OmniCare EVC System
Installation & Commissioning Manual
Manual name: OmniCare
Issue: 1
ECR: 2008
Date of issue: October 2007

OmniCare EVC System
Installation & Commissioning Manual
ii OmniCare issue 1
C
O
M
M
U
N
I
C
A
T
I
O
N
S
© October 2007 Baldwin Boxall Communications Limited
Wealden Industrial Estate
Farningham Road, Jarvis Brook
Crowborough
East Sussex
TN6 2JR
UK
Telephone: +44 (0)1892 664422
Facsimile: +44 (0)1892 663146
Email: [email protected].uk
Website: http://www.baldwinboxall.co.uk
This equipment has been designed and manufactured to conform to the following
EC Standards:
EMC: EN55103-1 Environment Classification: E1,
EMC: EN55103-2 Environment Classification: E5,
Safety: EN60065
Failure to use the equipment in the manner described in the product literature
will invalidate the conformity.
A “Declaration of Conformity” statement to the above standards and a list of
auxiliary equipment used for compliance verification is available on request.

OmniCare EVC System
Installation & Commissioning Manual
OmniCare issue 1 iii
C
O
M
M
U
N
I
C
A
T
I
O
N
S
Amendment Record __________________________________ vii
Proprietary Notice ___________________________________ vii
Safety Information ___________________________________viii
Comments_________________________________________viii
Technical Description
Description _________________________________________1
Technical Specifications_________________________________2
Control Panels- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2
Disabled Refuge Remote Unit (BVOCECP)- - - - - - - - - - - - - - - - 3
Advance Disabled Refuge Remote (BVOCA) - - - - - - - - - - - - - - - 4
Fire Telephone Remote Unit (BVFHL) - - - - - - - - - - - - - - - - - - 5
Combined Disabled Refuge / Fire Telephone (BVOCRFC) - - - - - - - - - 6
Disabled Toilet Alarm (BVOCDTA) - - - - - - - - - - - - - - - - - - - 7
Control Panel LEDs & Switches___________________________8
Zone Select Button & Status LEDs- - - - - - - - - - - - - - - - - - - - 8
System Status & Fault LEDs - - - - - - - - - - - - - - - - - - - - - - - 9
“All Call” and “Speak” Buttons - - - - - - - - - - - - - - - - - - - - 10
Handset “Speak” Button - - - - - - - - - - - - - - - - - - - - - - - 10
Overview of System Design Requirements
System Layout ______________________________________ 11
Using Slave Control Panels _____________________________ 12
Cable Selection _____________________________________ 13
Cabling Instructions __________________________________ 13
Installation Examples__________________________________ 14
Connection Details - up to 16 Remotes - - - - - - - - - - - - - - - - 14
Connection Details - up to 32 Remotes - - - - - - - - - - - - - - - - 15
Connection Details - up to 48 Remotes - - - - - - - - - - - - - - - - 16
Connection Details - up to 64 Remotes - - - - - - - - - - - - - - - - 17
Complex Configuration Example - - - - - - - - - - - - - - - - - - - 18
Hardware Installation
Tools Required _____________________________________ 19
Installing the Remote Units _____________________________ 20

OmniCare EVC System
Installation & Commissioning Manual
iv OmniCare issue 1
C
O
M
M
U
N
I
C
A
T
I
O
N
S
Disabled Refuge Remotes (BVOCECP)- - - - - - - - - - - - - - - - - 20
Advance Refuge Remotes (BVOCA) - - - - - - - - - - - - - - - - - - 24
Fire Telephone Remotes (BVFHL) - - - - - - - - - - - - - - - - - - - 28
Combined Remotes (BVOCRFC) - - - - - - - - - - - - - - - - - - - 32
Disabled Toilet Alarm (BVOCDTA) - - - - - - - - - - - - - - - - - - 36
Installing the Control Panel(s) __________________________ 39
Minicare Control Panels (8, 16, and 32 zone) - - - - - - - - - - - - - - 39
48 and 64 Zone Control Panels - - - - - - - - - - - - - - - - - - - - 41
80 - 128 Zone Control Panels- - - - - - - - - - - - - - - - - - - - - 43
Connecting the Fire Panel Interface - - - - - - - - - - - - - - - - - - 44
Testing & Commissioning
Overview of the Commissioning Procedure ________________ 47
Tools Required _____________________________________ 48
Initial Cabling Checks_________________________________ 48
Commissioning Procedure _____________________________ 49
Testing Loop Integrity (Power Cables) - - - - - - - - - - - - - - - - - 49
Testing Loop Integrity (Data Cables)- - - - - - - - - - - - - - - - - - 50
Connecting Batteries - - - - - - - - - - - - - - - - - - - - - - - - - 54
Functional Testing Remote Units ________________________ 55
Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 55
Disabled Refuge Remote (BVOCECP) - - - - - - - - - - - - - - - - - 55
Advance Refuge Remote (BVOCA) - - - - - - - - - - - - - - - - - - 56
Fire Telephone Remote Units (BVFHL) - - - - - - - - - - - - - - - - 57
Combined Remotes (BVOCRFC) - - - - - - - - - - - - - - - - - - - 58
Disabled Toilet Alarm (BVOCDTA) - - - - - - - - - - - - - - - - - - 58
Control Panel Settings ________________________________ 59
Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 59
Zone Address Settings (JP1, JP2, JP3 PC1233)- - - - - - - - - - - - - - 59
Setting the Offset and Range & defining the “Master” Switch Panel - - - - 60
Fault Relay Operation (JP2 PC1234) - - - - - - - - - - - - - - - - - - 62
Zone Insert Labels___________________________________ 63
Tone Configuration Options
Introduction _______________________________________ 65
Overview of the Tone Generation Software ________________ 66
Configuring Remote Units _____________________________ 67

