Alpha IP HAP 21001 Manuel utilisateur

ENGNORSWE DANFINPOLRUS
HAP 21001
132141.1628
Alpha IP

2
POL RUSFINDAN SWENORENG
ENG 4
2
NORDAN 14
FIN 24
SWE 34
POL 44
RUS 54

3
ENGNORSWE DANFINPOLRUS
1x 1x1x
2x
2x
3 x 32 mm

4
POL RUSFINDAN SWENORENG
ENG
DEU
DEU 4
1 About these instructions 5
1.1 Validity, storage and forwarding of
the instructions 5
1.2 Symbols 5
2 Safety 5
2.1 Intended use 5
2.2 Safety notes 6
3 Function 7
3.1 Alpha IP app 7
3.2 Downloading the Alpha IP app 7
4 Device overview 8
4.1 Front and back side 8
4.2 Technical data 8
5 Commissioning 9
5.1 Device set-up 9
6 Installation 10
7 Displays 10
7.1 Status displays 10
7.2 Error indications 11
8 Cleaning 11
9 Restoring factory settings 11
10 Radio operation 12
10.1 Transmission limit (duty cycle) 12
Contents
11 Decommissioning 12
12 Disposal 12

5
ENGNORSWE DANFINPOLRUS ENG
1 About these instructions
1.1 Validity, storage and forwarding of the instruc-
tions
1.2 Symbols
The following symbols are used in this manual:
Note:Identifies important or useful information
ÖPreconditions
9Result from an action
• List without fixed order
1., 2. List with fixed order
These instructions apply to the Alpha IP Access Point HAP 21001.
These instructions include information necessary for the commis-
sioning. These instructions must the read completely and thor-
oughly before commencing any work with the device. These in-
structions must be kept and to be handed over to future users.
2 Safety
2.1 Intended use
The Access Point HAP 21001 is a component of the Alpha IP Sys-
tem and serves
• for installation in environments of residential use,
• as a central unit to connect the system to smart phones via
the Alpha IP cloud,
• for the wireless communication in the Alpha IP network.
• for the configuration and operation of the Alpha IP system
and the associated components,
• for the remote access to connected components
Every other use, modification and conversion is expressively for-
bidden. Improper use leads to dangers the manufacturer cannot
be held liable for and will exempt guarantees and liabilities.
Safety
These instructions as well as constantly up-to-date addi-
tional Alpha IP system information can be found under
www.alphaip.de.

6
POL RUSFINDAN SWENORENG
ENG
2.2 Safety notes
All safety notes in these instructions must be observed in order to
avoid accidents with personal damage or property damage. No
liability is assumed for personal damage and property damage
caused by improper use or non-observance of the danger notes.
In such cases any warranty claim is invalid. There is no liability for
consequential damages!
• Only the supplied power supply unit (5 V DC/550 mA) may be
used for the power supply of the device.
• Only use the device if it is in flawless state.
• Only connect the device to a well accessible power outlet.
• Pull the power cord off the power outlet in case of danger.
• Observe the performance limits of the device and its environ-
mental conditions.
• Lay the cables of connected consumers in a way that they do
not lead to dangers (e. g. trip hazards) for persons and pets.
• Only operate the device in a dry and dust-free environment.
• Do not expose the device to the influence of humidity, vibra-
tion, continuous solar radiation or other types of radiation,
coldness or mechanical load.
• Ensure that children do not play with this device or its packag-
ing. Children must be monitored if necessary.
About these instructions

7
ENGNORSWE DANFINPOLRUS ENG
3 Function
The Access Point HAP 21001 is the central system unit of the Al-
pha IP Systems. The HAP 21001 offers cloud-controlled world-
wide access via smart phone app and ensures the software up-to-
dateness via automatic system updates.
Configuration and the operation of the HAP 21001 and of con-
nected Alpha IP components can be performed comfortably and
individually via the Alpha IP app on your smart phone. The pos-
sible function range depends on the used system components.
Communication is performed via the Alpha IP cloud with the
Homematic IP (HmIP) radio protocol. Radio transmission is real-
ised on a non-exclusive transmission path; thus, interference can-
not be completely excluded. Interference can be caused e. g. by
switching processes, electric motors or defective electric applianc-
es. (See page 12, Notes on radio operation)
The range inside buildings can be strongly different from
the range in open air.
Function
3.1 Alpha IP app
The entire Alpha IP system is set up and controlled with the Alpha
IP app. The Alpha IP app allocates connected components to the
rooms. The set-up rooms, components and all information are
displayed in a clearly structured way.
3.2 Downloading the Alpha IP App
The Alpha IP app is available to download free of charge for
Android from version 4.4 and for iOS from version 7. The Alpha
IP app is available in the Google Play Store (for Android smart
phones) and in the App Store (for iPhones).

