artisan cFP-2200 Manuel utilisateur

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

FIELDPOINT OPERATING INSTRUCTIONS AND SPECIFICATIONS
cFP-2200/2210/2220
Intelligent Real-Time Controllers for Compact FieldPoint
Contents
What You Need to Install the cFP-22xx.................................................. 2
Safety Guidelines .................................................................................... 3
Mounting the Compact FieldPoint Backplane ........................................ 4
Installing the cFP-22xx on the Backplane............................................... 15
Installing I/O Modules on the Backplane ............................................... 16
Installing Connector Blocks on the Backplane....................................... 17
Connecting the cFP-22xx to a Network .................................................. 18
Wiring Power to the cFP-22xx ................................................................ 19
Powering On the cFP-22xx ..................................................................... 22
Connecting Serial Devices to the cFP-22xx............................................ 22
External Digital Inputs and Outputs (cFP 2220 Only)............................ 25
Connecting USB Flash Drives to the cFP-2220...................................... 26
Using the Internal Real-Time Clock ....................................................... 26
Configuring DIP Switches ...................................................................... 27
Using the Reset Button ........................................................................... 29
Understanding LED Indications.............................................................. 29
Removable CompactFlash (cFP-2220 Only) .......................................... 30
File Transfer Capability .......................................................................... 30
Remote Front Panels ............................................................................... 31
Resetting the Network Configuration of the cFP-22xx ........................... 31
Troubleshooting ...................................................................................... 32
Specifications .......................................................................................... 33
Where to Go for Support......................................................................... 40
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

cFP-2200/2210/2220 2 ni.com
Figure 1. cFP-22xx, Front and Bottom Views
This document describes how to mount the cFP-2200/2210/2220
controllers, how to connect the controllers to networks, and how to use
the features of the controllers. This document also contains specifications
for the controllers. In this document, the cFP-2200/2210/2220 controllers
are referred to inclusively as the cFP-22xx.
What You Need to Install the cFP-22xx
❑cFP-22xx intelligent real-time controller
❑cFP-BP-4 or cFP-BP-8 Compact FieldPoint backplane
❑Compact FieldPoint I/O modules
1 RS-232 Serial Port
2 RJ-45 Ethernet Port 1
3 Removable Compact Flash (cFP-2220 Only)
4 Status LED
5 Power LED
6 User-Configurable LEDs
7 DIP Switches
8 USB Port (cFP-2220 Only)
9 RJ-45 Ethernet Port 2 (cFP-2220 Only)
10 Reset Button
11 Power Connector
12 Digital Input/Output Terminals (cFP-2220 Only)
13 RS-485 Serial Port (cFP-2220 Only)
14 RS-232 Serial Port (cFP-2220 Only)
15 RS-232 Serial Port (cFP-2210 and cFP-2220 Only)
3
4
6
7
8
9
10
12
13
14
15
11
5
2
1
Bottom
Front
CAUTION – SEE USER MANUAL
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

©National Instruments Corporation 3 cFP-2200/2210/2220
❑Compact FieldPoint connector blocks and/or cables
❑Ethernet cable
❑Mounting hardware (DIN rail, panel-mount, or rack-mount accessory)
❑Two M4 or number 10 panhead screws (for panel mounting only)
❑Number 2 Phillips screwdriver
❑14 AWG (1.6 mm) wire with ring lug to fit #8 screw
❑11–30 VDC Power supply
❑PC running Windows
❑FieldPoint software 6.0.1 or later
❑LabVIEW Real-Time Module 8.5.1 or later
Safety Guidelines
Operate the cFP-22xx only as described in these operating instructions.
Safety Guidelines for Hazardous Locations
The cFP-22xx is suitable for use in Class I, Division 2, Groups A, B, C, D,
T4 hazardous locations; Class 1, Zone 2, AEx nL IIC T4 and Ex nL IIC T4
hazardous locations; and nonhazardous locations only. Follow these
guidelines if you are installing the cFP-22xx in a potentially explosive
environment. Not following these guidelines may result in serious injury
or death.
Caution Do not disconnect the power supply wires and connectors from the controller
unless power has been switched off.
Caution You must connect the protective earth (PE) ground terminal on the cFP-BP-x
backplane to the system safety ground. The backplane PE ground terminal has the
following symbol stamped beside it: . Connect the backplane PE ground terminal to
safety ground using 14 AWG (1.6 mm) wire with a ring lug. Use the 5/16 in. panhead screw
shipped with the backplane to secure the ring lug to the backplane PE ground terminal.
Caution Substitution of components may impair suitability for Class I, Division 2.
Caution For Zone 2 applications, install the Compact FieldPoint system in an enclosure
rated to at least IP 54 as defined by IEC 60529 and EN 60529.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

