Alpha Technologies LPR48-300 Manuel utilisateur

Your Power Solutions Partner
LPR48-300
Installation & Operation Manual
Part # 0120049-J0
Effective: 01/2018
member of The Group™


LPR48-300
For technical support, contact Alpha Technologies:
Canada and USA: 1-888-462-7487
International: +1-604-436-5547
Copyright
Copyright © 2018 Alpha Technologies Ltd. All rights reserved.
Alpha is a registered trademark of Alpha Technologies.
No part of this documentation shall be reproduced, stored in a retrieval system, translated, transcribed, or transmit-
ted in any form or by any means manual, electric, electronic, electromechanical, chemical, optical, or otherwise
without prior explicit written permission from Alpha Technologies.
This document, the software it describes, and the information and know-how they contain constitute the proprietary,
confidential and valuable trade secret information of Alpha Technologies, and may not be used for any unauthorized
purpose, or disclosed to others without the prior written permission of Alpha Technologies.
The material contained in this document is for information only and is subject to change without notice. While
reasonable efforts have been made in the preparation of this document to assure its accuracy, Alpha Technologies
assumes no liability resulting from errors or omissions in this document, or from the use of the information contained
herein. Alpha Technologies reserves the right to make changes in the product design without reservation and with-
out notification to its users.
Alpha shall not be held liable for any damage or injury involving its enclosures, power
supplies, generators, batteries, or other hardware if used or operated in any manner or
subject to any condition inconsistent with its intended purpose, or if installed or oper-
ated in an unapproved manner, or improperly maintained.
Photographs contained in this manual are for illustrative purposes only. These photo-
graphs may not match your installation.
NOTE:
Operator is cautioned to review the drawings and illustrations contained in this manual
before proceeding. If there are questions regarding the safe operation of this powering
system, contact Alpha Technologies or your nearest Alpha representative.
NOTE:
NOTE:

0120049-J0 Rev A
2

3
0120049-J0 Rev A
Table of Contents
1. Safety....................................................................................................................................5
1.1 Safety Symbols .......................................................................................................................... 5
1.2 General Safety ........................................................................................................................... 5
1.3 Mechanical Safety...................................................................................................................... 5
1.4 Electrical Safety ......................................................................................................................... 6
2. Product Overview..................................................................................................................7
2.1 Scope of the Manual .................................................................................................................. 7
2.2 Introduction ................................................................................................................................ 7
2.3 Part Number............................................................................................................................... 7
2.4 Product Features ....................................................................................................................... 8
3. Product Specications ..........................................................................................................9
4. Inspection............................................................................................................................10
4.1 Pre-installation Requirements.................................................................................................. 10
4.2 Packing Materials..................................................................................................................... 10
4.3 Returns for Service .................................................................................................................. 10
4.4 Check for Damage ................................................................................................................... 10
4.5 General Receipt of Shipment................................................................................................... 10
5. Installation...........................................................................................................................11
5.1 Safety Precautions....................................................................................................................11
5.2 Tools Required ..........................................................................................................................11
5.3 Module Preparation/Mounting...................................................................................................11
6. Wiring Connections.............................................................................................................12
6.1 DC Input and Output Connectors............................................................................................. 12
6.2 LPR Cable Kit .......................................................................................................................... 12
7. Initial Start Up .....................................................................................................................14
7.1 Normal Mode of Operation....................................................................................................... 14
7.2 Reverse Polarity Protection ..................................................................................................... 14

0120049-J0 Rev A
4
8. Warranty and Service Information ......................................................................................15
8.1 Technical Support .................................................................................................................... 15
8.2 Warranty................................................................................................................................... 15
8.3 Return of Material ................................................................................................................... 15
8.4 Service Centers ....................................................................................................................... 15
9. Acronyms and Denitions ...................................................................................................16
10. Certication.......................................................................................................................17

5
0120049-J0 Rev A
1. Safety
SAVE THESE INSTRUCTIONS: This manual contains important safety instructions that must
be followed during the installation, servicing, and maintenance of the product. Keep it in a safe place. Review the
drawings and illustrations contained in this manual before proceeding. If there are any questions regarding the safe
installation or operation of this product, contact Alpha Technologies or the nearest Alpha representative. Save this
document for future reference.
1.1 Safety Symbols
To reduce the risk of injury or death, and to ensure the continued safe operation of this product, the following sym-
bols have been placed throughout this manual. Where these symbols appear, use extra care and attention.
The use of ATTENTION indicates specic regulatory/code requirements that may affect the
placement of equipment and /or installation procedures.
NOTE:
A NOTE provides additional information to help complete a specic task or procedure.
Notes are designated with a check mark, the word NOTE, and a rule beneath which the
information appears.
WARNING!
WARNING presents safety information to PREVENT INJURY OR DEATH to personnel.
Warnings are indicated by a shock hazard icon, the word WARNING, and a rule beneath
which the information appears.
CAUTION!
CAUTION indicates safety information intended to PREVENT DAMAGE to material or
equipment. Cautions are designated with a yellow warning triangle, the word CAUTION,
and a rule beneath which the information appears.
HOT!
The use of HOT presents safety information to PREVENT BURNS to the technician or
user.
1.2 General Safety
WARNING!
This system is designed to be installed in a restricted access location that is inacces-
sible to the general public.
1.3 Mechanical Safety
• Power supplies can reach extreme temperatures under load.
• Use caution around sheet metal components and sharp edges.

