Applied Comfort COOLFLOW32 Manuel utilisateur

COOLFLOW32
USER MANUAL
TPHE10G10EG
230V,60HZ WITH ELECTRIC HEAT
WALL MOUNTED TWIN PIPE AIR CONDITIONER
WITH HEAT PUMP AND WIFI SMART APP

1
CONTENTS
SAFETY AND INSTRUCTIONS 2
PRODUCT OVERVIEW 7
PRODUCT DIAGRAM 7
F
EATURES 8
WHAT’S INCLUDED 8
INSTALLATION 9
TOOLS REQUIRED 10
I
NSTALLATION 13
O
PERATION 14
C
ONTROL PANEL 14
R
EMOTE CONTROL 14
FUNCTIONS 16
W
IFI SETUP AND SMART FEATURES 18
S
ETUP
REGISTER THE APP
C
ONNECTING USING BLUETOOTH & WIFI 20
23
TROUBLESHOOTING
24
ERROR CODES
19

2
Safety and Instructions
READ ALL INSTRUCTIONS BEFORE USE.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance.
Always read and follow all safety messages.
You may be killed or seriously injured if you do not follow instructions.
You may be injured or cause damage to the product if you do not follow instructions.
Fuse Parameter for the main control board
Voltage:AC 250V
Current:15 A
Thissymbolshowsthatthisapplianceusesaflammablerefrigerant.
Iftherefrigerantisleakedandexposedtoanexternalignitionsource,there
isariskoffire.
WARNING
CAUTION
Thissymbolshowsthattheoperationmanualshouldbereadcarefully.
This symbol shows that a service personnel should be handling this
equipmentwithreferencetotheinstallationmanual.
Thissymbolshowsthatinformationisavailablesuchastheoperating
manualorinstallationmanual.

3
WARNING
To reduce the risk of explosion, fire, death, electric shock, scalding or injury to
persons when using this product, follow basic precautions, including the following:
INSTALLATION
●Before use, the appliance must be properly installed as described in this manual.
●Contact the authorized service technician for repair or maintenance of this unit.
●Contact the installer for installation of this unit.
●When the power cord is to be replaced, replacement work shall be performed by authorized
personnel only using only genuine replacement parts.
●Installation work must be performed in accordance with the National Electric Code by
qualified and authorized personnel only.
●Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.
Always plug into a grounded outlet.
●Do not under any circumstances, cut or remove the third (ground) prong from the power
cord.
●When installing or moving the appliance, be careful not to pinch, crush, or damage the
power cord.
●Plug in the power plug properly.
●Do not modify or extend the power cord.
●Do not start/stop operation by plugging/unplugging the power cord.
●If the cord/plug is damaged, have it replaced by an authorized service person using
authorized replacement parts.
●Use a dedicated circuit.
●Do not disassemble or modify the product.
●Adhere to all industry recommended safety procedures including the use of long-sleeved
gloves and safety glasses.
●Use care when unpacking and installing. The edges of the product may be sharp.
●Disconnect the power cord or circuit breaker before installing or servicing the appliance.
●Keep packaging materials out of the reach of children. These materials can pose a
suffocation risk to children.
●Store and install the product where the unit’s casing will not be exposed to temperatures
below freezing or exposed to outdoor weather conditions.
In other words, do not allow
the whole unit to be exposed to outdoor conditions
●Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
OPERATION
●Use this appliance only for its intended purpose.
●Never attempt to operate this appliance if it is damaged, malfunctioning, partially
disassembled, or has missing or broken parts, including a damaged cord or plug.
●Repair or immediately replace all power cords that have become frayed or otherwise
damaged
●Do not use a cord that shows cracks or abrasion damage along its length or at either end.
●Do not run cord under carpets or mats where it could be stepped on and damaged.
●Keep the cord out from under heavy objects like tables or chairs.

