American Range ARSCT-304 Manuel utilisateur

INSTALLATION MANUAL FOR
LEGEND RANGETOPS
MODEL NUMBERS:
ARSCT-244, ARSCT-304, ARSCT-366, ARSCT-364GD, ARSCT-364GR, ARSCT-486GD,
ARSCT-486GR, ARSCT-4842GD, ARSCT-484X2GR, ARSCT-6062GD,
ARSCT-6062GR, ARSCT-606GDGR
PROFESSIONAL QUALITY COOKING EQUIPMENT
13592 Desmond St., Pacoima, CA 91331 818.897.0808 888.753.9898 tel www.americanrange.com
DESIGN CLASS FUNCTION
© 2016 American Range
All Rights Reserved

Table of Contents
Warnings & Important Safety Instructions.......................................................................................1-4
Dimensions.............................................................................................................................................................5
Specications & Requirements ...............................................................................................................6-7
Clearance Dimensions...............................................................................................................................8-11
Electrical & Gas Locations ...........................................................................................................................12
Electrical & Gas Requirements..................................................................................................................13
Gas Requirements............................................................................................................................................14
General Instructions........................................................................................................................................15
Installation Instructions ..................................................................................................................................15
Installation Steps........................................................................................................................................16-19
Performance Check List................................................................................................................................20
Final Preparation ...............................................................................................................................................20
RANGETOPInstallation Manual
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com

Installation, Operation and
Maintenance Instructions
RANGETOP
Installation Manual
FOR YOUR SAFETY!
Do not store or use gasoline or
other ammable vapors or liquids
in the vicinity of this or any other appliance.
Model Number: __________________________________________
Serial Number: ___________________________________________
Purchase Date: ___________________________________________
Installed By: __________________________ Install Date:__________
Gas Type: _______________________________________________
Electrical Information: ______________________________________
FOR
YOUR
SAFETY
FOR
YOUR
SAFETY
Instruction to be followed in the event the user smells gas should be posted
in a prominent location. This information should be obtained by
consulting the local gas supplier.
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
WARNING!
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury
or death. Read the installation, operating and
maintenance instructions thoroughly before
installing or servicing this equipment.
WARNING
IMPROPER
INSTALLATION
WARNING
IMPROPER
INSTALLATION
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
1

• Before beginning, please read all the instructions carefully.
• DO NOT remove permanently afxed labels, warnings, or plates from product. This may void the warranty.
• All local and national codes and ordinances must be observed, installation must conform with local codes.
• The Installer must leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
• Installation and service must be performed by a qualied installer, service agency or gas supplier.
• Please ensure that the product is properly grounded.
Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your
appliance. Always read and obey all safety messages.
Installation Manual RANGETOP
IMPORTANT - PLEASE READ AND FOLLOW!
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
2
!
DANGER
!
WARNING
!
CAUTION
!
This is the SAFETY ALERT SYMBOL. This symbol alerts
you to hazards which will result in severe injury of death.
Hazards or unsafe practices which will result in severe
personal injury or death.
Hazards or unsafe practices which may result in severe
personal injury or death.
Hazards or unsafe practices which may result in minor
personal injury or property damage.

A Ground Fault Interrupter (GFI) shall be used as required by NFPA-70 (National Electric Code), Federal / State / Local laws or
local ordinances.
• The required use of a GFI is normally related to the location of a receptacle to any signicant sources of water or moisture.
• American Range will not warranty any problems resulting from GFI outlets which are not installed properly or do not meet
the requirements below.
IF THE USE OF A GFI IS REQUIRED, it should be:
• The receptacle type (breaker type or portable type not recommended).
• Used with permanent wiring only (temporary or portable wiring not recommended).
• On a dedicated circuit (no other receptacles, switches or loads in the circuit).
• Connected to a standard breaker or appropriate size (GFI breaker of the same size not recommended).
• Rated for class (5mA + 1mA trip current) as per UL 943 standard.
• In good condition and free from any loose-tting gaskets (if applicable in outdoor situations).
• Protected from moisture (water, steam, high humidity) as much as reasonably possible.
RANGETOPInstallation Manual
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
3
IMPORTANT - PLEASE READ AND FOLLOW!
To prevent possible damage to cabinets and cabinet nishes, use only materials
that will not discolor or delaminate and will withstand temperatures up to 194ºF
(90ºC). Heat resistant adhesive must be used if the product is to be installed in
laminated cabinetry, check with your builder or cabinet supplier to make sure
that the materials meet these requirements.
WARNING
!
The use of cabinets for storage above the oven may result in potential re
or burn hazard.
WARNING
!
To avoid risk of electrical shock, personal injury or death; verify your appliance
has been properly grounded in accordance with local codes or in absence of
codes, with the National Electrical Code (NEC).ANSI/NFPA 70 latest edition.
DANGER
!

