Auvon AS8012 Manuel utilisateur

USER MANUAL
Model AS8012
Dual Channel TENS Massager
Relaxation, Anywhere, Anytime
Device Name: TENS and Powered Muscle Stimulator

1
INCLUDED IN THIS STANDARD
PACKAGE
● AUVON®Dual Channel TENS Massager
● SquarePinPads
●RectanglePinPads
●PadsHolder
●Pouch
●SetofLeadWires(½Wire)
●USBCable&USBAdapter
●UserManual
●HappyCard
FEATURES
● 2outputwith20modes
● 20levelintensity
● 20minutesdefaulttimer,canadjustablefrom
10-60minutes
● Rechargeablelithiumbattery
● Batteryindicatortoknowwhenneedto
rechargebattery
● ACadapter110-240V,USBCharger5V
SAFETY PRECAUTIONS AND
WARNINGS
DO NOT USE THIS UNIT UNDER
THESE CONDITIONS

2
Consultwithyourphysicianbeforeusingthisunit.
Theunitmaycauselethalrhythmdisturbances
incertainsusceptibleindividuals.Ifyouhave
hadarecentsurgicalprocedure,thestimulation
maydisruptthehealingprocess.
Beforeusingyourunit,inspectthesethings.
1.Cordisnotbroken.
2.Padgelisnotdamaged.
3.Electrodecordconnectionisnotbroken.
4.Unitisintactandworking.
5.Thereisnobatteryleakage.
DO NOT USE ON THESE INDIVIDUALS
● Pregnantwomen
● Donotuseonchildrenorinfantsbecause
thedevicehasnotbeenevaluatedforpediatric
use
● Keepoutofthereachofyoungchildren
becausetheelectrodecordcouldcause
strangulation
● Personsincapableofexpressingtheir
thoughtsorintentions.
● Personsincapableofoperatingtheunitby
themslelves.
● Usewithcautionifyouhaveatendencyto
bleedinternally,suchasfollowinganinjuryor

3
fracture.
● Ifyouhavesuspectedordiagnosedheart
disease,youshouldfollowprecautions
recommendedbyyourphysician.
● Ifyouhavesuspectedordignosedepilepsy,you
shouldfollowprecautionsrecommendedbyyour
physician
● Usecautionifstimulationisappliedoverthe
menstruatinguterus.
NEVER APPLY THE PADS TO THESE
BODY AREAS:
● Thehead,themouth,oranyareaofthe
face.
● Theneckoranyareaofthethroatbecause
thiscouldcauseseveremusclespasms
resultinginclosureoftheairway,difficultyin
breathing,oradverseeffectsonheartrhythmor
bloodpressure.
● Donotuseneartheheart,orongenitalarea.
● Bothsidesofthethoraxsimultaneously
(lateralorfrontandback),oracrossyourchest
becausetheintroductionofelectricalcurrent
maycauserhythmdisturbanceswhichcouldbe
lethal.
● Onthecalvesofbothlegsatthesametime

4
becausethismaycausecardiacdisturbance.
● Onthebottomofbothfeetatthesametime
becausethismaycausecardiacdisturbance.
Openwoundsorrashesoroverswollen,
red,infectedorinflamedareasorskin
eruptions(suchasvaricoseveins,phlebitis,
thrombophlebitisandthrombosis),orontopof
orclosetocancerouslesions,oroverareasof
skinthatlacknormalsensation.
DO NOT USE THIS UNIT DURING
THESE ACTIVITIES
● Wheninbathorshower;
● Whilesleeping;
● Whiledriving,operatingmachinery,orduring
any activity in which electrical stimulation can
putyouatriskofinjury.
PAIN MANAGEMENT WARNINGS
● Ifyouhavehadmedicalorphysical
treatmentforyourpain,consultwithyour
physicianbeforeusingthisunit.
● Ifyourpaindoesnotimprove,becomes
seriouschronicorsevere,orcontinuesformore
thanfiveyears,stopusingtheunitandconsult
withyourphysician.
● Themereexistenceofpainfunctionsasa

