Armstrong Rada Mode d'emploi

1
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
Rada Digital Faucet
App Programming Guide

2
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
Connecting your iPad to the Rada Digital Faucet................................... 5
Set the basic parameters .......................................................................... 8
Table of Contents
Set the date and time ...........................................................................8
Create a unique name........................................................................... 11
Set the region (language) and chose Farenheit/Celcius....................... 13
Change the default pin........................................................................... 14
Set operation mode On/O.................................................................16
Allow the use of full cold .......................................................................18
Select the temperature adjustment and default temperature................20
Select normal operating ow .................................................................22
Set operational timings ..........................................................................24
Set the outlet for your application........................................................... 16
Set automated duty ush and manual activation................................27
Set automated cold ush and manual activation .................................34
Set thermal disinfection and manual activation ...................................42
Set automated duty ush parameters and manual activation ................ 27
Save a preset .....................................................................................48
Applying a preset...................................................................................50
Saving and applying a preset ................................................................. 48
General................................................................................................... 4

3
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
View data logs .................................................................................... 51
Export data logs.....................................................................................54
Example of data logs.............................................................................55
Accessing and exporting data logs......................................................... 51
Run a temperature check ....................................................................... 56
Health check panels explained...........................................................57
Clear an error.........................................................................................61
Valve health checks................................................................................ 57

4
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
The Rada AP1 iPad App is available from the Apple App Store
free of charge and is required for programming the Rada
Digital Faucet. Search Rada AP1.
The App is only compatible with an Apple iPad. It is currently
not compatible with Apple iPhones or Android devices.
The IOM is available from Armstrong International.
The Rada Digital Faucet instruction videos are on
Armstrong International’s YouTube page.
More information is available from your local Armstrong Representative or from
Armstrong International www.armstronginternational.com
General

5
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
Connecting your iPad to the Rada Digital Faucet
Open the Rada AP1 App on your
iPad.
Ensure Bluetooth is enabled on
your iPad. Put the Faucet into
service mode by placing the Rada
Magnetic Key (included) near the
front of the tap. The Faucet is in
service mode when the spanner
wrench is red.
Click in the Valve Setup panel.
1
2
3

6
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
Click on Bluetooth.
The App will search for the
Faucet.
Ensure you are near the Faucet
you’re programming and the
spanner wrench is red.
You’ll see the Faucet appear in the
Valve Search box.
It will appear as a serial number.
Once it appears, click on it.
Enter the Pin. The default pin is
5945. Click Apply.
5945
4
6
5
7

7
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
The faucet is connected when the
indicator bars are lit.
Once connected click the back
button to return to the home screen
(you can do this at any point during
programming).
8
10
9
You’re now back on the Home
Screen.

8
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
Set the basic parameters
Here you can:
Click on Valve Setup.
Set the date and time
Create a unique Faucet name
Setting the Region (Language) and Chosing Fahrenheit / Celcius
Changing the Default Pin.
Note: To perform thermal disinfection and duty ush it is essential the date and
time are programmed accurately. Failure to do so will result will compromise the
datalogging function.
Set the date and time
Click Edit in Installation Setup
panel.
1
2

9
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
In the Valve and Date panel select
either the Time and / or Date eld.
Scroll to set current date and
time. When complete, click Done.
Click the forward arrow.
3
4
Click Apply to Valve.
5

10
Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093
USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com
The Faucet will let you know it is
making the changes.
Note: any other changes made in
other tiles will be applied when you
select Apply to Valve button.
Date and time have now been set.
6
7
Autres manuels pour Rada
1
Table des matières
Autres manuels Armstrong Équipements de cuisine et de salle de bain
Manuels Équipements de cuisine et de salle de bain populaires d'autres marques

Alpha Bidet
Alpha Bidet Alpha One Manuel utilisateur

InSinkErator
InSinkErator H/HC3300 Manuel d'installation

Clou
Clou Xo type 1 Manuel utilisateur

Kohler
Kohler Contra 26448T-4 Manuel utilisateur

Grohe
Grohe Bridgeford 20 158 Manuel utilisateur

Hans Grohe
Hans Grohe Croma Select S 180 Showerpipe EcoSmart... Manuel utilisateur