cFP-2200/2210/2220 4 ni.com
Caution For Zone 2 applications, install a protection device across the external power
supply and the COM terminal. The device must prevent the external power supply voltage
from exceeding 42 V if there is a transient overvoltage condition.
Caution The USB port on the cFP-2220 has been tested with the following USB flash
drives: SanDisk™Cruzer®Micro, PNY™Optima Pro Attaché®, and Swissbit®
Swissmemory ™USB Minitwist. Use only these USB flash drives with the cFP-2220.
Special Conditions for Hazardous Locations Use
in Europe
The cFP-22xx has been evaluated as Ex nL IIC T4 equipment under
DEMKO Certificate No. 08 ATEX 0724339X. Each controller is marked
II 3G and is suitable for use in Zone 2 hazardous locations. If you are
using the cFP-22xx in Gas Group IIC hazardous locations, you must ensure
that the ambient temperature is within the range –40 ≤Ta ≤ 70 °C, and you
must use the controller in an NI backplane that has been evaluated as
EEx nC IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
Mounting the Compact FieldPoint Backplane
You can mount the cFP-BP-xbackplane on a 35 mm DIN rail, on a panel,
or in a standard 19 in. rack. NI recommends DIN rail mounting for the
cFP-BP-4 only. Use panel mounting or rack mounting for the cFP-BP-8.
Use the panel mounting method for high shock and vibration applications.
Before using any mounting method, record the serial number from the back
of the backplane. You will be unable to read the serial number after you
have mounted the backplane.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

©National Instruments Corporation 5 cFP-2200/2210/2220
To ensure maximum cooling efficiency, mount the Compact FieldPoint
system so that the I/O module vents are at the top and bottom, as shown in
the following figure:
Figure 2. cFP-22xx Installed on cFP-BP-4 Mounted Upright
Caution Your installation must meet the following requirements for space and cabling
clearance:
• Allow at least 51 mm (2 in.) all around the backplane for air circulation.
• Allow 38 mm (1.5 in.) below and 51 mm (2 in.) above the controller.
Compact FieldPoint
cFP-2220
cFP-DI-304 cFP-DI-304 cFP-DI-304 cFP-DI-304
2829 30 31 2829 30 31 2829 30 31 2829 30 31
POWER
STAT U S
POWER
READY
POWER
READY
POWER
READY
POWER
READY
IP RESET
SAFE MODE
NO APP
CONSOUT
USER2
USER1
LINK/
ACTIVITY
RESET
10/100 10/100
V1
V2
C
C
1/RS-232
INPUT
11-30 V
1.5 A MAX
1
2
ABCD
CAUTION – SEE USER MANUAL
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

cFP-2200/2210/2220 6 ni.com
Figure 3. cFP-22xx Installed on cFP-BP-x, Bottom View with Dimensions
Figure 4. cFP-22xx Installed on cFP-BP-4, Front View with Dimensions
Cabling
Clearance
4 slots= 246 mm (9.68in.)
8slots= 441 mm (17.4 in.)
Cooling Outline 51 mm (2 in.) Cooling Outline 51 mm (2 in.)
Min. 182 mm (7.18in.)
106 mm (4.18in.)
4 / RS-485
DI / DO
C
C
C
C
O2
O1
12
11
3/ RS-232
2 / RS-232
Cablin
g
Clearance Coolin
g
Outline 51 mm (2 in.) All Around
4 slots= 246 mm (9.68in.)
8slots= 441 mm (17.4 in.)
127 mm
(5.00 in.)
Min. 165 mm
(6.50 in.)
CAUTION – SEE USERMANUAL
Compact FieldPoint
cFP-2220
4567
0123
8 9 1011
12 13 14 15
16 17 18 19
20 21 22 23
24 25 26 27
28
cFP-DI-304
29 30 31
POWER
STATUS
POWER
READY
IP RESET
SAFE MODE
NO APP
CONS OUT
USER2
USER1
LINK/
ACTIVITY
RESET
10/100 10/100
V1
V2
C
C
INPUT
11-30 V
1.5 A MAX
ABCD
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