OmniCare EVC System
Installation & Commissioning Manual
OmniCare issue 1 v
C
O
M
M
U
N
I
C
A
T
I
O
N
S
Re-addressing Remote Units ____________________________ 67
Fault Finding
Fault Finding Remote Units during Commissioning - Overview ___ 69
Description of 0V Continuity Check - - - - - - - - - - - - - - - - - - 70
Check Terminations on Remote Units - - - - - - - - - - - - - - - - - 70
Description of Loop Integrity Check (Power Cables) - - - - - - - - - - 71
Testing Loop Integrity (Data Cables) & Diagnosing Fault Location - - - - 72
Fault Finding Procedures for Remote Units _________________ 73
Perform a 0V Continuity Check - - - - - - - - - - - - - - - - - - - - 73
Check Terminations on Remote Units - - - - - - - - - - - - - - - - - 73
Test the Loop Integrity (Power Cables) - - - - - - - - - - - - - - - - 74
Diagnosing the Location of Fault(s) using Commissioning Process - - - - 75
Diagnosing the Location of Fault(s) using the “System OK” LEDs- - - - - 78
Remote Units not found when Cabling appears Correct - - - - - - - - - 79
System Reset and System Configuration - - - - - - - - - - - - - - - - 79
Fault Finding - Normal Operation ________________________ 80
Remote Unit Fault Indication - - - - - - - - - - - - - - - - - - - - - 80
System Fault LEDs - - - - - - - - - - - - - - - - - - - - - - - - - - 81
“SYSTEM OK” Indicators on Remote Units - - - - - - - - - - - - - - 81
Fault Finding - Battery Charger __________________________ 82
Battery Charger Normal Operation - - - - - - - - - - - - - - - - - - 82
Battery Condition Monitoring- - - - - - - - - - - - - - - - - - - - - 83
Maintenance
Appointment of a “Responsible Person” ___________________ 85
Routine Testing _____________________________________ 86
Daily Check - Fault Indicators - - - - - - - - - - - - - - - - - - - - - 86
Weekly Functional Test - - - - - - - - - - - - - - - - - - - - - - - 86
Six Monthly Inspection by a “Competent Person”- - - - - - - - - - - - 86
Addendum
Maximum Cable Lengths and Resistance values ______________ 87
Approximate Cable Length Calculations____________________ 88
Distance Between Two Remote Units - - - - - - - - - - - - - - - - - 88
Readings with Local Unit Disconnected - - - - - - - - - - - - - - - - 89

OmniCare EVC System
Installation & Commissioning Manual
vi OmniCare issue 1
C
O
M
M
U
N
I
C
A
T
I
O
N
S
Resistance Readings when using Repeaters - - - - - - - - - - - - - - - 89
How to Calculate Cable Length _________________________ 90

OmniCare EVC System
Installation & Commissioning Manual
OmniCare issue 1 vii
C
O
M
M
U
N
I
C
A
T
I
O
N
S
AMENDMENT RECORD
PROPRIETARY NOTICE
All data and information contained within this manual is of a
proprietary nature with the exclusive title to the same held by
Baldwin Boxall Communications Limited. The possession of this
manual and the use of the information is, therefore, restricted
only to those persons duly authorised by Baldwin Boxall
Communications Limited.
Do not reproduce, transcribe, store in a retrieval system or
translate into any language, any part of this manual without the
prior permission of Baldwin Boxall Communications Limited.
In the interest of continual product development, Baldwin Boxall
Communications Limited reserves the right to make changes to
product specification without notice or liability. Use of Baldwin
Boxall Communications Limited products as critical components
in life support systems is not authorised except with express
written approval from Baldwin Boxall Communications Limited.
Page Number(s)
Affected
Change Note
Number
Nature of Amendment Date of
Amendment
All N/A Initial Release Spetember 2007

