Balance KH 5509 Manuel utilisateur

Kompernaß GmbH
Burgstraße
D– Bochum
Deutschland/Germany
—
www.kompernass.com
--
v..
KH /
UK
IB KH5509-10 UK.indb 1IB KH5509-10 UK.indb 1 09.01.2006 16:10:26 Uhr09.01.2006 16:10:26 Uhr

Body fat, muscle mass and
water analysis scales
Instructions for use
KH 5509
KH 5510
IB KH5509-10 UK.indb 2IB KH5509-10 UK.indb 2 09.01.2006 16:10:32 Uhr09.01.2006 16:10:32 Uhr

IB KH5509-10 UK.indb 3IB KH5509-10 UK.indb 3 09.01.2006 16:11:44 Uhr09.01.2006 16:11:44 Uhr

w
er
q
t
y
i
a
oo
1!
u
i
oo
a
t
y
w
er
q
1!
u
KH 5509
KH 5510
IB KH5509-10 UK.indb 4IB KH5509-10 UK.indb 4 09.01.2006 16:11:45 Uhr09.01.2006 16:11:45 Uhr

IB KH5509-10 UK.indb 5IB KH5509-10 UK.indb 5 09.01.2006 16:12:24 Uhr09.01.2006 16:12:24 Uhr

IB KH5509-10 UK.indb 6IB KH5509-10 UK.indb 6 09.01.2006 16:12:24 Uhr09.01.2006 16:12:24 Uhr

3
Index
1. Safety instructions.................................................................................................................4
2. Usage ......................................................................................................................................5
3. Technical data........................................................................................................................5
4. Scope of delivery....................................................................................................................6
5. Components and operating elements ...................................................................................6
5.1. Display remote control unit.........................................................................................................6
5.2. Scales...............................................................................................................................................6
6. Preparing the scales for use...................................................................................................7
6.1. Unpacking the components.........................................................................................................7
6.2. Inserting the batteries in the scales.............................................................................................7
6.3. Inserting batteries in the display remote control unit..............................................................7
7. Selecting a suitable location ..................................................................................................7
8. Prior to initial use..................................................................................................................8
9. Using the scales......................................................................................................................9
9.1. Measuring body weight only .......................................................................................................9
9.2. Measuring body weight, body fat, muscle mass and body water percentages as well as
caloric requirement ............................................................................................................................10
9.2.1. Important notes on measuring...........................................................................................10
9.3. Comparison of current and previous measurements ............................................................13
9.4. Display previous measurement results.....................................................................................13
9.5. Using the guest mode..................................................................................................................14
10. Maintaining the scales.......................................................................................................15
10.1. Replacing the batteries in the scales .......................................................................................15
10.2. Replacing the batteries of the display remote control unit .................................................15
11. Troubleshooting/error messages....................................................................................... 15
11.1. e scales can not be turned on .............................................................................................15
11.2. e display remote control unit can not be turned on.........................................................15
11.3. e display screen is not functioning properly.....................................................................16
11.4. Error messages appear on the display screen ........................................................................16
11.4.1. “0-Ld”...................................................................................................................................16
11.4.2. “Err” .....................................................................................................................................16
11.4.3. “––––”..................................................................................................................................16
11.5. Measurement results seem unrealistic....................................................................................17
11.6. Other malfunctions...................................................................................................................17
12. Cleaning the scales ............................................................................................................ 18
13. Storing the scales ...............................................................................................................18
14. Disposing of the scales ......................................................................................................18
IB KH5509-10 UK.indb EN3IB KH5509-10 UK.indb EN3 09.01.2006 16:12:24 Uhr09.01.2006 16:12:24 Uhr

4
ôNote:
For the sake of simplicity, the body fat, muscle
mass and water analysis scales will be called
“scales” throughout these instructions for use.
1. Safety instructions
†Danger!
Under no circumstances should you use the
scales if you use a pacemaker, a respirator, an
electrocardiograph or similar medical device!
Use of the scales could prevent proper func-
tioning of these devices! is could cause risk
of death! If you are not sure whether or not
you are allowed to use the scales: please con-
sult your physician prior to use!
If you desire to reduce your body weight due
to overweight or increase it due to under-
weight, you should always consult a doctor.
Every treatment and diet should be only in
reference to a doctor. Recommendations for
diets or tness programmes on the basis of the
determined values should be given by a doctor
or other qualied person. Do not attempt to
interpret the data yourself.
Please make sure no water or moisture can
enter the scales or display remote control unit.
Otherwise the scales and display remote con-
trol unit can be damaged beyond repair. is
could also cause danger of electric shock!
|Warning!
Do not place the scales and display remote
control unit in the immediate vicinity of heat
sources such as ovens, heaters and other simi-
lar devices. Otherwise the scales and display
remote control unit can be damaged beyond
repair. e scales and display remote control
unit can only be operated at temperatures be-
tween ° and ° Celsius. e scales should
be kept within this temperature range even
while not being used. Temperatures outside
of this range can result in malfunctioning or
long-term damages.
Do not place a load of more than kilo-
grams on the scales! Otherwise the scales
could be damaged beyond repair!
e scales and the display remote control unit
contain no user-serviceable parts. e war-
ranty is void if the casings of the scales and/or
display remote control unit are opened! For
repairs, please contact our service partner
nearest you. You will nd the addresses of our
service partners on the warranty card. You
will nd the warranty card with the scales.
™Careful!
Battery acid could leak out, especially if the
batteries are old. erefore you should re-
move all batteries if you do not plan to use the
scales and remote control unit for long periods
of time. is protects the scales and display
remote control unit from damages resulting
from battery acid leakage.
ôNote:
Avoid static charge or discharge because this
could result in display errors or sudden switch-
ing o of the scales.
No liability will be taken and no guarantee
will be made for damages …
Úresulting from opening the casings of
scales and/or display remote control unit
Úresulting from repair attempts not made
by qualied experts
Úresulting from using the scales and/or dis-
play remote control unit for purposes oth-
er than intended
IB KH5509-10 UK.indb EN4IB KH5509-10 UK.indb EN4 09.01.2006 16:12:24 Uhr09.01.2006 16:12:24 Uhr

