User Manual User Manual 0908
EN Maintenance
EN Specications
Dimensions 132*103*146mm
Tank capacity 300ml
Mist amount About 40ml/hr
Power input DC24V 650mA
Rated power 15.6 W
In order to ensure product safety and the eciency of your diuser,
it is recommended to undertake a maintenance clean aer every 5-6
uses.
1. Unplug the power cord from the power socket and the base of
your diuser.
2. Remove the cover.
3. Carefully empty any remaining water from the diuser. To avoid
water entering the device, do not tilt to the side where the air
outlet is (where the mist comes out).
Note: Do not touch the ultrasonic board at the center of
the water tank. In case of maintenance where it needs to be
cleaned, please use cotton swabs.
4. Using a damp cloth previously soaked in water diluted with dish
detergent, wipe down the body.
5. Re-ll the diuser with plain water and let it mist for 30 minutes
to clean out any excess oils. Carefully drain aer use.
6. If any essential oils have dropped on the outside of the water
tank, wipe down with a damp cloth.
7. Place the cover back on the diuser.
Note: Do not use chemicals such as benzine thinner, alcohol
hydrochloric detergents, or enzyme detergents. May cause
damage to device and emit poisonous gases. Only use neutral
detergents.