American Dynamics RCTT16BE Manuel utilisateur

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
1 of 15
View Manager 16 Plus
Enhanced TOUCH
TRACKER
®
Installation Guide
A
B
C
D
123
456
789
0
Peel
Info
On
Output
Off
Clear
Menu
Iris
CloseOpen
Flip
View
Pattern
Repeat
Pattern
Seq
Previou
s
Next
RCTT16BE
Contents
About this Guide................................................................... 1
Changes from Prior Version ......................................... 1
TOUCH TRACKER Installation................................................. 2
Installation Diagrams............................................................ 3
Installation Notes .......................................................... 3
Enhanced TOUCH TRACKER with Multiplexer
(DB25 connection)........................................................ 4
Enhanced TOUCH TRACKER with Multiplexer
(RJ11 connection) ........................................................ 5
Enhanced TOUCH TRACKER with Quad Splitter
(RJ45 connection) ........................................................ 6
Enhanced TOUCH TRACKER with RVQX7X Quad
Splitter........................................................................... 7
Enhanced TOUCH TRACKER with Intellex 1.x ................ 8
Enhanced Touch Tracker with Intellex 2.0 ................... 9
Enhanced Touch Tracker with Intellex 2.1 ................. 10
Enhanced TOUCH TRACKER and Duplex Remote Panel
(RVDRP)..................................................................... 11
Enhanced TOUCH TRACKER with Domes Only
(No External Unit) ....................................................... 12
Configuring the External Device......................................... 13
Setting Primary and Secondary Unit.................................. 13
Additional Touch Tracker Tasks......................................... 14
Displaying System Information................................... 14
Performing the SensorNet Ping Test.......................... 14
Resetting a Dome ....................................................... 14
Adjusting V-Phase ...................................................... 14
Specifications ..................................................................... 15
SensorNet................................................................... 15
Enhanced Touch Tracker ........................................... 15
Declarations ....................................................................... 15
Regulatory Compliance .............................................. 15
© 2005 Sensormatic Electronics Corp.
About this Guide
These installation instructions explain how to setup
the VM16+ Enhanced TOUCH TRACKER. Other relat-
ed documents are:
•System Operator's Manual, 8000-2653-01
•Quick Reference Guide, 8000-2654-01
If you need assistance...
Contact your Sensormatic Representative.
Changes from Prior Version
Significant changes are noted with revision bars in
margins.
•Updated bill of materials for RVEIMKITE.
•Moved location of installation diagrams in
document.
•Updated wiring diagrams for Intellex units and
Duplex Remote Panel.
•Updated Regulatory Compliance statement.

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
2 of 15
!
TOUCH TRACKER Installation
RVEIMKITE TOUCH TRACKER Installation Kit
Part Number Description Quantity
6003-0047-01 CBL/A, MDR, 14',8 C,CROSS-P'D 1
5899-0004-102 SCR, TCUT, M2.9X9.5, PHP, ST,Z,T1 1
2880-0083-01 ANCH, PL, W/O SCR, 3/4L,#4-#6-#8 2
2816-7634-44 SCR, TYP AB, PHP, ST, Z, 8X1 2
2109-0254-04 CON, P, EUR,.2C,28-12G,1X5P 1
2141-0002 LUG, SPADE, INSUL, 22-168 3
6002-0024-01 CBL, 3C, 18G, CM 16.5
0649-0006-02 BAG PLASTIC 4 X 6 1/2 4MIL 1
0649-0006-04 BAG PLASTIC 8 X 10 4 MIL THK 1
2450-0008-01 LBL, BLNK, PAP, THERM, 89X76M, RL 1
3600-0032-01 PRINTING SPEC, LABEL 0
0300-1000-01 INTERCONNECT BOX, TOUCH TRACK 1
6003-0107-01 CBL/A, QUAD, SW, INTFCE 1
2125-0007-02 HOOD, D, 9P, EMI/RFI, 1/4 D CBL 1
2130-0021-01 CON, D,P, HSG, 9P, SSI 1
2103-0092-01 CONT, P, D, 26-22,AU 3
0650-1079-01 CABLE ASSY, VM8 TOUCHTRACKER/VI 1
8000-2672-01 INSTL INSTRS, TT ENHANCED 1
0649-0006-06 BAG, PLASTIC 12-1/2 X 14X4MIL 1
8000-2653-01 SYS OPERATOR'S MANUAL, VM16 1
8000-2654-01 SYS QUICK GUIDE, VM16 1
8000-1370-02 TTRACKER STRAIN RELIEF INSTR 1
6003-0108-01 CBL/A, VM16+/TNG, MUX/INTFCE 1
RPNR00 CBL/A, RS-232, 10', DB9F-DB9M 1
For Quad Splitter (RVQX7X) with DB9 Connector
These additional parts are required.
PN Description Quantity
2125-0007-02 DB9 Hood 2
2103-0092-02 DB9 Female contact pins 5
2103-0092-01 DB9 Male contact pins 5
2130-0021-01 DB9 Male Connector 1
2130-0022-01 DB9 Female Connector 1
WARNING: RISK OF ELECTRIC
SHOCK! Disconnect AC Power to
the switch.
CAUTION-Electrostatic Sensitive
Device: Follow proper handling
procedures to prevent component
failure.
Note: Prior to installing the Enhanced TOUCH
TRACKERS, identify the type of external unit that will
connect to the Enhanced TOUCH TRACKER, if
applicable. Build any cables that are required.
Refer to the Installation Diagrams starting on
page 3 for specific instructions.
1. Terminate the External Interconnect Module
(EIM) at the end of the SensorNet network. If
more than one Enhanced TOUCH TRACKER
controller will be installed, one TOUCH
TRACKER's EIM will be terminated; the other EIM
will be unterminated. Refer to the appropriate
wiring diagram for your configuration.
2. Mount each EIM on a wall or other surface
within 3m (10 feet) of the Touch Tracker
controller.
3. Connect the power transformer and SensorNet
cable to J3 on each EIM. If two Touch Trackers
will be installed, connect the SensorNet cable
from the first EIM to the second EIM.
4. Depending on the external unit that will be
attached to your system, connect the
appropriate cable to the DB9 connector on the
EIM. Refer to the appropriate wiring diagram for
additional details.
5. Connect the data cable from J1 on the Primary
TOUCH TRACKER's EIM to the remote port on the
external unit. Refer to the appropriate wiring
diagram for additional details.
6. Connect the modular cable from J2 on each
EIM to the TOUCH TRACKER controller.
7. Connect the SensorNet cable from the dome to
the first EIM. Refer to the appropriate wiring
diagram for additional details.
8. Plug in the power transformer into a grounded,
3-wire receptacle.
Note: If the keypad and backlighting do not
illuminate when power is applied, unplug each
power transformer and repeat steps 3 through 8.
Depending on system configuration, it may take up
to 2 minutes for the Enhanced TOUCH TRACKER to
come completely online.
Continue with Configuring the External Device.
!