5
2. Usage
e body fat, muscle mass and water analysis
scales Balance KH /KH are intended
exclusively for …
Úmeasuring body weight, body fat, muscle
mass and body water of people from sev-
en years of age and a height of at least
centimeters
Úmeasuring the approximate daily caloric
requirements
Únon-commercial use in private households.
e body fat, muscle mass and water analysis
scales Balance KH /KH are not in-
tended for use by those using medical devices
including but not limited to …
Úpacemakers
Úrespirators or
Úelectrocardiographs.
e body fat, muscle mass and water analysis
scales Balance KH/KH are not con-
strued for professional use in hospitals or
other medical facilities.
ôNote:
No liability will be assumed and no warranty
granted for damages resulting from use of the
scales and/or display remote control unit for
purposes other than intended!
3. Technical data
ÚPower supply, scales: × . V AA
ÚPower supply, display remote control
unit: × .V AAA
ÚMaximum load/maximum measurable
weight: kg/ lb
ÚMinimum measurable weight: kg/. lb
ÚTolerance < kg: max. g
Tolerance > kg: % +/- , kg
ÚMeasuring procedure: bioelectrical imped-
ance analysis via four foot sensors
ÚIncrements for weight measurement:
. kg/. lb
ÚFat percentage measurement: – %
ÚIncrements for fat percentage measure-
ment: , %
ÚWater percentage measurement: – %
Ú
Increments for water percentage measure-
ment: , %
ÚMuscle mass percentage measurement:
– %
ÚIncrements for muscle mass percentage
measurement: , %
ÚCaloric requirements display: in kcal
ÚIncrements for caloric requirements dis-
play: kcal
ÚHeight entry range: - cm/'"–'"
ÚAge entry range: – years
Ú memory locations for personal data
ÚFunctions: Weight measurement only/
weight, body fat percentage, muscle mass
percentage and body water percentage
measurement/measurement of approxi-
mate daily caloric requirement/display of
approximate tness level
ÚMeasuring units adjustable: kg/lb, cm/
inches
ÚBattery status indicator
ÚOverload indicator
ÚError indicator
ÚAutomatic shuto of scales: aer seconds
ÚAutomatic shuto of display remote con-
trol unit: aer seconds
IB KH5509-10 UK.indb EN5IB KH5509-10 UK.indb EN5 09.01.2006 16:12:25 Uhr09.01.2006 16:12:25 Uhr

6
5. Components and
operating elements
.. Display remote control unit
qButton (Down)
wButton
eButton (On/O)
rButton (Up)
tBattery compartment
yInfrared receiver
u Wall Holder for the Display
remote control unit
.. Scales
iScales on/o indicator
oSensors
aBattery compartment
1! Holder for display remote control unit
ÚOperating temperature: ° C–° C
4. Scope of delivery
' Body fat, muscle mass and water analysis
scales
' Display remote control unit
' AA/Mignon type batteries for scales
' AAA/Micro type batteries for display
remote control unit
' double-sided adhesive tape, screws and
rawl plugs for wall mounting of display
remote control unit
' Wall Holder for the Display
remote control unit
' Accompanying informational material
' ese instructions for use
IB KH5509-10 UK.indb EN6IB KH5509-10 UK.indb EN6 09.01.2006 16:12:25 Uhr09.01.2006 16:12:25 Uhr
Table des matières
Autres manuels Balance Échelle

Balance
Balance KH 391 Guide rapide

Balance
Balance KH 5522 Manuel utilisateur

Balance
Balance KH 390 Guide rapide

Balance
Balance Living Precision LIFE TRACK 10500 Manuel utilisateur

Balance
Balance KH 5514 Manuel utilisateur

Balance
Balance KH 5514 Manuel utilisateur

Balance
Balance KH 5503 Manuel utilisateur

Balance
Balance Balance KH 5506 Guide rapide

