4
●Do not place the power cord near a heat source.
●Do not use an adaptor or plug the product into a shared outlet.
●Do not tamper with controls.
●If you detect a strange sound, a chemical or burning smell, or smoke coming from the
appliance, unplug it immediately, and contact dealer.
●Never unplug the appliance by pulling on the power cord. Always grip the plug firmly and
pull straight out from the outlet.
●Do not grasp the power cord or touch the appliance controls with wet hands.
●The air conditioner is not intended for use by young children or invalids without supervision.
●Young children should be supervised to ensure that they do not play with the air conditioner.
If water enters the product, turn off the power at the main circuit, then unplug the product
and call for service.
●If the product has been submerged, contact the dealer for instructions before resuming use.
●Unplug the product when unused for long periods.
●Unplug the product before cleaning. In the event of a gas leak (propane gas, etc.) do not
operate this or any other appliance. Open a window or door to ventilate the area immediately.
●This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by a person responsible
for their safety.
●To clean the interior, contact the dealer. Using harsh detergents may cause corrosion or
damage to the unit.
●Do not use solvent-based detergent on the product. Doing so can cause corrosion or
damage, product failure, electrical shock, or fire.
● Keep outdoor louvers unblocked and unobstructed by any obstacle closer than 36〫to the
wall face.
GROUNDING INSTRUCTIONS
●The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this
with a standard three-slot (grounding) wall power outlet to minimize the hazard of electric
shock. The customer should have the receptacle and circuit checked by a qualified electrician
to make sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD
(GROUND) PRONG FROM THE POWER PLUG.
Situations when the appliance will be disconnected occasionally; Because of potential
safety hazards, we strongly discourage the use of an adapter plug. However, if you wish
to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter,
available from most local hardware stores.
The large slot in the adapter must be aligned with the large slot in the receptacle to
assure a proper polarity connection.
●Attaching the adapter ground terminal to the wall receptacle cover screw does not ground
the appliance unless the cover screw is metal, and not insulated, and the wall receptacle is
grounded to make sure the receptacle is properly grounded.
●Disconnect the power cord from the adapter, using one hand on each. Otherwise, the
adapter ground terminal might break. Do not use the appliance with a broken adapter plug.
Situations when the appliance will be disconnected often; Do not use an adapter plug in these
situations. Unplugging the power cord frequently can lead to an eventual breakage of the
ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet
instead.

5
REFRIGERANT (FOR R32 ONLY)
CAUTION: FIRE
READING THE MAUAL CAREFULLY BEFORE USING THE APPLIANCE R32
refrigerant gas complies with international environmental directives. This
appliance contains approximately 19.40 Oz refrigerant gas.
Warnings
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources
(for example: open flames, an operating gas appliance or an operating electric heater)
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
The instructions should contain the following information:
That piping material, pipe routing, and installation shall include protection from physical
damage in operation and service, and be in compliance with Federal and Local
Regulations.
All field joints shall be accessible for inspection prior to being covered or enclosed.
-The installation of pipe-work shall be kept to a minimum.
-The provision shall be made for expansion and contraction of long runs of piping;
-The protection devices, piping, and fittings shall be protected as far as possible against
adverse environmental effects, for example, the danger of water collecting and freezing
in relief pipes or the accumulation of dirt and debris;
-The piping in refrigeration systems shall be so designed and installed to minimize the
likelihood of hydraulic shock damaging the system;
-The steel pipes and components shall be protected against corrosion with a rustproof
coating before applying any insulation;
-The flexible pipe elements shall be protected against mechanical damage,
excessive stress by torsion, or other forces, and that they should be checked for
mechanical damage annually;
-The precautions shall be taken to avoid excessive vibration or pulsation.