OmniCare EVC System
Installation & Commissioning Manual
viii OmniCare issue 1
C
O
M
M
U
N
I
C
A
T
I
O
N
S
SAFETY INFORMATION
Personnel who install, maintain or repair this equipment must
read the safety information below before starting work.
Voltages in excess of 30 Volts RMS or 50 Volts DC are considered
Hazardous and in certain circumstances can be lethal.
If Functional Testing, Maintenance, or Repair is to be completed
with the Mains Power (and/or battery backup) connected then
this should only be undertaken by personnel who are fully aware
of the danger involved and who have taken adequate precautions
and training.
This Manual contains Warnings, Cautions and Notes.
Warnings describe potential threats to health or life, e.g.
Cautions describe potential threats to the equipment, e.g.
Notes are statements that are useful to the user in the context of
a particular section of the manual, e.g.
COMMENTS
Comments regarding the content of this manual are welcome and
should be addressed to mail@baldwinboxall.co.uk.
!
WA R N I N G
Before attempting to remove this component, ensure the Mains
Power Supply and Battery Backup have been disconnected.
CAUTION
Notice must be taken of all cautions.
If a Caution is ignored the equipment may be damaged.
CAUTION: EL E C T R O -S T A T I C SENSITIVE DE V I C E S
Observe the relevant precautions for the protection of Electro-
static Sensitive Devices when handling this equipment.
NOTE: This is an example of a note.

OmniCare EVC System
Installation & Commissioning Manual
OmniCare issue 1 1
C
O
M
M
U
N
I
C
A
T
I
O
N
S
1 Technical Description
1.1 DESCRIPTION
The OmniCare EVC System is a fully addressable Emergency
Voice Communication System that allows Disabled Refuge, Fire
Telephones, and Disabled Toilet Alarm Remote Units to be
connected to just one system. It has been developed in
accordance with BS5588, BS5839 part 9 and BS8300:2001 (for
the Disabled Toilet Alarm).
The system has two main components - the Master Control Panel
and the Remote Units. The Remote Units are supplied in four
different styles to suit any installation.

OmniCare EVC System
Installation & Commissioning Manual
2OmniCare issue 1
C
O
M
M
U
N
I
C
A
T
I
O
N
S
1.2 TECHNICAL SPECIFICATIONS
1.2.1 Control Panels
Figure 1.1 — Typical OmniCare Control Panel
Control Panels
System self-monitoring BS5588 & BS5839 compliant
Remote signalling of fault Volt-free contact, closing/opening set on installation
Indicators Occupied, call, fault, power, charger, speech level
Transmission capability Half-duplex (DRS remotes) either voice switched or by
PTT (controlled at the Control Panel).
Full Duplex (Fire Telephones)
Power supply 110V / 230V AC autoswitching, battery backed with built
in batteries & charger
Power consumption (VA) 10VA + 1VA per remote connected
Dimensions (W x H x D) 410mm x 290mm x 200mm (8-32 way)
410mm x 455mm x 200mm (16-64 way)
410mm x 777mm x 200mm (80-128 way)
Bezel dimensions: 461mm x 506mm x 25mm.
Bezel cut out dimensions: 420mm x 465mm.
Bezel dimensions (W x H x D) 461mm x 340mm x 25mm (8-32 way)
461mm x 506mm x 25mm (16-64 way)
Bezel Cutout dimensions W x H 420mm x 300mm (8-32 way)
420mm x 465mm (16-64 way)
Knockouts 20mm diameter in top and top/rear
Security Lockable glazed door
Weight, including batteries 21kg upto 32way, 26kg upto 64way, 37kg upto 128way
Temperature Range -10 to +30°C (storage and operating)
Humidity Range 95% Non Condensing
Table des matières
Manuels Système de conférence populaires d'autres marques

Kramer
Kramer VIA GO Manuel utilisateur

AVT
AVT MAGIC AC1 Go Manuel utilisateur

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Manuel utilisateur

Sony
Sony PCS-I150 Manuel utilisateur

Middle Atlantic Products
Middle Atlantic Products VTC Series Manuel utilisateur

Prentke Romich Company
Prentke Romich Company Vanguard Plus Mode d’emploi