1. Contact Information
Alpha ESS Australia Pty. Ltd.
Unit 1, 2 Ralph Street
Alexandria NSW 2015
AUSTRALIA
+61 1300 968 933
www.alpha-ess.com.au
1.1 Copyright Declaration
This manual is under the copyright of Alpha ESS Co., Ltd with all rights reserved.
Please keep the manual properly and operate in strict accordance with all safety
and operating instructions in this manual. Please do not operate the product before
reading through the manual.
1.2 Version Information
Version Date Content
1.0.0 May 2022 Owner’s Manual
CONTACT


Owner’s Manual5
CONTENTS
1 Contact Information
1.1 Copyright Declaration
1.2 Version Information
2 Installation & Commissioning Checklist
2.1 Induction Requirements
3 Important Safety Precausions
4 Smile B3 Plus
4.1 TechnicalSpecications
4.2 Operating Priciple
4.3 System Operation
4.4 System Operation Status
5 Maintenance
5.1 Function Checks
5.2 System Faults/Errors
6 System Monitoring
6.1 Wi-FiConguration
6.2 System Registration
6.3 Alpha ESS App Features
7 Emergency Situations
7.1 Emergency Handling Plan
7.2 Fire
7.3 Leaking Batteries
7.4 Wet Batteries
7.5 Damaged / Decommissioning Battery
8 Warranty Conditions
9 Safety Data Sheets
3
3
3
4
5
8
12
13
14
14
15
16
17
17
18
18
20
20
24
24
24
24
25
25
26
32

6
INSTALLATION &COMMISSIONING
2. Installation & Commissioning Checklist (For Installers Only)
Following the SMILE B3 Plus installation, you must ensure the below checklist is
completed and a record of the same is shared with your system provider. It’s also
recommended to retain records of the equipment installed.
No. Items Description
1System Provider (Contact details)
2Primary Batteries Model Number - SMILE-B3 PLUS (5.04
kWh)
S/N –
3Secondary Batteries Model Number – SMILE-BAT-5P (5.04
kWh)
Number of batteries -
S/N –
S/N –
S/N –
S/N –
S/N –
4Energy Meters Model Number – ACR10R / DTSU666
Number of Meters –
5Total Battery Storage Capacity (kWh)
6UN Number UN 3480
7Date of Installation & Commissioning
8Firmware Versions
• Inverter
• BMS
9Initial System Settings
• Safety Regulation
• Regional Application Standard
AS 4777.2
Australia A / Australia B / Australia C /
NZ
10 System Verication Grid Status - On Grid Status - Off
Is the Battery Charging? (Y/N) N/A
Is the Battery Discharging? (Y/N)
11 If Backup/UPS is Connected, does
the battery discharge towards
connected loads when Utility grid is
turned off? (Y/N)
12 DC Connections – Is there any high
resistance at the junction of the DC
cables & battery terminals? (Y/N)

Owner’s Manual7
INSTALLATION &COMMISSIONING
2.1 Induction requirements (For Installers Only)
Following the SMILE B3 PLUS installation, ensure that the system owner or
nominated representative is provided the following information:
• Demonstration of the System shutdown & Start-up procedures,
• Introduction to the system manual,
• Explanation of the Alarm/Faults that may arise with the system,
• Contact details of Manufacturer/ system provider,
• Basic System Operation & design principles.
Further, ensure that a copy of the below customer acknowledgement is provided to
the system provider for their installation records.
Customer Acknowledgement
I, ……………………………………(Customer) acknowledge that ………………………………...
(System Provider) have attended my property and conducted the requested work.
Iconrmthattheinstallerattendingmypropertyhascompletedtheinstallation
basedonhis/herrecommendationforthemostefcientenergyproduction,
provided me all the information as per the induction requirements (Section 2.1) and
IconrmthatIhaveagreedtothisinstalllocation.
Customer’s Signature
Date:
Installer’s Signature
Date:

