Bathology Spectrum 510 Manuel utilisateur

BATHOLOGY
Spectrum 510
Color Bathing Experience
Installation and Operation Manual
rediscover bathing

2
Spectrum 510
ContentsContents
Installation ConsiderationsInstallation Considerations ---------------------------------------------
Installation - OverivewInstallation - Overivew --------------------------------------------------
Installation - DMX Driver / Power SupplyInstallation - DMX Driver / Power Supply ----------------------------
Installation - Touch InterfaceInstallation - Touch Interface ------------------------------------------
Installation - Brilliance Light FixtureInstallation - Brilliance Light Fixture -----------------------------------
OperationOperation ----------------------------------------------------------------
Product CareProduct Care -------------------------------------------------------------
Replacement PartsReplacement Parts -------------------------------------------------------
SpecificationsSpecifications ------------------------------------------------------------
TroubleshootingTroubleshooting ---------------------------------------------------------
NotesNotes ---------------------------------------------------------------------
33
44
55
77
1010
1414
1616
1616
1616
1818
2121

3
BATHOLOGY
by
Carefully review all
installation options and instructions
before proceeding.
For safety purposes, use
safety goggles at all times.
Before wiring to power
supply, turn off electricity at the fuse or
circuit breaker box.
Check for piping /
electrical before cutting or drilling.
Some electrical
components are not waterproof.
If there is any risk of
uninsulated electrical connections in
your wall / ceiling area, use insulating
gloves.
All wiring must be done in
accordance with National Electric Code
and local building code.
Prior to installation,
consider the placement carefully, taking
into account the location of electrical,
plumbing, and other fixtures.
Touch Interface can be
installed outside of a wet environment,
on a vertical wall, convenient for user
operation. It can be installed a dry
bathing environment 48” above the
floor maximum. It must also avoid
elements such as direct water and
steam emissions.
Installation ConsiderationsInstallation Considerations
Please read this manual in its entirely prior to installationPlease read this manual in its entirely prior to installation
! IMPORTANT
! IMPORTANT
! IMPORTANT

12
4
Spectrum 510
Installation - OverviewInstallation - Overview
Package Includes
Item Quantity Description
A 1 DMX Driver
B 1 Touch Interface
C 1 Power Supply, 12VDC
D 1 Power Supply Connector, 50’
E 1 DMX IN Cable, 50’
F 1 Cat6 Cable, 1’
Item Quantity Description
G 1 RJ-45 Splitter
H 1 Cat6 Cable, 25’
I 1 Brilliance 410 Light Fixture
J 1 16” Location Templates
K 1 DMX Power Supply, 48VDC
1Silicone Sealant, 1 oz tube
DMX Driver
Accessible, Dry Location Desired Interface
Location
Desired Light Locations
Touch Interface
16” Location
Templates
Cat6 Cable, 1’
RJ-45
Splitter
Cat6 Cable,
25’
Power Supply,
12VDC
Ground 120VAC, 15
Amp Duplex Outlet
NOTE: Do not install Touch Interface
inside wet environment.
NOTE: Both ends of splitter must be
used, if a splitter is used. Lights are in
series and will not illuminate if a Splitter
port is left open. Exclude Splitter and
Cat6 Cable, 1’ if only one light will be
used in a particular zone / port.
Power Supply
Connector, 50’
DMX IN
Cable, 50’
Brilliance 410
Light Fixture
A
B
J
F
G
H
C
D
E
I
DMX Power
Supply, 48VDC K
NOTE: It is recommended that all electrical
equipment be tested prior to installation.
NOTE: Do not hot swap any electrical
components. Fully disconnect system from
power source before swapping electrical
components.

1 2
1 2
5
BATHOLOGY
by
DMX Driver
DMX Power
Supply
Port 2
Port 3
48VDC
DMX Out
48VDC
DMX In
DMX First Power
Supply Input
DMX Second Power
Supply Input
120VAC Power In
Port 1
Port 4
DMX IN
DMX IN
AK
Installation for 1-24 Lights Dip Switches
Installation - DMX Driver / Power SupplyInstallation - DMX Driver / Power Supply
Brilliance lights run on 350mA. Ensure
that Dip switch 1 and 2 are both in the
down position at 350mA.
1 12 2
200mA
250mA
300mA
350mA
1. Determine best location for
DMX Driver (A) and DMX Power
Supply (K), making note of cord
lengths.
2. Using a screwdriver fully loosen
the 48VDC Output + and – on
power supply (K) and 48VDC
Input + and – on the DMX driver
(A).
3. Connect the Red wire to the +
Output on the power supply (K)
and the other end to the + Input
on the DMX driver (A).
4. Connect the Black wire to the -
Output on the power supply (K)
and the other end to the - Input
on the DMX driver (A).

1 2
6
Spectrum 510
Additional Power Supply for 25 - 48 Lights
Installation - DMX Driver / Power Supply (Continued)Installation - DMX Driver / Power Supply (Continued)
DMX Driver
DMX Power
Supply
Port 2
Port 3
48VDC
DMX Out
48VDC
DMX In
DMX Second Power
Supply Input
120VAC Power In
Port 1
Port 4
DMX IN
DMX IN
AK
1. Follow and complete installation
for 1-24 lights.
2. Mount power supply (K) next to
first power supply (K).
3. Using a screwdriver fully loosen
the 48VDC Output + and – on
power supply (K) and 48VDC
Input + and – on the DMX driver
(A).
4. Connect the Red wire to the +
Output on the power supply (K)
and the other end to the + Input
on the DMX driver (A).
5. Connect the Black wire to the -
Output (K) on the power supply
and the other end to the - Input
on the DMX driver (A).

