Aura Systems AuraGen Manuel utilisateur

AURAGEN®INDUCTION POWER SOURCE
OWNER’S MANUAL
M1120221-3
Date: 090630


Typical Under-Hood Installation
Hydraulically Driven
Power Take Off (PTO) Driven

The AuraGen®Induction Power Source provides several distinct advantages over portable gen-
erator systems. These include:
Mobile Power:
With the AuraGen system you have electrical power with you wherever you go with your vehicle.
There is also no output power penalty for changes in altitude or ambient temperature.
Load-Following:
Unlike typical portable generator sets which run at a constant engine speed (usually 3,600 RPM),
the AuraGen systems produces clean, pure sine wave, 60 or 50 Hz electrical power at any en-
gine RPM. The output voltage and frequency will not fluctuate due to momentary or sustained
changes in engine speed.
Use of Automotive Engine:
Automobile engines are more efficient than small utility engines used in portable generators.
Modern electronic fuel injection systems continually optimize the engine performance and fuel
efficiency. The vehicle emission control system and muffler greatly reduce the amount of pollu-
tion and noise produced. The result is more automotive engine produced power, reduced noise,
and less pollution.
Maintenance Free:
“The AuraGen”
Once installed, the AuraGen system is virtually maintenance free. Forget about the daily small
engine maintenance of the carburetor, spark plugs, fuel system and other routine problems
associated with traditional generators. Just have the AuraGen serpentine drive belt inspected
periodically (refer to supplied Service Manual).

M1120221-3, 090630 Owner’s Manual - i
TABLE OF CONTENTS
THANK YOU FOR CHOOSING OUR PRODUCT ................................................... ............ 1
SAFETY ............................................................................................................................ 1
ABOUT THIS MANUAL ..................................................................................................... 1
CUSTOMER RECORD ....................................................................................................... 1
THE AURAGEN SYSTEMS ................................................................................................ 2
DIAGRAM OF TYPICAL AURAGEN VEHICLE INSTALLATION....................................... 4
DIAGRAMS OF SPECIFIC AURAGEN SYSTEMS.......................................................... 5
SAFETY PRECAUTIONS .................................................................................................. 7
GENERAL SAFETY PRECAUTIONS.............................................................................. 8
EXHAUST GASES......................................................................................................... 8
MOVING PARTS CAN CAUSE SEVERE PERSONAL INJURY OR DEATH..................... 8
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH............. 8
SPECIAL OPERATIONAL PRECAUTIONS ................................................................... 8
GENERAL OPERATING INSTRUCTIONS ......................................................................... 9
ALL-AC, AC/DC, ALL-DC SYSTEMS ............................................................................. 9
VEHICLES WITHOUT AUTO START......................................................................... 9
VEHICLES WITH AUTO START ............................................................................... 9
INVERTER/CHARGER SYSTEM................................................................................... 10
VEHICLE ENGINE RUNNING - CONTROL SWITCH OFF ........................................ 10
VEHICLE ENGINE RUNNING - CONTROL SWITCH ON........................................... 10
VEHICLE ENGINE OFF - CONTROL SWITCH OFF.................................................. 10
VEHICLE ENGINE OFF - CONTROL SWITCH ON.................................................... 10
TYPICAL ICS OPERATION....................................................................................... 10
OPERATION WHILE STATIONARY ................................................................................... 11
OPERATION WHILE DRIVING .......................................................................................... 11
HOW TO OBTAIN SERVICE ............................................................................................. 11
AURAGEN OPTIONAL EQUIPMENT ................................................................................ 11
REMOTE POWER STRIP.............................................................................................. 12
MANUAL TRANSFER SWITCH..................................................................................... 12
PUTTING YOUR AURAGEN SYSTEM TO USE ................................................................. 12
TYPICAL AURAGEN APPLICATIONS .............................................................................. 13
POWER CAPACITY .......................................................................................................... 13
WATTAGE REQUIREMENTS FOR TYPICAL APPLIANCES AND TOOLS ......................... 14
GENERAL INSPECTION ................................................................................................... 15
PROBLEM TROUBLESHOOTING ..................................................................................... 15
SYSTEM TROUBLESHOOTING GUIDE - ALL-AC, AC/DC AND ALL-DC ....................... 16
SYSTEM TROUBLESHOOTING GUIDE - INVERTER/CHARGER SYSTEM................... 18
AURAGEN SYSTEM SPECIFICATIONS ............................................................................ 20
ALL-AC ........................................................................................................................ 20
AC/DC ......................................................................................................................... 21
ALL-DC ........................................................................................................................ 22
6000X INVERTER/CHARGER ...................................................................................... 23
8500X INVERTER/CHARGER....................................................................................... 24
ALL-AC, ALL-DC, AC/DC/ENGINE-OFF INVERTER CHARGER SYSTEM...................... 25
ALL-AC, ALL-DC, AC/DC/ENGINE-OFF INVERTER CHARGER SYSTEM (Cont’d)........... 26
ALL-AC, ALL-DC, AC/DC/ENGINE-OFF INVERTER CHARGER SYSTEM (Cont’d)........... 27
AURAGEN/VIPER SINGLE & DUAL G8500YC INVERTER CHARGER SYSTEM........... 28
AURAGEN LIMITED WARRANTY ..................................................................................... 29
WARRANTY SERVICE OR REPAIR .................................................................................. 29
OWNER’S RESPONSIBILITY ....................................................................................... 29
NORMAL WEAR ........................................................................................................... 29
RETURN PROCEDURE ............................................................................................... 29
WARRANTY LIMITATIONS ........................................................................................... 30
DISCLAIMER OF IMPLIED WARRANTIES ................................................................... 30

