Allworx 48x Manuel utilisateur

Allworx 48x
Installation Guide

No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any
form or by any means, electronic, mechanical, photocopy, recording, or otherwise without the prior
written permission of Allworx.
© 2010 Allworx Corp. All rights reserved. Allworx, a wholly owned subsidiary of PAETEC Holding. All other
names may be trademarks or registered trademarks of their respective owners.

48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx, a wholly owned subsidiary of PAETEC Holding. All other names may be trademarks or
registered trademarks of their respective owners.
Version:1. Revised: July 15, 2010
Page i
Table of Contents
1Installation Overview.....................................................................................................................................1
2Unpacking .....................................................................................................................................................2
3Chassis Views...............................................................................................................................................3
4Mechanical....................................................................................................................................................5
4.1 Tabletop Placement..............................................................................................................................5
4.2 Rack Mount...........................................................................................................................................5
4.2.1 Consider When Mounting..................................................................................................................6
4.3 Wall Mount............................................................................................................................................7
5Electrical........................................................................................................................................................9
5.1 Power Connection.................................................................................................................................9
5.2 Chassis Ground ....................................................................................................................................9
5.3 Power-Up Sequence.............................................................................................................................9
5.4 Safe Mode Sequence .........................................................................................................................10
6Server Configuration ...................................................................................................................................11
7Ethernet Connectivity..................................................................................................................................12
8Analog Telephony .......................................................................................................................................13
9T1................................................................................................................................................................14
10 Accessories (Optional)................................................................................................................................15
10.1 Line IN/OUT........................................................................................................................................15
10.2 Terminal Block ....................................................................................................................................15
10.3 Serial Port ...........................................................................................................................................15
11 Physical and Environmental Specifications.................................................................................................16
12 Regulatory Notices......................................................................................................................................17
12.1 FCC Part 68........................................................................................................................................17
12.2 Industry Canada..................................................................................................................................17
12.3 Radio and Television Interference ......................................................................................................18

48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx, a wholly owned subsidiary of PAETEC Holding. All other names may be trademarks or
registered trademarks of their respective owners.
Version:1. Revised: July 15, 2010
Page ii
- This page intentionally left blank -

48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 1
1 Installation Overview
Installation of the Allworx®48x involves the following steps:
1. Unpacking
2. Mechanical Installation
3. Electrical Installation
4. Server Configuration
5. Network Installation
6. Telephony Installation
7. T1 Installation
8. Accessories Installation
Each of these steps will be described in the following sections.

48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 2
2 Unpacking
Open the box and carefully unpack it. Save all shipping and packaging materials. Verify all items against the
parts list shown in Table 1. If any items are missing, contact your dealer or Allworx Customer Support at 866-
255-9679.
Quantity Item Part Number
1 Allworx 48x Server 7502600
1 Power Cord 3000100
1 48x Installation Instructions 5000221
1 Sheet that has 4 Rubber Feet for Table Mounts 4122181
1 Rack and Wall Mount Hardware Kit 4100180
Table 1: Parts List

48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 3
3 Chassis Views Figure 1: Front Chassis View
1 Power switch
Press & Release – Normal shutdown within a few seconds
Press & Hold – Forced shutdown
2 Power LED – Indicates system start up activity
3 Activity LEDs – Green indicates mounted drive; blinking light indicates activity
4 Two (2) USB Host Ports
5 Door relay port
6 RJ-45 10BaseT/100BaseTX Auto-Sensing Auto-MDI/MDIX Local Area, Wide
Area, and Demilitarized Zone (DMZ)*Network Ethernet ports.
7 T1 Ports (A/B)
8 RJ-11 Power Fail analog phone connector
9 RJ-11 loop-start FXO for central office connection (Ports 1-3)
10 RJ-11 FXS ports for inside extensions (Ports 4-8)
11 3.5 mm stereo audio mini jack for music-on-hold (input) and overhead paging
(output)
*Future Feature
9
67
3214
5
810 11

48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 4
Figure 2: Rear Chassis View
12 Air intake vent
13 Terminal block for door relay or paging amplifier
14 Permanent ground connecting screw
15 Air exhaust vent
16 IEC Power cord connector
14 15 16
12 13

48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 5
4 Mechanical
4.1 Tabletop Placement
To install the Allworx 48x on a tabletop or shelf:
1. Remove the four rubber feet from the packaging.
2. Remove the paper backing from each rubber foot.
3. Turn over the chassis and place one foot at each corner on the bottom of the chassis.
4.2 Rack Mount
To mount the Allworx 48x, 1U high rack mount, inside of a standard 19 inch rack:
1. Verify that there is sufficient clearance around the server’s front and rear panels to allow power, network,
and telephony connections.
2. Place the brackets so that the smaller face of the bracket extends away from the front of the unit to
accommodate installation into the rack (See Figure 3).
3. Install the mounting brackets on each side of the server chassis using the four 6-32 flat head screws.
4. Proceed to the Power Connection (Section 5.1) instructions and perform the steps appropriate for your
installation before placing the system into the rack.
5. Install the server into the rack using appropriate hardware.
Figure 3: Rack Mount Bracket Installation

48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 6
4.2.1 Consider When Mounting
•Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration
should be given to installing the equipment in an environment compatible with the maximum ambient
temperature (40°C).
•Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
•Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition
is not achieved due to uneven mechanical loading.
•Circuit Overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
•Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch circuit (e.g.
use of power strips).
Table des matières
Autres manuels Allworx Téléphone

Allworx
Allworx 9202E Manuel utilisateur

Allworx
Allworx 9202 Manuel utilisateur

Allworx
Allworx 9204 Manuel utilisateur

Allworx
Allworx 9224 Manuel utilisateur

Allworx
Allworx 9202E Manuel utilisateur

Allworx
Allworx 9212 Manuel utilisateur

Allworx
Allworx 9204 Manuel utilisateur

Allworx
Allworx 24x Manuel utilisateur

Allworx
Allworx 6x Guide d'installation

Allworx
Allworx 9224 Manuel utilisateur

















