Allmand LSC 2.1 Manuel utilisateur

Not for
Reproduction
LSC 2.1 Display Module
PHONE
FAX
PARTS DEPT. FAX
WEB
(308) 995-4495, (800) 562-1373
(308) 995-5887
(308) 995-4883
www.allmand.com 107020USCN
Revision A
INSTRUCTION MANUAL
MANUAL DE INSTRUCCIONES
MANUEL D'INSTRUCTIONS
Módulo de pantalla de LSC 2.1
Module d'afchage LSC 2.1
en
fr
es

Not for
Reproduction

Not for
Reproduction
TABLE OF CONTENTS
LSC Display Module Instruction Manual
© 2015 Allmand™ Bros., Inc.
i
MAIN OPERATING SCREEN ..................................................................1
Menu Screen .......................................................................................................................................3
Fuel Hours Screen...............................................................................................................................4
Automatic Control Setup Screen ...................................................................................................6
Timed Events Menu Screen.....................................................................................................7
Timed Events Screen.........................................................................................................8
Copy Day Events Screen...................................................................................................9
Block Heater Setup Screen......................................................................................................10
Auto-Mode – Sunset/Sunrise-based Start/Stop Screen...........................................................11
GPS Location Setup Screen....................................................................................................12
System Screen ..............................................................................................................................13
Update Programming Screen ..................................................................................................14
Clock Setup Screen.................................................................................................................15
Day Light Savings Time Setup Screen ..............................................................................16
System Options Screen...........................................................................................................18
Maintenance Screen......................................................................................................................20
Clear Fault ...............................................................................................................................21
Input Diagnostics Screen.........................................................................................................22
Output Diagnostics Screen......................................................................................................23
System Event Log Screen .......................................................................................................24
UTC TIME ZONES..................................................................................25
FAULT MESSAGES.................................................................................29
en

Not for
Reproduction
LSC Display Module Instruction Manual
© 2015 Allmand™ Bros., Inc.
Page intentionally left blank
ii

Not for
Reproduction
LSC 2.1 Display Module
LSC Display Module Instruction Manual
© 2015 Allmand™ Bros., Inc.
1
MAIN OPERATING SCREEN
2
11
1
13
12 3
4
10 9 78 6 5
Figure 1
1 – Fuel Level Gauge
2 – Current Date and Time
3 – Accumulative Engine Run Hours
4 – Engine Coolant Temperature Gauge
5 – Menu Button
6 – Start Button
7 – Glow Plug–On Symbol
8 – Time of Next Event
9 – Time-Start Button
10 – Auto-Start Button
11 – Oil Pressure Gauge
12 – DC Battery Voltage
13 – Fault Message
The orange bar that runs across the top of the Main
Operating screen displays:
• Any applicable fault messages (item 13 in
Figure 1)
• The current date and time (item 2 in Figure 1).
For a list of possible fault messages, see FAULT
MESSAGES.
To change the date and time, see Clock Setup
Screen.
The middle of the Main Operating screen displays:
• Engine oil pressure gauge (item 11 in Figure 1)
• Fuel level gauge (item 1 in Figure 1)
• Engine coolant temperature gauge (item 4 in
Figure 1)
• Battery DC voltage (item 12 in Figure 1)
• Accumulated engine run hours (item 3 in Figure 1)
• The time at which the next start-up or shutdown
will occur (Item 8 in Figure 1)
en

Not for
Reproduction
LSC Display Module Instruction Manual
© 2015 Allmand™ Bros., Inc. 2
The bottom of the Main Operating screen has the
glow plug–on symbol (item 7 in Figure 1) as well as
four buttons.
• Auto-Start button (item 10 in Figure 1): Press the
Auto-Start button to activate the auto-start/stop
program, which will start the engine at or near
sunset and stop the engine at or near sunrise.
Press the Auto-Start button again to turn off the
program. For more information on setting up
the sunrise and sunset times, see Auto-Mode –
Sunset/Sunrise-based Start/Stop Screen.
• Time-Start button (item 9 in Figure 1): Press
the Time-Start button to activate the time-start/
stop program, which will start or stop the engine
at preset times of the day. Press the Time-Start
button again to turn off the program. For more
information on setting up the timed start/stop
program, see Automatic Control Setup Screen.
• Start button (item 6 in Figure 1): Press the Start
button to start the engine. The engine will start
after a 15-second delay, and the display will
change from Start to Stop. Press the Stop button
to stop the engine.
• Menu button (item 5 in Figure 1): Press the Menu
button to make programming changes (see Menu
Screen).

Not for
Reproduction
LSC 2.1 Display Module
LSC Display Module Instruction Manual
© 2015 Allmand™ Bros., Inc.
3
Menu Screen
On the Main Operating screen, press the Menu
button. The Menu screen will appear (see Figure 2).
Figure 2
There are three choices to select from on the Menu
screen:
• Automatic Control Setup (see Automatic Control
Setup Screen)
• System (see System Screen)
• Maintenance (see Maintenance Screen)
• Fuel Hours (see Fuel Hours Screen)
Use the UP and DOWN arrows to move between the
items. Press the Enter button to select an item.
Press the Exit button to return to the Main Operating
screen.
en

Not for
Reproduction
LSC Display Module Instruction Manual
© 2015 Allmand™ Bros., Inc. 4
Fuel Hours Screen
How to navigate to the Fuel Hours screen:
1. On the Main Operating screen, press the Menu
button. The Menu screen will appear.
2. Press the DOWN arrow three times to highlight
Fuel Hours. Press the Enter button. The Fuel
Hours screen will appear (see Figure 3).
NOTE: Fuel hours are an estimate only.
Figure 3

Not for
Reproduction
LSC 2.1 Display Module
LSC Display Module Instruction Manual
© 2015 Allmand™ Bros., Inc.
5en
To change back to the Main Operating screen with the
Fuel Gauge display:
1. On the Fuel Hours screen, press the Menu button.
The Menu screen will appear (see Figure 4).
2. Press the DOWN arrow three times to highlight
Fuel Gauge. Press the Enter button. The Main
Operating screen with the Fuel Gauge display will
appear.
Figure 4

Not for
Reproduction
LSC Display Module Instruction Manual
© 2015 Allmand™ Bros., Inc. 6
Automatic Control Setup Screen
How to navigate to the Automatic Control Setup
screen:
1. On the Main Operating screen, press the Menu
button. The Menu screen will appear.
2. Press the Enter button. TheAutomatic Control
Setup screen will appear (see Figure 5).
Figure 5
There are four items to choose from on the Automatic
Control Setup screen:
• Timed Event Setup (see Timed Events Menu
Screen)
• Block Heater Setup (see Block Heater Setup
Screen)
• Sun-Set Control Setup (see Auto-Mode – Sunset/
Sunrise-based Start/Stop Screen)
• GPS Location Setup (see GPS Location Setup
Screen)
Table des matières
Langues :