Remark: The Remote Control can also be configured for a „No Echo“ mode. In this mode the Remote Control is working like
a „traditional remote control“ and no reply from the modules is expected. Using the „No Echo“ mode only makes sense if
several Chromoflex RC modules are operated without a „Master“ in one network.
Technical Data
Radio frequency: 868.3 Mhz (license free in EC Switzerland Norway and Iceland)
Batteries: 2 batteries type „Lady“ /„LR03“ /„AAA“ with 1.5 Volt (Alkaline)
Contact / Internet
Download of the PC Software manuals data sheets and technical requests (technical requests only as E-mail please!):
www.chromoflex.com , www.barthelme.de
Manufacturing and distribution:
www.barthelme.de
Setup of the Remote Control
In the setup mode (pressing SHIFT for > 4 sec) a 5-digit code must be entered using the buttons COL+ and Col-. Please
press the buttons COL+ / COL- according to the following table. We recommend to use the modes with „Echo“. Only if
several modules are operated without a „Master“ in one network the mode „No Echo“ makes sense. The factory setup is
„Network 8 Echo“:
No: Code Col+/- Explanation
0: - - - - - No Echo, Normal (Any module), Net 1
1: - - - - + No Echo, Normal (Any module), Net 2
2: - - - + - No Echo, Normal (Any module), Net 3
3: - - - + + No Echo, Normal (Any module), Net 4
4: - - + - - No Echo, Normal (Any module), Net 5
5: - - + - + No Echo, Normal (Any module), Net 6
6: - - + + - No Echo, Normal (Any module), Net 7
7: - - + + + No Echo, Normal (Any module), Net 8
8: - + - - - No Echo, Only master, Net 1
9: - + - - + No Echo, Only master, Net 2
10: - + - + - No Echo, Only master, Net 3
11: - + - + + No Echo, Only master, Net 4
12: - + + - - No Echo, Only master, Net 5
13: - + + - + No Echo, Only master, Net 6
14: - + + + - No Echo, Only master, Net 7
15: - + + + + No Echo, Only master, Net 8
16: + - - - - Echo, Normal (Any module), Net 1
17: + - - - + Echo, Normal (Any module), Net 2
18: + - - + - Echo, Normal (Any module), Net 3
19: + - - + + Echo, Normal (Any module), Net 4
20: + - + - - Echo, Normal (Any module), Net 5
21: + - + - + Echo, Normal (Any module), Net 6
22: + - + + - Echo, Normal (Any module), Net 7
23: + - + + + Echo, Normal (Any module), Net 8 (** Factory Default **)
24: + + - - - Echo, Only master, Net 1
25: + + - - + Echo, Only master, Net 2
26: + + - + - Echo, Only master, Net 3
27: + + - + + Echo, Only master, Net 4
28: + + + - - Echo, Only master, Net 5
39: + + + - + Echo, Only master, Net 6
30: + + + + - Echo, Only master, Net 7
31: + + + + + Echo, Only master, Net 8
CHROMOFLEX RC - Radio Remote Control - Manual - English V1.01 - www.barthelme.de Rev 15.03.2008