Baumer PA418 Manuel utilisateur

V1 | 2/1/2024
EN-US
Operating Manual
PA418
Process display

Table of contents Baumer
ii Operating Manual PA418 | V1
Table of contents
1 About this document .................................................................................................................................. 4
1.1 Purpose and scope of application ....................................................................................................... 4
1.2 Applicable documents ......................................................................................................................... 4
1.3 Labels in this manual .......................................................................................................................... 4
1.4 Warnings in this manual...................................................................................................................... 5
2 General functionality................................................................................................................................... 6
3 Mounting the process display.................................................................................................................... 7
4 Electrical connection of the process display ........................................................................................... 8
4.1 Connection examples.......................................................................................................................... 10
5 Interfaces ..................................................................................................................................................... 12
5.1 LED indicator....................................................................................................................................... 12
6 Operating functions .................................................................................................................................... 14
6.1 Input signal configuration .................................................................................................................... 14
6.2 Configuration of the display................................................................................................................. 16
6.3 Configuration of the limit value outputs ............................................................................................... 20
6.4 Configuration of the analog output ...................................................................................................... 23
6.5 Control input configuration .................................................................................................................. 24
6.6 Set limit values .................................................................................................................................... 26
6.7 Protect programming level via code.................................................................................................... 27

Baumer List of illustrations
V1 | PA418 Operating Manual 3
List of illustrations
Ill. 1 Block diagram of the configuration modules ....................................................................................... 13
Ill. 2 Limit value outputs - Time delay ......................................................................................................... 20
Ill. 3 Limit value outputs - asymmetrical hysteresis..................................................................................... 20

1 | About this document Baumer
4 Operating Manual PA418 | V1
1 About this document
1.1 Purpose and scope of application
This document enables safe and efficient sensor parameterization using various interfaces. The
manual describes the available functions to support installation and software use via the inter-
faces.
The illustrations are examples only. Deviations are at the discretion of Baumer at all times. The
manual is a supplementary document to the existing product documentation.
1.2 Applicable documents
nAvailable for download at www.baumer.com:
▪ Data sheet
▪ Functional and interface description
▪ EU Declaration of Conformity
nAttached to product:
▪ Quickstart
▪ General information sheet (11042373)
1.3 Labels in this manual
Identifier Usage Example
Dialog element Indicates dialog elements. Click the OK button.
Unique name Indicates the names of products,
files, etc.
Internet Explorer is not supported
in any version.
Code Indicates entries. Enter the following IP address:
192.168.0.250

Baumer About this document | 1
V1 | PA418 Operating Manual 5
1.4 Warnings in this manual
Warnings draw attention to potential personal injury or material damage. The warnings in this
manual indicate different hazard levels:
Symbol Warning term Explanation
DANGER Indicates an imminent potential danger with high risk of death or
serious personal injury if not being avoided.
WARNING Indicates potential danger with medium risk of death or (serious)
personal injury if not being avoided.
CAUTION Indicates a danger with low risk, which could lead to light or
medium injury if not avoided.
NOTE Indicates a warning of material damage.
INFO Indicates practical information and tips that enable optimal use of
the devices.

2 | General functionality Baumer
6 Operating Manual PA418 | V1
2 General functionality
The process display is intend for visualizing, monitoring, control and calculation of measured
values in industrial applications.
nFor voltage ±10 V or current ±20 mA
nFor thermocouples J, K, T, N, Pt100
nFor weight, pressure, torsion, strain
nFor potentiometers
n11 supporting points for parameterization of Input characteristic
nThree control inputs, programmable
nDisplay stabilization filter
nLED display, 5-digit, 3-color, programmable
nFunction tare, min, max
nDIN housing 96 x 48 mm

Baumer Mounting the process display | 3
V1 | PA418 Operating Manual 7
3 Mounting the process display
1
3
2
Instruction:
a) Prepare the cut-out according to the dimensions.
b) Push device (1) with seal (2) into the cut-out.
c) Secure the device from behind using the clamping frame (3).
d) Perform the electrical connection.