8
SAFETY
3. Important Safety Precautions
This Owner’s Manual contains essential instructions to be followed while operating
the Alpha ESS SMILE B3 PLUS system. Please note the following safety symbols
that appear throughout this document that indicate dangerous conditions, relevant
warnings, and notes to facilitate best results. Improper use of this system poses a
risk of injury or death to the user or third party, as well as damage to the product.
The storage system must always be operated as per the recommendations within
this owner’s manual.
Danger:
Danger to life due to high voltages of battery and electric shock.
• Onlyqualiedpersonnelwhoareequippedwiththesuitablespecialisttraining,
knowledge and experience is permitted to install and debug the system. Before
performing any work on the inverter or battery pack, please disconnect the
inverter from all voltage sources as described in this document.
• The Electrician should always wear the right Personal Protective Equipment
(PPE – Level 1) while operating the Energy Storage system.
• Do not touch any uninsulated DC cables, as this may result in electrical shock
or injury.
• Do not open the Inverter and Battery or modify any of the protective devices.
• Donotdisposeofbatteriesinreasthebatteriesmayexplode.
• Only use the Battery system in its original state, without any unauthorized
modicationsandwhenit’sinproperworkingorder.
• Incorrect operation puts you and others at risk and could cause material
damage and potential injuries.
• Do not use the battery system in potential explosive environments.
• Never block, modify or alter any Electrical protective devices such as AC
Circuit breakers, Isolators or electrical cabling.
• Never attempt to repair the system yourself or using the services of a third-
party electrician as this may result in injury or may void the product warranty.
• Ensure that all relevant local and national regulations are observed, and
authorised electrician is responsible for adhering to these regulations.

Owner’s Manual9
SAFETY
Warning:
Risks of chemical burn electrolyte or toxic gases.
The battery modules installed in the BESS are protected by multiple
Electrical protection devices and can be operated safely during standard
operation. However, there is a potential for the electrolyte leakage from the
battery pack as well as form toxic gases if damaged mechanically or break
down. Therefore, it’s recommended to proceed as follows,
• Do not install the system in extreme low/high temperatures or humidity
exceeding the permitted range.
• Do not place heavy objects on top of the system or mechanically damage the
batteries (by piercing, puncturing or deforming it)
• Do not short circuit the battery module or allow them to come in contact with
metal.
• Do not continue to use the battery module after a short-circuit.
• Do not install the battery pack in the vicinity of any equipment containing
ammablegasesorliquids.
• If the moisture penetrates the system (e.g. due to casing damage), please
do not operate the system and contact Alpha ESS immediately for further
troubleshooting.
• If you come into contact with the electrolyte, please wash affected area with
water immediately, and consult a doctor immediately.
Risk of injury by hoisting or falling system
• Inverters and batteries are heavy and can cause personal injury if the inverter
or battery is improperly lifted or dropped during transport or when attached or
removed from walls.
• Lifting and transporting of SMILE-B3-PLUS/SMILE-BAT-5P must be conducted
by more than 1 person.

10
SAFETY
Symbol Explination
Beware of a danger zone.
This symbol indicates that the product must be additionally grounded if additional
grounding or equipment bonding is required at the installation site.
Beware electrical voltage.
The products operates at high voltages.
Beware hot surface.
The product can get hot during operation.
Danger to life due to high voltages in the inverter, observe a waiting time of 5
minutes.
WEEE designation.
Do not dispose of the product together with household waste, but in accordance
with disposal regulations for electronic waste applicable at the installation site.
Observe the documentation.
Certiedsafety.
The product is TUV-tested and complies with the requirements of the EU Equipment
and Product Safety Act.
CE marking.
The product complies with the requirements of the applicable EU directives.
RCM (Regulatory Compliance Mark)
The product complies with the requirements of the applicable Australian standards.
Autres manuels pour SMILE-B3-PLUS
2
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Alpha ESS Onduleur

Alpha ESS
Alpha ESS PWG2-50K Manuel utilisateur

Alpha ESS
Alpha ESS Storion-SMILE-T10 Manuel utilisateur

Alpha ESS
Alpha ESS Backup Box-PLUS Manuel utilisateur

Alpha ESS
Alpha ESS Storion-SMILE5 Manuel d'instructions

Alpha ESS
Alpha ESS SMILE-T10-HV-INV Manuel utilisateur

Alpha ESS
Alpha ESS SMILE-T10-HV-INV Manuel utilisateur

Alpha ESS
Alpha ESS M4856-S Instructions d'utilisation et d'entretien