APsystems ECU-B Mode d’emploi

© All Rights Reserved
APsystems Energy Communication Unit ECU-B
Installation / User Manual
Please scan this QR code
to download our APPs
or click the link below:
http://q-r.to/1OrC

APsystems ECU-B Installation/User Manual
2
Table of Contents
1. Introduction........................................................................................................................................ 3
2. Interface Explanation..................................................................................................................... 4
2.1 Interface Layout................................................................................................... 4
2.2 Reset....................................................................................................................... 5
2.3 Power Connection Port.................................................................................... 5
2.4 Antenna................................................................................................................. 5
2.5 USB port................................................................................................................ 5
2.6 AP............................................................................................................................ 5
2.7 LED1.........................................................................................................................6
2.8 LED2........................................................................................................................6
3. Hardware Installation..................................................................................................................... 7
3.1 Preparation.............................................................................................................7
3.2 Selecting an Installation Location for the ECU-B....................................7
3.3 Installation.............................................................................................................7
3.4 Cable Connection............................................................................................... 8
3.5 Internet Connection...........................................................................................9
4. ECU-B User Interface....................................................................................................................10
4.1 Connecting to the ECU-B via the Local Wireless...................................10
4.2 Enter microinverters UID (serial numbers) into the ECU-B............... 11
4.3 Historical ID........................................................................................................ 12
4.4 Delete UID...........................................................................................................12
4.5 Grid Profile..........................................................................................................13
4.6 Time management........................................................................................... 14
4.7 ECU Network Settings....................................................................................14
4.8 Checking the commissioning of the ECU-B............................................16
4.9 Module................................................................................................................. 17
4.10 Data..................................................................................................................... 18
4.11 Inverter Connection Progress...................................................................... 18
4.12 Automatic System Check............................................................................. 19
4.13 ECU AP Settings..............................................................................................19
4.14 Do-It-Yourself Registration.......................................................................... 20
4.15 Settings...............................................................................................................20
5. Technical Data.................................................................................................................................21
6. Contact Information..................................................................................................................... 23

APsystems ECU-B Installation/User Manual
3
1. Introduction
The APsystems Energy Communication Unit (ECU-B) is the information
gateway for our inverters.ECU-B has been specially developed to monitor
small PV systems up to 4 PV modules.The unit collects module performance
data from each individual inverter and transfers this information to an
Internet database in real time, requiring only a single data and power cable.
Through the APsystems Energy Monitoring and Analysis software, the
ECU-B gives you precise analysis of each inverter and module in your solar
installation from APP. The user-friendly interface lets you access your solar
array in seconds.
Features
Collects individual PV module and microinverter statistics
Communicates in real time
Requires no additional wiring
The APsystems ECU-B is used in utility-interactive grid-tied applications,
typically consisting of five key elements:
APsystems microinverter(s)
APsystems Energy Communication Unit (ECU-B)
EMA Manager APP: for installer to set-up the ECU-B
EMA APP: to enable end-users to have access to the data and
performance of their system anytime, anywhere
APsystems Energy Monitoring and Analysis (EMA): web-based
monitoring and analysis system, for both end-users and installers
Figure 1
ECU APP
PV
Module
Ground
Neutral
Meter
Junction Box
Inverter
Internet EMA
Aps ystems Communicator
(EC U-R)
Apsystems Communicator
(ECU-B)
ECU APP
PV
Module
Ground
Neutral
Meter
Junction Box
Inverter
Internet EMA
Aps ystems Communicator
(EC U-R)

APsystems ECU-B Installation/User Manual
4
2. Interface Explanation
2.1 Interface Layout
The ECU-B interface includes, (figure 2) from left to right
Reset button
Wifi antenna connector (WLAN communication between ECU and
router)
power connection port
Zigbee antenna connector (communication between ECU and
microinverters)
Reset Antenna(WIFI) Antenna(ZIGBEE)
On the side ECU: from top to bottom are:
USB port : the USB interface is reserved.
AP button: in case there is need to activate the ECU-B hotspot (see
later in the document)
Figure 2
Power Connection Port
Invalid Ports
USB
AP

APsystems ECU-B Installation/User Manual
5
2. Interface Explanation
2.2 Reset
Press the Reset button for three seconds or longer, and the ECU-B will
automatically return to the default settings.
The wireless password will be changed to “88888888”.
Interface Explanat
2.3 Power Connection Port
The power connection port connects power through the power adapter.
2.4 Antenna
The antennas in the package should be connected to ECU-B. One antenna is
used for the communication between ECU-B and inverters, the other
antenna is used for the Wi-Fi connection between ECU-B and router.
2.5 USB port
The USB interface is reserved.
2.6 AP
The AP button enables to turn on the ECU wifi hotspot. When setting up the
ECU, installer needs to first connect to the ECU hotspot via his smart phone
or tablet.
Press the AP button for a few seconds: the ECU hotspot will be live for one
hour. If more time is needed to set-up the ECU, press the AP button to
reactivate the hotspot.