M1120221-3, 090630
1 - Owner’s Manual
THANK YOU FOR CHOOSING OUR PRODUCT
Congratulations on the purchase of your new AuraGen®system. Whether you purchased the
AuraGen for work, recreation, or emergency power needs, we’re very confident you’ll be im-
pressed. The AuraGen family of products have been built for durability, with careful attention to
detail.
SAFETY
Do not attempt to operate or use your AuraGen system until after you have thoroughly
read and understand all safety precautions outlined in this manual.
ABOUT THIS MANUAL
This manual provides information about the AuraGen Induction Power Source models. Study it
carefully and comply with all warnings and cautions. Correct operation of this system and adher-
ence to a simple general inspection schedule will result in longer unit life, better performance and
safer usage.
CUSTOMER RECORD
On your AuraGen system components, you will find the model number and serial number on the
labels adhered to the AuraGen cover plate and side of the ECU. We recommend you record
these numbers in the space provided below. Refer to them should you need to contact your
authorized AuraGen Distributor/dealer regarding this product.
Part Number Serial Number
Induction Power Source
_______________ _______________
Electronic Control Unit (ECU)
_______________ _______________
Distributor/Dealer Name: _________________________________
Phone Number: _________________________________
Installation Date: _______________

M1120221-3, 090630 Owner’s Manual - 2
THE AURAGEN SYSTEMS
(U.S. Patents No. 5,734,217 and 6,157,175)
The AuraGen System includes:
(Also see diagrams on pages 3-5)
• Induction Power Source
• Electronic Control Unit (ECU)
• Control Panel
• Idle Control Unit (some vehicles)
• Mounting hardware and cables
(not shown)
Electronic Control Unit
Control Panel
Mechanical
Induction Power Source
Standard Inverter/Charger
Electronic
Idle Control
Induction Power Source
Dual-Tandem Generator
16000 Watts

M1120221-3, 090630
3 - Owner’s Manual
Optional Equipment Available:
• Remote Power Strip
• Manual Transfer Switch
Ask your authorized AuraGen Distributor/dealer about the optional equipment.
Manual Transfer SwitchRemote Power Strip

M1120221-3, 090630 Owner’s Manual - 4
Typical Engine Mounted AuraGen System
CONTROL AND POWER
CABLES ROUTED UNDER
VEHICLE TO REAR-MOUNTED
ELECTRONIC CONTROL UNIT
REMOTE POWER STRIP
(OPTIONAL)
RECEPTACLE
OUTLET BOX
AURAGEN MOBILE
GENERATOR
THROTTLE CONTROL
(LOCATION MAY VARY)
MOUNTING BRACKET
(ENGINE AND VEHICLE
SPECIFIC)
CONTROL UNIT
ON/OFF - STATUS LEDs
(USUALLY LOCATED UNDER DASH)
ELECTRONIC CONTROL UNIT
IDLE CONTROL
(LOCATION MAY VARY)
AURAGEN INDUCTION POWER SOURCE

M1120221-3, 090630
5 - Owner’s Manual
All-AC: Provides 120 VAC power to GFI outlets and/or 240 volt outlets. An optional remote
power strip with 120 VAC and/or 120/240 VAC service is also offered.
AC/DC: Provides 120 VAC power to GFI outlets and 14 or 28 VDC connected to the vehicle
batteries. An optional remote power strip with 120 VAC service is also offered.
Ce manuel convient aux modèles suivants
4
Table des matières