Door Sensor, Wireless Motion Sensor.
Defence Line 2: Which must pass Saloon, Lobby, Apartment and Living-Room etc. Which consists of Wireless Wide-Angle Motion Sensor.
24-Hours Defend Line: 24-Hour zones, This attribute can not be modiÞed. In arm or disarm or stay mode, once the sensor in these zones be
triggered, system will alarm immediately, But not drive Siren. Which Consists of SOS Button, Wireless Gas Alarm, Wireless Somke Alarm.
Zones’Attribute Definition:
Font Panel View
LCD Display
Right
Set/Exit
Away Arm
SOS/Delete
UP
Down
Call/#Confi rm
Home/Stay Arm
Left
Conteol home appliances
FRID
Disarm
2

Back Panel View
ON OFF -BEL L+ 34 33 32 31 -12 V+ S+GND A+ NO COM
J12
S3
Button
Cable Slot
WiFi SET/Recovery
SIM Card Slot
Wired Connection
Wired Siren
I/O connector
Button 12V output
(A: Arm disarm; S: SMS)
DC 12V input jack
3

Activate Away Arm
In keypad, touch to activate Away Arm.
Remotely via SMS, send SMS content: xxxx+A0
Remotely via phone, make phone call to alarm system, after pick up, input xxxx#, you
will hear "di" sound, press 1 to activate the Away Arm.
Activate Stay Arm
In keypad, touch to activate the Stay Arm
Remotely via phone, make phone call to alarm system, after pick up, input xxxx#, you
will hear "di" sound, press 2 to active the Stay Arm
In keypad, touch then, input xxxx+OK
Remotely via SMS, send SMS content: xxxx+A2
Remotely via phone, make phone call to alarm system, after pick up, input xxxx#, you
will hear “di” sound, press 3 to disarm.
Disarm
Notice
“xxxx” is the current user code, default user code is “1111”, and default
admin/installer code is “1234”. The system is working with separate wireless
LCD/LED keypads, for activate and deactive operation, please refer to manual
of wireless keypad.
Arm/Disarm System
Basic Alarm Setting
Enter into Setting Status
When system is in Disarm status, push then input admin code,
default “1234”, press “OK” to enter into setting status.
System time setting
When system is in setting status, choose “Time Setting” to modify
the current time. The time will back to default automatically once
the alarm system is complete OFF.
Time Setting
Phone No.Setting
Time Setting
04:54:08
Time Setting
9/11/2013
Time Setting
THU
Press “OK” to select and “ ” to delete the default date, then enter
with new time (XXhours, XXminute, XXsecond). Do same procedure
for date. (XXDate, XXMonth, XXYear) Press “OK” and “◀▶” select the
week, press “OK” to confiall settings.
Alarm Receiving Phone Number
This alarm system can totally preset up to 5 personal emergency
phone numbers for alarm receiving.
4

Phone Groups 1
13800138000
Phone Groups 1
Alarm Call >
Time Setting
Phone No.Setting
·
Push “ ◀▶” toselect the Alarm Call or Alarm SMS, then push “OK”, you can input the number.
1st and 2nd group for setting Alarm SMS, 3rd group for setting Alarm SMS or Alarm Call, 4th&5th groups fot setting Alarm Call.
Basic Alarm Setting
Push “ ” you can delete the existing phone number.
You need touch “Ok” to save,and navigate into next phone number setting menu.
Notice: Maximum digitals fot phone number input is 15.
SMS Number for System System Status
The alarm system can preset one phone number for receiving SMS report of system’s status, including AC
power recover, Arm/Disarm, Host Low Voltage,Sensor Low Voltage.
SMS Setting
Record
SMS Phone No.
13800138000
AC Power Recover
OFF >
Arm/Disarm SMS
OFF >
Host Low Volt
OFF >
Sensor Low Volt
OFF >
Push“ ”to delete exist phone number, enter new mobile phone number. Touch “OK” to save the phone number, it will navigate to event report
selection. Touch “◀▶” to select enabled or disable the event report. AC power recover means when external enlectricity is recover, the alarm system
will send SMS. Arm/Disarm SMS means when alarm system is Armed or Disarmed, the system will send SMS. Host Low Volt means when backup
battery power is low, the system will send SMS. Sensor Low Volt means when battteries run out in wireless sensors, it will send SMS.
5

Basic Alarm Setting
Record Voice Memo
The system allows user to record up to 10 seconds voice memo. When
alarm phone call is picked up, press “5” to listen the voice memo.
SMS Setting
Record
Record
OFF >
Recording Time
10
Push “◀▶” to choose “On” torecord voice, and push “OK” to start voice
recording.
Arm Delay/Exit Delay
The Arm delay or exit delay can allow user to exit protected area before
system is Armed. The time is adjustable from 00 to 59 seconds.
Arm Delay
Alarm Delay
Arm Delay
10
Push “ ” to delete default data, and enter new time. push “OK” to save.
Alarm Delay/Entry Delay
The alarm delay or entry delay can allow user to set alarm delay zones
before system set alarm off. This allow user enter into specific detection
area to disarm the system without triggering alarm.
Basic Alarm Setting
Arm Delay
Alarm delay
Alarm Delay
10
Push “ ” to delete exist data, and input new seconds (e.g 10). lt accpet
time between 00-59. push“OK” to save.
Notice: You need go to [Zone attribute] to enable which zones are belong
to this function, therefore it can work.
Siren Setting
It allows siren time setting for each zone. The siren time can be set from
00-59 minutes. User can choose whether use built-in siren or not.
Siren Setting
Tone Setting
Zone No.
00
Siren Time
01
Built-in Siren
On >
Push “ ” to delete the zone number, and input new zone number from
00-34. Touch “OK” to save
Push “ ” to delete the siren time, and input new siren time, “00” means
disable. Default value is 01
Push “◀▶” to choose “On” to enable built-in siren, and touch “OK” to save.
6