APsystems ECU-B Installation/User Manual
6
2. Interface Explanation
Figure 3
2.7 LED1
LED1 will be ON (green light) when the ECU is powered ON.
2.8 LED2
LED2 will be ON (green light) when the ECU is exchanging data with the
EMA server.
When you haven’t entered microinverters UID into the ECU-B, or The ECU
cannot connect to the EMA server, LED2 is OFF.
LED1
LED2

APsystems ECU-B Installation/User Manual
7
3. Hardware Installation
3.1 Preparation
Make sure you have the following components ready before
beginning to install the ECU-B:
A dedicated standard AC electrical outlet (located as close as
possible of the PV array to ensure good communication between
ECU and microinverters).
A wireless router.
A smartphone or tablet with EMA Manager APP ready to use (see
page 10).
3.2 Selecting an Installation Location for the ECU-B
Choose a location that is as close as possible of the PV array.
The ECU-B is NOT rated for outdoor use. If installing outdoor,
ensure that the ECU-B is put in a waterproof box, and that the
antenna (wifi and Zigee) are placed outside of the box to ensure
optimum communication. In case you need to use extension
antennas to be closer to the PV array, please make sure the
extension antennas are Wifi 2.4GHz with SMA connectors
male/female. These extension antennas are not supplied by
APsystems, but can be purchased at any electrical/PV shop.
3.3 Installation
1) Using a Wall Mount
When mounting the ECU-B to a wall, make sure to select a cool, dry
indoor location.
Depending on the wall surface you are mounting the ECU-B to, use
either two drywall screws or wall anchors, installed 100 mm apart
(The drywall screws and wall anchors are not included in the ECU-B
kit).
Align and slide the ECU-B onto the mounting screws.
Figure 4

APsystems ECU-B Installation/User Manual
8
3. Hardware Installation
2) if the ECU-B is not mounted on a wall mont, you can put it anywhere on
a flat surface or furniture, close to a power outlet.
3.4 Cable Connection
1) Using a Wall Mount
Connect the adapter to the power connection port on the top of the
ECU-B.
The antennas used for Zigbee port and WI-FI port are exactly the same
type, no need to distinguish.
Figure 5

APsystems ECU-B Installation/User Manual
9
3. Hardware Instrallation
2)Power Distribution Cabinet Installation
Install the socket on the guide rail (The socket will not be supplied
by APsystems Please prepare it yourself).
Connect the adapter to the power connection port on the top of the
ECU-B.
ECU antennas must be left outside of the cabinet, even if the cabinet is
made of plastic. Please make sure the extension antennas are Wifi
2.4GHz with SMA connectors male/female. These extension antennas
are not supplied by APsystems, but can be purchased at any
electrical/PV shop.
3.5 Internet Connection
Use ECU-B internal WLAN (see Manage the WLAN connection ).
Figure 6
Figure 7

APsystems ECU-B Installation/User Manual
10
4. ECU-B User Interface
Please scan QR code below to have access to our products and APP
catalogue, or click this link to download our APPs: http://q-r.to/1OrC.
EMA Manager APP: for installers
Professional installers: all features available
DIY (Do It Yourself) installers: only ECU_APP features available
EMA APP: for end-users only
4.1 Connecting to the ECU-B via the Local Wireless
Make sure you have downloaded the EMA Manager APP on your
smartphone or tablet
Make sure the ECU-B hotspot is activated (if not, press the AP
button for a few second)
Open Settings > Wi-Fi in your smartphone or tablet
Select ECU-B hotspot: name is ECU_B_2163XXXX (mimicking
ECU-B serial number)
Connect your smartphone or tablet to the ECU-B hotspot. Default
password is “88888888” (8 times 8)
Once the connection is established with the ECU-B hotspot, open
the EMA Manager APP.
Select “ECU APP” to enter into the commissioning tool (you can
access to ECU APP without any login or password).
Autres manuels pour ECU-B
2
Table des matières
Autres manuels APsystems Système de conférence
Manuels Système de conférence populaires d'autres marques

Kramer
Kramer VIA GO Manuel utilisateur

AVT
AVT MAGIC AC1 Go Manuel utilisateur

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Manuel utilisateur

Sony
Sony PCS-I150 Manuel utilisateur

Middle Atlantic Products
Middle Atlantic Products VTC Series Manuel utilisateur

Prentke Romich Company
Prentke Romich Company Vanguard Plus Mode d’emploi