6
When using the product, the room should keep any required ventilation
openings clear of obstruction. Notice that servicing shall be performed only as
recommended by the manufacturer.
Unventilated area
●That an unventilated area where the appliance using flammable refrigerants is
installed shall be so constructed that should any refrigerant leak, it will not stagnate so
as to create a fire or explosion hazard.
●The non-fixed appliance shall be stored in an area where the size corresponds to the
room area as specified for operation.
●The non-fixed appliance shall be stored in a room without continuously operating open
flames or other potential ignition sources.
●The manufacturer should specify other potential continuously operating sources known
to cause ignition of the refrigerant used.
●The appliance shall be stored so as to prevent mechanical damage from occurring.
●Non-duct connected appliances containing A2L refrigerants with the supply and return
air openings in the conditioned space may have the body of the appliance may be
installed in open areas such as false ceilings not being used as return air plenums, as
long as the conditioned air does not directly communicate with the air of the false
ceiling.
Qualification of workers
●All operators or refrigeration circuit maintenance personnel should obtain a valid
certificate issued by an industry-recognized evaluation agency to determine that they
have the qualifications to safely handle refrigerants as required by the industry-
recognized evaluation scope.
●Only perform equipment maintenance and repairs in accordance with the methods
recommended by the appliance manufacturer. If other professional is required to
assist in maintenance and repairs, they should be carried out under the supervision
of personnel qualified to use flammable refrigerants.

7
PRODUCT OVERVIEW
PRODUCT DIAGRAM
FRONT
BACK
WALLHANGINGMOUNTS
BACKPANEL
AIRINLET
DRAINAGEPIPE AIROUTLET
FRONTPANEL
AIRINLET
CONTROLPANEL
LOUVER

8
FEATURES
Simple operation.
Self-evaporative function with energy saving technology.
Sleek design that seamlessly fits into any style home.
Bright LED screen-indicates temperature and current mode.
On / off timer function-allows you to choose when the unit operates.
WIFI App control providing additional functionality.
Three fan speeds.
Four modes to suit your every need including : Cooling / Heating / Fan / Dry
Silent running option , perfect for a restful night sleep.
WHATS INCLUDED
Sealing strip
*
DIAGRAMS FOR ILLUSTRATIVE PURPOSES ONLY
REMOTECONTROL
VENTCOVERASSEMBLY(X2)
(CHAIN,INDOORRINGAND
OUTDOORCOVER)
WALLBRACKET
PLASTICDUCTING
SHEET(X2)
FIXEDPLATE2PCSTAPPINGSCRE
(4x10mm)
WALLTEMPLATE
7PCSSCREWS(5×60mm)
7PCSWALLPLUGS
(8×40mm)
AIRCONDITIONER

9
INSTALLATION
Apply the sealing strip in the accessories along the edge of the back for the whole
perimeter of the machine, cut off the excessive length if needed.
Note:1.Thesealingstripshouldbeappliedalongtheedgeofthemachine,asshowninFigure1.
2. Pleasepeelthestripinglayeronthesealingstripgraduallywhileapplying.
3. Applyfromthebottomofthemachinefirst.
4. ThepositionofthecornershouldbeappliedasshowninFigure2.
5. Improperapplicationmaycauseextranoise.
Table des matières
Autres manuels Applied Comfort Climatiseur

Applied Comfort
Applied Comfort SCA Manuel du propriétaire

Applied Comfort
Applied Comfort VF20HA09K36E7MA90 Manuel utilisateur

Applied Comfort
Applied Comfort NYWC Series Manuel utilisateur

Applied Comfort
Applied Comfort SD Manuel utilisateur

Applied Comfort
Applied Comfort CALM U42 Series Guide de démarrage rapide

Applied Comfort
Applied Comfort VF20HA09K36E7M90 Manuel de service

Applied Comfort
Applied Comfort RSHPC Series Manuel utilisateur

Applied Comfort
Applied Comfort A26EC09L00EZA30 Guide de démarrage rapide

Applied Comfort
Applied Comfort SC Mode d’emploi

Applied Comfort
Applied Comfort NAEC SERIES Manuel utilisateur