Basic Alarm Setting
Tone setting
Tone setting means the alarm system will make “beep” sound, when
detects system event, such as telephone line cut, Arm/Disarm,
Temperature Alert.
Siren Setting
Tone Setting
Arm/Disarm Tone
Off >
Arm/Disarm Beep
Off >
Push “◀▶” to choose “OK” to save
Call in Setting
The system can receive the phone call via GSM. It allow user to set the
ring times from 1 to 9. When the ring time reach to preset times, it will
pick up the phone call for remotely control
Call in Setting
Program&Delete
GSM Call in Tone
3
Push “ ” to delete exist data. It accpets ring time between 1-9. Push
“OK” to save.
Program&Delete
Use this function to program/delete wireless sensors and accessories
(remote keyfob,wireless LED/LCD keypad). The wireless zone number is
from 00-30. Zone 00 is for programming wireless remote keyfob or
leypads.
Basic Alarm Setting
Call in Setting
Program&Delete
Zone No
00
Program
Delete
Success
Push “ ” to delete the zone number, and input new zone number from
00-30 and push “OK”. push “ ” to choose [program], then push “OK”,
the LCD will display [programming]. Trigger the wireless sensors for two
times, the LCD display [Success], push “OK” to save, you can continue to
enroll more sensors.
Push “ ” to delete the zone number, and input new zone number from
00-30 and push “OK”. push “ ” to choose delete, the LCD will display
[Success], push”OK” to save. This will erase the current sensors in the zone
from the alarm system.
Zone Attribute
The system has advanced zone attribute, it allow user to choose each of
attribute for the zones, it helps user to customize the system, which can
be more suitable fot speciÞc installation. Ensuring the zones with correct
attribute, therefore sensors can work properly.
Zone No
00
Zone Attribute
Upload
Activate >
0 Defence Line >
00Help >
Alarm Delay Off >
Zone Chime Off >
Smart Sensor Off >
7

Basic Alarm Setting
Push “ ” to delete the zone number, and input new zone number from 00-30. push “OK” navigate to next menu. push “OK” you will navigate to last
level menu.
Bypass Sensor: push “◀▶” to choose “Disable” to deactivate/bypass this zone.
Zone type: push “ ” to choose defense line, push “◀▶” to change the value from including 0, 1, 2.
Sensor type: push “ ” to choose sensor type, push “◀▶” to change the sensor type.
Alarm Delay: push “ ” to choose alarm delay off, push “◀▶”to enable or disable the alarm delay.
Zone Chime: push “ ” to choose zone chime off, push “◀▶” to enable or disable this function.
Smart Sensor Off: push “ ” to choose smart sensor off, push “◀▶” to enable or disable this function.
Notice:
[0 Defense line] means Þre, panic alarms, which are belong to 24 hours emergency zone. It will trigger the alarm system, even the system in disarm
status.
[1 Defense line] means perimeter protection, which is belongto perimeter zone. lt will work when alarm system in both AwayArm and Home Arm
modes.
[2 Defense line] means interior protection, which is belong to motion zone. The sensors in this zone will be activated when system is in AwayArm
mode, but will be de-activated, when system in Home Arm/Stay Arm mode.
Zone Number Zone Type Sensors
Sensor Type
Wireless Remote Keyfob
Wireless Sensors
Wireless Sensors
Wireless Sensors
00
01~05
06~14
15~24
25~28
29~32
N/A
Emergency Zone
Perimeter Zone
Motion Zone
Hardwired Zone
FRID
8

Basic Alarm Setting
Default zone number for sensor and keyfob for standard alarm kit
Wireless Remote Wireless Door Sensor Wireless PIR motion Wireless Smoke
00 11 21 02
Upload
The system can either be used as self-monitoring system or monitored by security company. lt's compatible with ADEMC0 Contact ID protocol for
alarm monitoring. lf you want to link the alarm system into alarm monitoring center, you need to do this operation. Moreover, the system not only
upload alarm information, but also upload system's status to central monitoring station.
Zone Attribute Center Phone No. User Code Upload status
Upload 911 0001 Off
Push “ ” to delete exist number, and input new alarm monitoring
centre number. Push “OK” to save, then navigate to next level menu,
push “ ” to delete default user code, and input your user code, push
“OK”to save, then navigate to next level menu, touch " " to choose
disable or enalbe upload status, push “OK” to save, navigate to next
status selection menu.
AC Fail Upload Host Low Volt Sensor Low Volt Manual Test
Off > Off > Off > Off >
Period Test
00000
9
Table des matières
Manuels Système de sécurité populaires d'autres marques

EDM
EDM Solution 6+6 Wireless-AE Manuel utilisateur

Highway Safety Group
Highway Safety Group EA401 Manuel utilisateur

Siren
Siren LED GSM Manuel utilisateur

Detection Systems
Detection Systems 7090i Instructions de montage

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuel utilisateur

Siemens
Siemens FDM273 Manuel utilisateur