0120049-J0 Rev A
6
1.4 Electrical Safety
WARNING!
WARNING!
Before working with any live battery or power system, follow these precautions:
a. Remove all metallic jewelry, such as watches, rings, metal rimmed glasses, or necklaces.
b. Wear safety glasses with side shields at all times during the installation.
c. Use OSHA approved insulated hand tools.
Lethal voltages are present within the power system. Always assume that an electrical
connection or conductor is energized. Check the circuit with a voltmeter with respect to
the grounded portion of the enclosure (both AC and DC) before performing any installa-
tion or removal procedure.
• Do not work alone under hazardous conditions.
• A licensed electrician is required to install permanently wired equipment. Hazardous voltages are present at the
input of power systems. Ensure that the utility power is disconnected and locked out before performing any
installation or removal procedure.
• Ensure that no liquids or wet clothes come into contact with internal components.
• Hazardous electrically live parts inside this unit are energized from the batteries even when the AC input power is
disconnected.
Hazardous voltages are present at the input of power systems. The DC output from rec-
tiers and batteries, though not dangerous in voltage, has a high short-circuit current
capacity that may cause severe burns and electrical arcing.

7
0120049-J0 Rev A
2. Product Overview
2.1 Scope of the Manual
This instruction manual explains the installation and interconnection of Alpha Technologies’ LPR48-300 down con-
verter system. To aid with installation, frequent reference is made to the drawings located at the rear of the manual.
2.2 Introduction
The LPR48-300 is a compact, sealed, standalone, RFT-V line powering down-converter unit designed for remote
line powering applications using +/- 190Vdc (RFT-V circuit) over twisted copper pairs. The LPR48-300 provides two
regulated nominal -48Vdc outputs from four twisted copper pair inputs, with maximum power of 300W.
Line Powering Network (a.k.a. Express, Simplex, Remote, Centralized) is a method of distributing energy over the
copper network. Multiple twisted-pair copper is used to distribute 100VA limited power source at ±190Vdc. The indi-
vidual, isolated inputs are terminated at a remote end and converted back to a -48Vdc supply.
Power holdup capabilities are incorporated into the LPR48-300 to provide at least 100 millisecond of backup for a
300W load. The holdup prevents potential lengthy customer communication outages due to remote node resetting
caused by line surges and ensure maximum reliability.
See the Features section for more information. The Specifications Section of this manual, details the electrical rat-
ings.
2.3 Part Number
This product is available to order under the following part numbers:
LPR48-300 and LPR Cables 0370445-001
Figure 1 — Front view of the LPR48-300

0120049-J0 Rev A
8
2.4 Product Features
Output Power
Each of the four isolated converters on each LPR48-300 module has a maximum output capacity of 75W (for a total
capacity of 300W per module). The power output is a function of the input voltage into each converter. Proper net-
work engineering and copper pair sizing is a requirement for meeting the power demand of the load.
Current Limit
The current limiting function provides a primary response to output overload situations.
Input Low Voltage Protection
The converter module is electronically protected from low voltages at the inputs by fault detection circuitry. If the
input to the converter module falls below the lower DC input limit (see Specifications), the module will shut down.
Reverse Polarity Protection
The converter design has incorporated reverse polarity protection from the connection to a power source on the
input. This prevents damage to the converter circuitry if a reverse connection is made.
Table des matières
Autres manuels Alpha Technologies Convertisseur de média

Alpha Technologies
Alpha Technologies CXPS 24-48-i Manuel utilisateur

Alpha Technologies
Alpha Technologies LPR12/48-150-IP68 Manuel utilisateur

Alpha Technologies
Alpha Technologies CSM46 Manuel utilisateur

Alpha Technologies
Alpha Technologies CXDF24482KW Manuel utilisateur

Alpha Technologies
Alpha Technologies CXDF 48-24Vdc/2kW Manuel utilisateur

Alpha Technologies
Alpha Technologies CXDF 48-24/2kW Manuel utilisateur

Alpha Technologies
Alpha Technologies CXDF 24-48/2kW Manuel utilisateur
