4 | Electrical connection of the process display Baumer
8 Operating Manual PA418 | V1
4 Electrical connection of the process display
Instruction:
a) Make sure the device is disconnected from power supply and not live.
b) Connect the device according to the pin assignment.
Pin assignment (at rear)
2
1
-+
2
14
3
54
387
621
4
5
6
1
2
3
1
11
64
2
-
+
4 5
21 3
Operating voltage (1)
Pin VAC VDC
1 Phase -
2 Neutral +
Input signal (2)
Pin Current/voltage
1 Sensor supply -
2 Sensor supply +24V
3 n.c.
4 n.c.
5 Current input +
6 Voltage input +
7 n.c.
8 Current/voltage -
Pin Thermocouple Pt100
1 n.c. n.c.
2 n.c. n.c.
3 n.c. n.c.
4 n.c. Pt100 A
5 n.c. n.c.
6 n.c. n.c.
7 Thermo+ Pt100 B
8 Thermo- Pt100 B Common

Baumer Electrical connection of the process display | 4
V1 | PA418 Operating Manual 9
Pin Strain gauge
1 Sensor supply -
2 n.c.
3 Sensor supply +5V / +10 V
4 n.c.
5 n.c.
6 n.c.
7 Input mV+
8 Input mV-
Control input (3)
Pin
1 Common
2 Tara*
3 Reset Tara*
4 Hold*
* Factory settings. Other functions can be assigned via configuration.
Relay output (4), optional
Pin Two relays
1 normally closed 1
2 Inverter 1
3 normally open 1
4 normally closed 2
5 Inverter 2
6 normally open 2
Pin Four relays
1 normally closed 1
2 normally closed 2
3 normally closed 3
4 normally closed 4
5 n.c.
6 Common
Analog output (5), optional
Pin
1 (-) 4...20mA / 0...10V
2 (-) 4...20mA / 0...10V

4 | Electrical connection of the process display Baumer
10 Operating Manual PA418 | V1
4.1 Connection examples
Input voltage
4-wire sensor, ex-
ternal supply
Display
V-
Sensor
V+ OUT+ OUT-
V IN+
IN-
ext. Sensor
supply -
+
87654321
3-wire sensor, ex-
ternal supply
V+ OUT+ OUT-
V IN+
IN-
+
87654321
-
Display Sensorext. Sensor
supply
4-wire sensor,
supplied by de-
vice
Display Sensor
V+ OUT+ OUT-
V IN+
IN-
87654321 V-
Sensor supply-
Sensor supply+
3-wire sensor,
supplied by de-
vice
Display Sensor
V+ OUT+ OUT-
V IN+
IN-
87654321
Sensor supply+
Input current
4-wire sensor, ex-
ternal supply
V-
V+ OUT+ OUT-
I IN+
IN-
-
+
87654321
Display Sensorext. Sensor
supply
3-wire sensor, ex-
ternal supply
V+ OUT+ OUT-
I IN+
IN-
+
87654321
Display Sensorext. Sensor
supply
2 Wire 4 ... 20 mA
sensor, external
supply
V+ OUT+ OUT-
I IN+
IN-
+
87654321
-
Display Sensorext. Sensor
supply
4-wire sensor,
supplied by de-
vice
Display Sensor
V+ OUT+ OUT-
I IN+
IN-
87654321 V-
Sensor supply-
Sensor supply+
Table des matières
Autres manuels Baumer Moniteur

Baumer
Baumer PA408 Manuel utilisateur

Baumer
Baumer PA210 Manuel utilisateur

Baumer
Baumer NE1218 Manuel utilisateur

Baumer
Baumer PA201 Manuel utilisateur

Baumer
Baumer N 152 Manuel utilisateur

Baumer
Baumer PCD41 PX01 Series Manuel utilisateur

Baumer
Baumer PA203 Manuel utilisateur

Baumer
Baumer PA220 Manuel utilisateur

Baumer
Baumer N153 Manuel utilisateur