5
veryimportantwarningtellingusthatsomething
iswrong.Therefore,ifyousufferfromany
seriousillness,consultyourphysicianinorder
toconfirmthatitisadvisableforyoutousethis
PowerReliefunit.
PRECAUTIONS REGARDING THE PADS
● Donotmovethepadstoanotherlocation
whiletheunitison.
● Therapywon'tworkwithjustonepad.You
MUSTUSETWOPADSatthesametime.
● Makesurethecomponentsareconnected
wellandthepadsarefixedonthepartofthe
bodyyouwishtotreatorthetherapymaynot
beeffective.
● Padshouldnottouchanymetalobject,such
asbeltbuckle,necklace,orothermetalworn
underclothing.
● Donotoverlappadsorputpadsontopof
eachother.Itmayweakenorstoptherapy,or
theunitmaystopworking.Gelpadsmayalso
sticktogetherandcausegeltoberemoved
whenseparating.
● Donotsharepadswithanotherperson.This
maycauseaskinirritationorinfection.Pads
areintendedforusebyoneperson.

6
● Donotleavepadsattachedtotheskinafter
treatment.
● Donotbendorfoldbecausethegelmayget
damagedanditwon'tstickorfunctionproperly.
● Toavoiddamagetotheadhesivesurface
tothepads,putthepadsonlyontheskinor
ontheplasticpadholderprovidedtoavoid
damagetotheadhesivesurfaceofthepads.
● Alwaysplacecleanpadsinaccordancewith
illustrationsprovided.
● Donotapplyointmentoranysolventto
thepadsortoyourskinbecauseitwilldisrupt
thepadsfromfunctioningproperly.Theself-
adhesivepadswilladheretoyourskin.
HOW DOES IT WORK?
Scientifictheorysuggeststhatelectrical
stimulationtherapymayworkinseveralways:
1. Thegentleelectricalpulsemovethroughthe
skintonearlynervestoblockorshutoutthepain
messagefromthesourceofthepaintoreaching
thebrain.
2. Thegentleelectricalpulseincreasesthe
productionofthebody'snaturalpainkiller,such
asendorphins.
3. Furthermore,itisthoughtthattheelectrical
stimulationimprovesbloodcirculationaswell.

7
Musclescontractandrelaxwiththeflowof
theelectricalstimulation.Withthereplated
contractingandrelaxing,thebloodflowsinand
outandthebloodcirculationimproved.
OPERATING INSTRUCTIONS
HOW TO USE
1.Cleanyourskinbeforeuse.Usethepadson
cleanandflatareas,nosweat,nooil.
2.Attachonepairortwopairsoftheelectrode
padstothemassagerarea,suchasshoulder
andleg.
Note:Addingafewdropsofwateronthepads
anddryingthepadsnaturallywillincreasetheir
longevity.Makesurebothpadsontheskinand
notoverlapping.
3.Connectapairofelectrodepadstoonelead
wirebyplugthemon;theotherendofthewire
isconnectedtotheleftoutputofthedevice.
Similarly,theotherpairofelectrodepadsis
connected to the remaining wire end and the
rightoutputofthedevice.
4.Turnonthedevicebyslidingtheon/off
switchonthetopoftheunit.
5.PresstheAbuttontochooseChannelA.

8
PresstheMbuttontotrydifferentmodeand
press+/-toincreaseordecreaseintensity.
PresstheBbuttontochooseChannelBand
selectyourfavoritemodeandintensity(The
modesonChannelAcanbedifferentwiththat
onChannelB).
Note:Rememberthestrengthwilldefaulttothe
lowestsettingbyeachmodeselection.
6.Recommendedapplicationis10-60
minutes.Increase10minutesbyeachsetting
bypressingtheTonthedevice.Thetime
remaining is automatically counted down until it
turnsoffoncethetimefinishes.
7.Pressandholdthecenterbuttonfor3
secondstolockthescreen,3secondsagainto
unlockthescreen.
AFTER USE
1.Turnoffthedeviceonbyslidingtheon/off
switchonthetopoftheunit.
2.Removeleadwirepinfromelectrode
connectorbygentlytwistingandpullingitout.
3.Liftacorneroftheelectrodeandslowlypeel
itaway.Avoidtouchingthegelasmuchas
possible.
DONOTpeeltheelectrodeoffbythewire.

9
RECOMMEND MASSAGE POINTS
4.Removetheelectrodesbacktothestorage
bagandresealtightlytopreventdry-out.Store
atroomorcooltemperatureandkeepoutof
directsunlight.
Autres manuels pour AS8012
2
Table des matières
Autres manuels Auvon masseur