RANGETOPInstallation Manual
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
4
This appliance should not be used for space heating. This information is based
on safety considerations.
WARNING
!
IMPORTANT - PLEASE READ AND FOLLOW!
Moving Hazard
To avoid risk of severe personal injury, this appliance requires two or more
personnel while handling or moving. Possible use of appliance moving devices
is recommended.
WARNING
!
Gas Leak Hazard
To avoid risk of personal injury or death, leak test of the appliance must be
conducted according to the manufacturer’s instructions, before placing appliance
in operation. Always check for gas leaks with soapy water solution.
DANGER
!
Do not use an open ame to check for gas leaks.

A
A
29"
29"
8"
13
"
TO THE KNOB
9"
TO THE KNOB
RANGETOPInstallation Manual
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
5
DIMENSIONS - RANGETOP
Step up version of Rangetop.
Model “A” In.
24 Stand & 24 SU 23.875
30 Stand & 24 SU 29.875
30 Stand & 24 SU 35.875
48 Stand & 24 SU 47.875
60 Stand & 24 SU 59.875

RANGETOPInstallation Manual
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
6
SPECIFICATIONS & ELECTRICAL REQUIREMENTS
RANGETOPS 24”, 30” & 36”
Description 24”Wide Models 30”Wide Models 36”Wide Models
Overall Width 24” 30” 36”
Overall Height To top of grate 9-5/16”
Step up models to the top of back island 13-1/8”
Overall Depth 29-3/4”
Gas Requirements 7”W.C. Natural & 11” LP
Gas Manifold Pressure 5”W.C. Natural & 10” LP
Electrical Requirements 120VAC, 60Hz Single Phase
Max Amp Usage 10 Amp
Surface Burner Rating Natural/LP
17,000 BTU
13,000 BTU
9,000 BTU
Griddle Burner rating N/A 20,000 BTU
Grill Burner rating N/A 30,000 BTU
Approximate Shipping Weight 90 lb. 110 lb. 150 lb.

RANGETOPInstallation Manual
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
7
SPECIFICATIONS & ELECTRICAL REQUIREMENTS
RANGETOPS 48” & 60”
Description 48”Wide Models 60”Wide Models
Overall Width 48” 60”
Overall Height To top of grate 9-5/16”
Step up models to the top of back island 13-1/8”
Overall Depth 29-3/4”
Gas Requirements 7”W.C. Natural & 11” LP
Gas Manifold Pressure 5”W.C. Natural & 10” LP
Electrical Requirements 120VAC, 60Hz Single Phase
Max Amp Usage 10 Amp
Surface Burner Rating Natural/LP
17,000 BTU
13,000 BTU
9,000 BTU
Griddle Burner rating 20,000 BTU
Grill Burner rating 30,000 BTU
Approximate Shipping Weight 190 lb. 230 lb.

RANGETOPInstallation Manual
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
8
CLEARANCE DIMENSIONS
• This cook top may be installed directly adjacent to existing 36” high base cabinets.
• Important: The top of the side trim must be 3/8” above the adjacent base cabinet countertop.
• The cook top cannot be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other vertical surfaces above 36”
high.
• There must be a minimum of 6” side clearance from the cook top to such combustible surfaces above the 36" counter height.
• Within 6" side clearance to combustible vertical surfaces above 36", the maximum wall cabinet depth must be 13" and wall
cabinets within this 6" side clearance must be 18" above the 36" high countertop.
• Wall cabinets above the cook top must be a minimum of 42" above the cook top cooking surface for the full width of the cook
top. This minimum height requirement does not apply if a cook top hood is installed over the cooking surface.
Note: Based on 24" deep cabinet.
Note: The minimum clearance for back wall is 0" with backguard or high shelf.
Note: If a cook top hood is installed, wall cabinets above the cook top have a different minimum clearance height.
Cook Top Width "A" Dimension
24" 30"
30" 36"
36" 48"
48" 60"
60" 66"
3/8"
25 3/4"
18" MIN.
13" MAX.
30" MIN.
A
Ce manuel convient aux modèles suivants
17
Table des matières
Autres manuels American Range Plaque

American Range
American Range PERFORMER AROBSCT-424 Manuel utilisateur

American Range
American Range ARR-4842GRDF Manuel utilisateur

American Range
American Range ARR-304DF Manuel utilisateur

American Range
American Range LEGEND Series Manuel utilisateur

American Range
American Range ARSCT-486GD Manuel utilisateur