8
POL RUSFINDAN SWENORENG
ENG
4 Device overview
Device overview
4.1 Front and back side
A
LAN
F
G
B
E
D
C
(A) System key and LED
(B) QR code and device number (SGTIN)
(C) Screw holes
(D) Mains connection
(E) Connection of plug-in power supply
(F) Network cable (scope of delivery)
(G) Plug-in power supply (scope of delivery)
Front side
Back side
4.2 Technical data
Short designation of the device HAP 21001
Supply voltage
Power supply unit, primary
side (input)
Power supply unit, secondary
side (output)
100 V-240 V/50 Hz
5 V DC
Power consumption of plug-in
power supply unit
max. 1.5 W
Power consumption max. 500 mA
Standby power consumption 1.1 W
Protection type IP 20
Ambient temperature 5 to 35 °C
Dimensions (W x H x D) 118 x 104 x 26 mm
Weight 153 g
Radio frequency 868.3 MHz/869.525 MHz
Receiver category SRD category 2
Typical radio range 400 m (in open air)
Duty cycle < 1 % per h/< 10 % per h
Network 10/100 Mbit/s, Auto-MDIX
Guidelines 2014/53/EU Radio installa-
tions
2014/30/EU EMC
2011/65/EU RoHs

9
ENGNORSWE DANFINPOLRUS ENG
5 Commissioning
5.1 Device set-up
1. Download the Alpha IP app and install it on your smart phone.
2. Open the Alpha IP app on your smart phone. The installation
is guided by an installation wizard in the app.
3. Connect the Access Point to the router using the supplied net-
work cable (see page 8 pos. D).
4. Establish the power connection using the supplied plug-in
power supply (see page 8 pos. E).
5. Scan the QR code (see page 8 pos. B) on the back of the Ac-
cess Point.
As an alternative, enter the device number (SGTIN) of the
Access Points manually in the app.
Commissioning
The commissioning of the Alpha IP system is described step by
step in this section. Further Alpha IP devices can be added and
integrated into the Alpha IP System after the commissioning of
the Access Point.
(i) The Alpha IP App is available for iOS and Android for a free
download in the respective app store.
(ii) An Internet connection is necessary for commissioning ans
operation.
6. As soon as the LED in the system key (see page 8 pos. A) lights
continuously in blue, confirm this in the app.
In case of other flashing behaviour, follow the instructions
in the app or see error descriptions in section 7.
9The Access Point will be registered to the server; this may last
several minutes.
7. Press the system key (see page 8 pos. A) after successful regis-
tration for confirmation.
9The teach-in process will be performed.
9The Alpha IP Access Point is ready for operation.

10
POL RUSFINDAN SWENORENG
ENG
6 Installation
The ALPHA IP Access Point must be positioned with a
minimum distance of 50 to your WLAN router.
The Alpha IP Access Point can be positioned on a table or installed
to a wall.
1. For wall installation drill two holes with a diameter of 5 mm
and a distance of 7.5cm.
2. Insert the supplied dowels into the bores.
3. Screw in the supplied screws so that they protrude 4 mm from
the wall.
4. Hang the Alpha IP Access Point onto the screws.
7 Displays
7.1 Status displays
Display Meaning Meaning
Continuous
lighting in
orange
Starting process Let the process finish.
Observe the flashing
behaviour.
Quick flashing
in blue
Connection
establishment to
the server
Wait until the the
process is finished.
Continuous
lighting in blue
Standard opera-
tion, connection
to server OK
Operation can be
continued.
Long lighting in
green
Process confirmed Confirmation of per-
formed set-up.
Alternate long
and short flash-
ing in orange
Updating Wait until the the
process is finished.
InstallationDisplays /
Autres manuels pour HAP 21001
2
Table des matières
Langues :
Autres manuels Alpha IP Point d'accès sans fil
Manuels Point d'accès sans fil populaires d'autres marques

D-Link
D-Link DWL-2100AP - AirPlus Xtreme G Manuel utilisateur

Ubiquiti
Ubiquiti NanoStation NSM2 Manuel utilisateur

Cisco
Cisco Aironet 1550 Series Manuel utilisateur

Aruba
Aruba IAP-335 Manuel utilisateur

Advantek Networks
Advantek Networks AWN-AP-54MR Manuel utilisateur

IP-COM
IP-COM AP355 Manuel utilisateur