7
BATHOLOGY
by
Touch Interface
Screwdriver
Loosen
Orange 4 Screw
Terminal Block
6 Screw
Terminal Block
Silicone after
wiring
Tape
B
Installation - Touch InterfaceInstallation - Touch Interface
1. Determine the desierd location
for the Touch Interface (B),
making note of the cord lenghts.
2. Cut a 1-1/2”W x 2-13/32” H
hole in desired location for the
Touch Interface (B).
3. Install a standard single gang
electrical box in an accessible
dry location.
4. Run a grounded 120VAC
from the power supply to
the accessible dry location’s
electrical box.
5. Run the DMX IN Cable (E) wires
and the Power Supply Connector
(D) wires to the Touch Interface’s
(B) hole cutout.
6. Remove orange 4 screw terminal
block and 7 screw terminal block
from respective pin terminals.
7. Using a screwdriver, fully loosen
the “GND”, “D-”, and “D+”
sections of the orange 4 screw
terminal, and “GND”, and “V in
+” of the 7 screw terminal.
8. Connect the DMX IN Cable (E)
GND to the “GND” orange 4
screw terminal block.
9. Connect the DMX IN Cable (E)
Red D- to the “D-” orange 4
screw terminal block.
10. Connect the DMX IN Cable (E)
Black + to the “D+” orange 4
screw terminal block.

8
Spectrum 510
11. Connect the Power Supply
Connector (D) White - to the
“GND” 7 screw terminal block.
12. Connect the Power Supply
Connector (D) Black + to the “V
in +” 7 screw terminal block.
13. Using a screw driver, tighten
the “GND”, “DMX -”, “DMX +”,
sections of the 4 screw terminal,
and “GND”, and “V in +” of the
7 screw terminal.
14. Insert orange 4 screw terminal
block and 7 screw terminal
block into their respective pin
terminals.
15. Remove DMX Driver’s (A) DMX
IN screw terminal block from pin
terminal.
16. Connect the DMX IN Cable (E)
Ground to the DMX Driver’s (A)
DMX IN screw terminal block’s
“GND”.
17. Connect the DMX IN Cable (E)
Red to the DMX Driver’s (A) DMX
IN screw terminal block’s “D-”.
18. Connect the DMX IN Cable (E)
Black to the DMX Driver’s (A)
DMX IN screw terminal block’s
“D+”.
19. Using a screwdriver, tighten the
“GND”, “D-”, and “D+” sections
of the DMX IN screw terminal
block.
20. Insert DMX IN screw terminal
block into its pin terminal.
Installation - Touch Interface (Continued)Installation - Touch Interface (Continued)
21. Test light system prior to
mounting Touch Interface (B)
to wall. Verify connections are
secure and working properly.
22. Apply a 1/8” bead of silicone
around the back of the Touch
Interface (B).
23. Peel off tape and mount Touch
Interface (B) to hole cutout area.
24. Apply a 1/8” of silicone around
the edge of the mounted Touch
Interface (B) as required to form
a water tight seal.
25. Allow silicone to cure for 24
hours before exposing product
to any source of moisture.

9
BATHOLOGY
by
Installation - Touch Interface (Continued)Installation - Touch Interface (Continued)
Touch Interface
DMX Out
Screw Terminal (Orange)
Power In
Screw Terminal
GND V+
V in +
GND
D+ R
D+ G
B
D- W
Black D+
Black +
Black D+D+
GroundGND
Red D-
White -
Red D-D-
Power Supply
Connector, 50’
DMX IN
Cable, 50’
B
D
E
Ground

10
Spectrum 510
Installation - Brilliance Light FixturesInstallation - Brilliance Light Fixtures
1. Determine number of lights per
port. Limit 12 lights per port.
2. Construct light assembly using
the diagrams on the next page.
3. Repeat steps 1 and 2 for
additional zones.
4. Determine desired Brilliance
Light Fixture (I) location.
Warning:Warning: The Splitters (G) should be
kept in an accessible location when
installed. Only use the Splitters (G)
when assembling the Brilliance Light
Fixtures (I) and ocmponents of this kit.
Important:Important: Driver has 4 ports. Each
port operates 1212 lights max. Take this
into consideration when planning light
installation.
RJ-45
Splitter
IN
OUT
IN Supports:
- Cable, 1’ (F)
(Comes from DMX Driver)
OUT Supports:
- Cable, 1’ (F)
- Cable, 25’ (H)
(Goes toward Lights)
G
Table des matières
Autres manuels Bathology Équipement d'éclairage

Bathology
Bathology Spectrum 321 Manuel utilisateur

Bathology
Bathology Spectrum 620-C Manuel utilisateur

Bathology
Bathology Spectrum 441 Manuel utilisateur

Bathology
Bathology Spectrum 620-W Manuel utilisateur

Bathology
Bathology Spectrum 441D Manuel utilisateur

Bathology
Bathology Spectrum 350 Manuel utilisateur

Bathology
Bathology Spectrum 440 Manuel utilisateur
Manuels Équipement d'éclairage populaires d'autres marques

Qazqa
Qazqa Suplux SL 3 Black 103062 Manuel utilisateur

Commercial Electric
Commercial Electric 54568141 Manuel utilisateur

CREE LIGHTING
CREE LIGHTING 304 Series Manuel utilisateur

Goobay
Goobay 49867 Manuel utilisateur

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manuel utilisateur

Alkalite
Alkalite Krypton KT-81 Manuel utilisateur