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
3 of 15
Installation Diagrams
The following pages illustrate the installation of the
VM16+ Enhanced Touch Tracker in the following
configurations:
Enhanced Touch Tracker with Multiplexer
(DB25 connection)................................................4
Enhanced Touch Tracker with Multiplexer
(RJ11 connection) ................................................5
Enhanced Touch Tracker with Quad Splitter
(RJ45 connection) ................................................6
Enhanced Touch Tracker with RVQX7X Quad
Splitter ...................................................................7
Enhanced TOUCH TRACKER with Intellex 1.x ...... 8
Enhanced Touch Tracker with Intellex 2.0.........9
Enhanced Touch Tracker with Intellex 2.1.......10
Enhanced Touch Tracker and Duplex Remote
Panel (RVDRP) ...................................................11
Enhanced TOUCH TRACKER with Domes Only (No
External Unit) ......................................................12
Refer to the appropriate diagram when connecting
the Enhanced Touch Tracker.
Installation Notes
•Depending on configuration, two Enhanced
TOUCH TRACKERS may be installed. Terminate
E1 on the EIM that is on the end point of the
SensorNet Network.
•The maximum combined SensorNet cable
length is 1000 m (one km or 3000').
•J-Box and dome wiring information is included
for information purposes only. Refer to the
J-Box or dome installation instructions for
complete wiring information.

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
4 of 15
Enhanced TOUCH TRACKER with Multiplexer (DB25 connection)
COLOR
Orange 1HostA
Yello w 2 Host B
Orange Auxiliary A
Yello w 4 Auxiliary B
PIN FUNCTION COLOR
Orange 1SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
PIN FUNCTION
5 Ground
2 Tx
DB9M
COLOR
BLACK 14 Ground
25 RxRED
DB25M
Your system supports up to
2 controllers. Terminate E1
on the EIM that is on the
end point of the SensorNet
Network.
The maximum combined
SensorNet cable length is
1000 m (3000').
Connect to
Remote
DB25F

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
5 of 15
Enhanced TOUCH TRACKER with Multiplexer (RJ11 connection)
COLOR
BLACK 5
2
GROUND
TRANSMIT
RED
PIN FUNCTION
COLOR
Orange 1Host A
Yellow 2Host B
Orange Auxiliary A
Yellow 4 Auxiliary B
PIN FUNCTION COLOR
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
PIN FUNCTION
To D ome
Refer to instructions
included with device.
Your system supports up to
2 controllers. Terminate E1
on the EIM that is on the
end point of the SensorNet
Network.
The maximum combined
SensorNet cable length is
1000 m (3000').

