Areca ARC-1330 Series Manuel utilisateur

ARC-1330 Series
(PCIe 3.0 x8 Lanes 12Gb/s SAS Host Adapters )
SAS Host Adapters
USER’S Manual
Version: 1.2
Issue Date: September, 2021

Copyright and Trademarks
The information regarding products in this manual is subject to change
without prior notice and does not represent a commitment on the part
of the vendor, who assumes no liability or responsibility for any errors
that may appear in this manual. All brands and trademarks are the
properties of their respective owners. This manual contains materials
protected under International Copyright Conventions. All rights
reserved. No part of this manual may be reproduced in any form or by
any means, electronic or mechanical, including photocopying, without
the written permission of the manufacturer and the author.
FCC Statement
This equipment has been tested and found to comply with the lim-
its for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against in-
terference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation.
Manufacturer’s Declaration for CE Certication
We conrm ARC-1330 series SAS host adapters have been tested and
found compliant with the requirements in the council directive relating
to the EMC Directive 2004/108/EC. Regarding to the electromagnetic
compatibility, the following standards were applied:
EN 55022: 2006, Class B
EN 61000-3-2: 2006
EN 61000-3-3: 1995+A1: 2001+A2: 2005
EN 55024:1998+A1:2001=A2:2003
IEC61000-4-2: 2001
IEC61000-4-3: 2006
IEC61000-4-4: 2004
IEC61000-4-5: 2005
IEC61000-4-6: 2006
IEC61000-4-8: 2001
IEC61000-4-11: 2004

Contents
1. Introduction ................................................................ 6
1.1 Overview .........................................................................6
1.2 Features ..........................................................................7
2. Hardware Installation ................................................. 9
2.1 Before Your Begin Installation .............................................9
2.2 Board Layout.................................................................. 10
2.3 Installation..................................................................... 14
1: Internal Mini SAS HD SFF-8643 to 4x SATA Cable ............... 17
2: Internal Mini SAS HD SFF-8643 to 4xSFF-8482 Cable .......... 17
3: Internal Mini SAS HD SFF-8643 Cable................................ 18
4: External Mini SAS HD SFF-8644 Cable ............................... 19
3. Host_BIOS Setup Manager ........................................ 23
3.1 Starting the Host_BIOS Setup Manager.............................. 23
3.2 Main Menu .................................................................... 25
3.2.1 Physical Devices......................................................... 27
3.2.1.1 Display Device Information ..................................... 28
3.2.1.2 Verify Disk ............................................................ 29
3.2.1.3 Identify Disk ......................................................... 30
3.2.2 Miscellaneous Settings ................................................ 31
3.2.2.1 SATA NCQ Support................................................. 32
3.2.2.2 SMART Status Polling ............................................. 32
3.2.2.3 Disk Write Cache ................................................... 33
3.2.2.4 PCI Interrupt Type ................................................. 33
3.2.2.5 PCIE Read Request Size.......................................... 34
3.2.2.6 Max. Phy Link Rate ................................................ 34
3.2.2.7 Max. Command Xfer Length .................................... 35
3.2.2.8 Delay Before Driver Load ........................................ 36
3.2.2.9 INT 13 Service ...................................................... 36
3.2.2.10 Clear Persistent Mapping....................................... 37
3.2.2.11 Staggered Spin-up Cong ..................................... 38
3.2.2.12 Reset BIOS Parameters......................................... 40
3.2.3 System Information.................................................... 41
4. Driver Installation ..................................................... 42
4.1 Creating the Driver Disk................................................... 42
4.2 Driver Installation for Windows ......................................... 43
4.2.1 Installing Controller on an Existing Windows ................. 43
4.2.2 Uninstall controller from Windows ................................ 44

4.3 Driver Installation for Linux .............................................. 45
4.4 Driver Installation for FreeBSD.......................................... 45
4.5 Driver Installation for Mac OS X ........................................ 46
4.5.1 Installation Procedures................................................ 46
4.5.2 Making Volume Sets Available to Mac OS X .................... 47
Appendix A .................................................................... 49
Upgrading Adapter Flash ROM Process..................................... 49
Upgrading BIOS Through Oash.exe Flash DOS Utility ............... 49


INTRODUCTION
6
1. Introduction
This section presents brief overview of the SAS 12Gb/s host adapters:
ARC-1330-8i, ARC-1330-8x and ARC-1330-4i4x.
1.1 Overview
ARC-1330 series host adapters provide a blazing-fast storage con-
nectivity solution with enhanced reliability and performance and a
wide variety of internal and external connector congurations to
support any application and tiered storage solution. The SAS host
adapters enable large-scale direct attach storage (DAS) arrays
through external 12Gb/s ports, driving up to 128 end-point devices
for SFF-8644 connector. With connectivity options including 8-in-
ternal ports, 8-external, and 4-internal/4-external ports, ARC-1330
series 12Gb/s host adapters are ideal for large capacity external
server storage RAID and no-RAID enclosure.
Unparalleled Performance
Areca PCIe 3.0 x 8 lanes 12Gb/s SAS host adapters are able to
connect to 12Gb/s, 6Gb/s and 3Gb/s SATA SAS/SATA hard disk
drives, allowing for tiered storage that optimizes costs and perfor-
mance. This is because SAS adapters leverage a common electri-
cal and physical connection interface that is compatible with SATA
technology. SAS drives are optimal when speed and reliability are
of the utmost concern, while SATA drives are appropriate when
capacity and cost are more important. Areca offers a diverse selec-
tion of SAS host adapter including a wide variety of internal and
external connector congurations to support any application, from
high-performance workstations to large-scale DAS arrays at high
performance concerns. System integrators can use the ARC-1330
host adapters to build large-scale storage array infrastructures that
support both SAS and SATA devices. The mixing drivers into serv-
ers can be felt immediately when using the ARC-1330 to develop
a tiered storage solution with hard disk drives (HDDs), solid state
drives (SSDs) and removable media (DAS/JBOD).