©National Instruments Corporation 7 cFP-2200/2210/2220
Figure 5. cFP-BP-8, Back View with Dimensions
Figure 6. cFP-BP-4, Back View with Dimensions
Caution Make sure that no I/O modules are in the backplane before mounting it.
104.78mm
(4.1 in.)
63.50 mm
(2.5 in.)
22.23mm
(0.9 in.)
33.15 mm
(1.3in.)
129.54 mm
(5.1 in.)
311.40 mm
(12.3in.)
387.60 mm
(15.3in.)
407.80 mm
(16.1 in.)
127.00 mm
(5.0 in.)
440.94 mm
(
17.4 in.
)
104.74 mm
(4.1 in.)
63.46 mm
(2.5 in.)
127.00 mm
(5.0 in.)
22.19 mm
(0.9 in.)
34.04 mm
(1.3in.)
84.84 mm
(3.3in.)
161.04 mm
(6.3in.)
211.84 mm
(8.3in.)
245.87 mm
(9.6 in.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

cFP-2200/2210/2220 8 ni.com
Mounting the Backplane on a DIN Rail
The DIN rail mounting kit is NI part number 778614-01. You need one kit
to mount the cFP-BP-4 on a standard 35 mm DIN rail. Complete the
following steps to mount the backplane on a DIN rail.
1. Fasten the DIN rail clip to the cFP-BP-4 using a number 2 Phillips
screwdriver and the 8-32 ×5/16 in. countersink screws shipped with
the mounting kit.
Figure 7. Installing the DIN Rail Clip on the cFP-BP-4
Caution Do not use screws longer than 5/16 in. to fasten the DIN rail clip to the backplane.
2. Insert one edge of the DIN rail into the deeper opening of the DIN rail
clip, as shown in Figure 8.
Figure 8. One Edge of DIN Rail Inserted in Clip
1 DIN Rail Clip 2 DIN Rail Spring 3 DIN Rail
NATIONAL
INSTRUMENTS
2
1
3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

©National Instruments Corporation 9 cFP-2200/2210/2220
3. Press down firmly on the backplane to compress the spring until the
clip locks in place on the DIN rail.
4. Connect the PE ground terminal on the backplane to safety ground.
Caution Disconnect power and make sure that no I/O modules are in the backplane before
removing it from the DIN rail.
Mounting the Backplane on a Panel
The horizontal panel-mount kit has mounting holes on the sides of the
backplane and is NI part number 778616-01. The vertical panel-mount kit
has mounting holes on the top and bottom of the backplane and is NI part
number 778688-01. Complete the following steps to mount the system on
a flat surface.
1. Fasten the panel-mount plates to the back of the cFP-BP-xusing a
number 2 Phillips screwdriver and the 8-32 ×5/16 in. countersink
screws shipped with the kit. You must use these screws because they
are the correct depth and thread for the plates and backplane.
Figure 9. Installing the Horizontal Panel-Mount Kit on the cFP-BP-4
NATIONAL
INSTRUMENTS
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels artisan Contrôleurs

artisan
artisan RS-617S Manuel utilisateur

artisan
artisan Altivar 16 Series Manuel utilisateur

artisan
artisan 5400 Manuel utilisateur

artisan
artisan Achronix Bitporter Manuel utilisateur

artisan
artisan 5400-E Manuel utilisateur

artisan
artisan PMAC2-Lite Guide rapide de l'utilisateur

artisan
artisan DMC-41-3 Series Manuel utilisateur

artisan
artisan 5400-ES Manuel utilisateur