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
6 of 15
Enhanced TOUCH TRACKER with Quad Splitter (RJ45 connection)
COLOR
5
TRANSMIT
GROUND
RED
ORANGE
PIN FUNCTION
COLOR
GREEN 2
5
TRANSMIT
GROUNDORANGE
PIN FUNCTION
COLOR
GREEN 5
2
RED
ORANGE
PIN
COLOR
Orange 1Host A
Yellow 2Host B
Orange Auxiliary A
Yellow 4 Auxiliary B
PIN FUNCTION COLOR
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
PIN FUNCTION
To Dome
Refer to instructions
included with device.
The maximum combined
SensorNet cable length is
1000 m (3000').
TERMINATED
Only one Touch Tracker
may be installed with the
dual page Quad Splitter.
This EIM must be
terminated.

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
7 of 15
Enhanced TOUCH TRACKER with RVQX7X Quad Splitter
COLOR
Orange 1HostA
Yellow 2 Host B
Orange Auxiliary A
Yellow 4 Auxiliary B
PIN FUNCTION
EIM DB9M
2 Tx
5 Ground
2 Rx
1 Ground
COLOR
Orange 1 SensorNet A
White 228Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
PIN FUNCTION
To Dome
Refer to instructions
included with device.
PART QTY PN
DB9 Hood 2 2125-0007-02
DB9 Female contact pins 5 2103-0092-02
DB9 Male contact pins 5 2103-0092-01
DB9 Male Connector 1 2130-0021-01
DB9 Female Connector 1 2130-0022-01
Only one Touch Tracker may
be installed with the Quad
Splitter. This EIM must be
terminated.
TERMINATED
The maximum combined
SensorNet cable length is
1000 m (3000').

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
8 of 15
Enhanced TOUCH TRACKER with Intellex 1.x
J-B ox #1
EIM #1
DB9M RJ45
RJ45
ASSY
0301-0340-01 REV-
3 2 1
TERMINATED
DB9F
P1
P2
P3
P4
P5
P6 P8
Primary
Touch Tracker
Intellex 1.x
(with DB9 Connector)
24 Vac A
24 Vac B
Ground
Straight-Thru Cable
PN: RPNR00
E1
To Dome
Refer to instructions
included with device.
5 4 3 2 1
Only one Touch Tracker
may be installed with
Intellex. This EIM must
be terminated.
DB9 Connector
Straight-Thru Cable Wiring
EIM DB9F COM 1
2 Tx 2 Rx
3 Rx 3 Tx
5 Ground 5 Ground
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
The maximum combined
SensorNet cable length
is 1000m (3000’).

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
9 of 15
Enhanced Touch Tracker with Intellex 2.0
J-B o x #1
EIM #1
DB9M RJ45
RJ45
ASSY
0301-0340-01 REV-
3 2 1
Terminate d
DB9F
P1
P2
P3
P4
P5
P6 P8
Primary
Touch Tracker
Intellex 2.0
(with DB9 Connector)
24 Vac A
24 Vac B
Ground
Straight-Thru Cable
PN: RPNR00
E1
To Dome
Refer to instructions
included with device.
5 4 3 2 1
Only one Touch Tracker
may be installed with
Intellex. This EIM must
be terminated.
COM 2
DB9 Connector
COM 1
Straight-Thru Cable Wiring
EIM DB9F COM 2
2 Tx 2 Rx
3 Rx 3 Tx
5 Ground 5 Ground
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
The maximum combined
SensorNet cable length
is 1000m (3000’).

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
10 of 15
Enhanced Touch Tracker with Intellex 2.1
J-Box #1
DB9M
P1
P2
P3
P4
P5
P6 P8
Intellex 2.1
(with DB9 Connector)
DB9F
Straight-Thru Cable
PN: RPNR00
To Dome
Refer to instructions
included with device.
RJ45
RJ45
Primary
Touch Tracker
Secondary
Touch Tracker
COM 1 DB9 Connector
Call monitor feature board
is used if Secondary Touch
Tracker is installed.
Your system supports up to
2 controllers. Terminate E1
on the EIM that is on the
end point of the SensorNet
Network.
Straight-Thru Cable Wiring
EIM DB9F COM 2
2 Tx 2 Rx
3 Rx 3 Tx
5 Ground 5 Ground
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
The maximum combined
SensorNet cable length
is 1000m (3000ft).
Autres manuels pour RCTT16BE
1
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels American Dynamics Télécommande
Manuels Télécommande populaires d'autres marques

Panasonic
Panasonic EUR7622KB0 Manuel utilisateur

Bang & Olufsen
Bang & Olufsen Beo4 Manuel utilisateur

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Manuel utilisateur

Multiplex
Multiplex PROFI TX 9 Manuel utilisateur

One Remote
One Remote RMB4 Manuel utilisateur

FUTABA
FUTABA 9ZAP - PART2 Manuel utilisateur