INTRODUCTION
7
Easy Management
A set of 8 green LEDs and 8 red LEDs are provided on the front
side of the MD2 low prole board to transport activity/fault sta-
tus for each of up to 8 attached devices. The global state of these
activity/fault indicators is also presented on two sets of header. The
adapters contain a BIOS set up utility that can access via hot key
at system BIOS boot-up screen. This pre-boot setup utility provides
exibility for customer to optimize the host adapter parameter. API
library for customer combines the ARC-1330 series function code to
its monitor utility. CLI and API code have supported a system level
ATA-8 microcode download for upgrading SATA disk rmware and
SES microcode download for upgrading enclosure expander rm-
ware.
1.2 Features
Hardware Specication
• PCIe 3.0 x8 lanes (x8, x4, and x1 lane widths)
• Up to 12Gb/s transfer rates per SAS port
• Support 3Gb/s, 6Gb/s and 12Gb/s SAS and SATA link rates
• Connects to SAS/SATA HDDs, solid state driver (SSDs) and
removable media (DAS/JBOD)
• Support a maximum 128 SAS/SATA devices using SAS expander
• Available in a low-prole form factor
• Low-prole bracket
• RoHS compliant
Serial Attached SCSI (SAS) 12Gb/s
• Serial Attached SCSI (SAS-3.0) compliant
• Supports wide port (Any combination of x1, x2, and 4x)
• Supports Serial SCSI Protocol (SSP)
• Supports SAS Management Protocol (SMP)
• Supports Serial ATA Tunneling Protocol (STP)
• Hot-plug capability
• Staggered spin-up control
Serial ATA 6Gb/s
• 6Gb/s compliant with speed negotiation to 3Gb/s
• Support programmable SATA signal voltage levels

INTRODUCTION
8
12Gb/s SAS Host Adapter
Model Name ARC-1330-8i ARC-1330-4i4x ARC-1330-8x
Host Bus Type PCIe 3.0 x8 Lanes
RAID Level Non-RAID
Form Factor MD2 Low Prole
Drives Support 128 X 3Gb/s 6Gb/s and 12Gb/s SAS/SATA
Connector 2 x SFF-8643 1 x SFF-8643
1 x SFF-8644 2 x SFF-8644
Direct Attach Yes
Dimension(LxH) 167 X 64 mm
• Support staggered spin-up, hot-plug and Native Command Queu-
ing (NCQ)
• Support port multiplier
Easy Management
• Legacy BIOS setup utility
• Supports Command Line Interface (CLI)
• API library for customer to write monitor utility
• Enclosure management for internal port via LED and SES3/SGPIO
• Enclosure management for external port via SAS expander
• Support ATA-8 microcode download for upgrading SATA disk drive
rmware
• Support SES microcode download for upgrading enclosure
expander rmware
• ArcSAP quick manager for conguring and maintaining SAS host
adapter
Operating System
• Windows
• Linux (Red Hat and SuSE, ...)
• XenServer
• FreeBSD
• Mac OS X 10.5/macOS 10.12 or higher

HARDWARE INSTALLATION
9
2. Hardware Installation
This section describes the procedures for installing the ARC-1330 series
SAS host adapters.
2.1 Before Your Begin Installation
Thanks for purchasing the ARC-1330 series host adapters as your
data storage subsystem. This user manual gives simple step-by-
step instructions for installing and conguring the host adapters.
To ensure personal safety and to protect your equipment and data,
reading the following information package list carefully before you
begin installing.
Package Contents
If your package is missing any of the items listed below, contact
your local dealers before you install.
• 1 x PCIe 3.0 x 8 lanes host adapter in an ESD-protective bag
• 1 x Installation CD – containing driver, relative software, an
electronic version of this manual and other related manual
• 1 x ARC-1330 series quick installation guide
• 1 x Low-prole bracket

HARDWARE INSTALLATION
10
Figure 2-1, ARC-1330-8i Host Adapter
Table 2-1, ARC-1330-8i Connectors
Connector Type Description
1. (J1) Manufacture Purpose Port 10-pin header
2. (J2) Global Fault/Activity LED 4-pin header
3. (SCN1) SAS 1-8 Ports (Internal) SFF-8643
4. (D1,D5,D9,D13,
D2,D6,D10,D14) Fault LED for SAS Port 1-8 (SCN1) SMT LED
5. (D17,D21,D25,D30,
D20,D24,D28,D33) Activity LED for SAS Port 1-8 (SCN1) SMT LED
2.2 Board Layout
This section provides the board layout and connector/jumper for
the SAS host adapters.
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Areca Adaptateur